Electromagnetic flowmeter
Configurable Models 1 models
Promag P is the preferred sensor for applications with highest requirements in a multitude of industries. Combined with the Promag 10 transmitter for basic applications and direct integration, Promag 10P is dedicated for chemical and process applications with corrosive liquids and high medium temperatures. It will be the preferred solution for customers aiming for minimized cost of ownership. Promag 10P is available as compact or remote version.
Compare

Liquids

Measuring Principle Electromagnetic
Product headline std_productprofile_product_usp_34716_1509006628.
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
Sensor features Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Nominal diameter: max. DN 600 (24"). std_successorproducts_product_differentiating_tech_features_35249_1509523846. std_successorproducts_product_differentiating_tech_features_35251_1509523847.
Transmitter features std_productprofile_product_benefits_34707_1508943674. std_productprofile_product_benefits_34705_1508943673. std_productprofile_product_benefits_34706_1508943673.
2-line display with push buttons. Device as compact or remote version. HART.
Nominal diameter range DN 15 to 600
1/2" to 24"
Wetted materials Liner: PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Volume flow
Max. measurement error Volume flow: ±0,5% o.r. ± 2 mm/s (±0,5% o.r. ± 0,08 in/s)
Measuring range 4 dm3/min to 9600 m3/h (0.5 gal/min to 44000 gal/min)
Max. process pressure PN40
Cl. 300
JIS 20K
AS 2129 Table E
Medium temperature range –40 to +130°C (–40 to +266°F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material DN 15 to 300 (½ to 12"): AlSi10Mg, coated
DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
Transmitter housing material Powder-coated die-cast aluminum
Degree of protection Standard: IP 67 (Type 4X enclosure) for transmitter and sensor
Optional: IP 68 (Type 6P enclosure) for remote version of sensor
Display/Operation 2‐line display with push buttons
Configuration via local display and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/switch output (passive)
Inputs None
Digital communication HART
Power supply DC 11 to 40 V
AC 85 to 250 V (45 to 65 Hz)
AC 20 to 28 V (45 to 65 Hz)
Hazardous area approvals FM
CSA
Product safety CE, C-tick, EAC marking
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Pressure approvals and certificates PED

The Promag P sensor is widely used in various most demanding industries. Combined with the Promag 10 transmitter, which meets basic applications and enables direct integration, Promag 10P is suitable for process applications in the chemical industry and for measuring high-temperature, corrosive media. It is the preferred solution for customers to minimize costs. Promag 10P is available in compact and remote versions.

 

Benefits

Wide range of applications - various wetted materials available

Energy-saving flow measurement - cross-section identical to the pipe, no pressure loss

Maintenance-free - no moving parts

Economical - designed for simple use and direct integration

Safe operation - display module provides easy-to-read process information

Fully compliant with industry standards - IECE/EN/NAMUR

 

Application

Bidirectional measuring principle, independent of pressure, density, temperature and viscosity

Designed for measuring corrosive and high-temperature media in chemical and process applications

Device features

 

Nominal diameter: max. DN 600 (24")

Common process connections

PTFE liner

Two-line display with pushbuttons

Compact or remote version

HART

Spare Parts & Accessories 35

35 spare parts · click to collapse
Order codeDescription
50104751PCB mainboardDetails
50104752PCB main boardDetails
71098237PCB mainboardHE = harsh environmentDetails
71098239PCB mainboardHE = harsh environmentDetails
50104749fuseDetails
50104750fuseDetails
50104745display module with push buttonsDetails
50104754Wiring moduleDetails
71098240wiring moduleHE = harsh environmentDetails
50098018sensor terminal boardUsage: 10/50/51/53/55/400/800Details
71039497sensor terminal boardUsage: 10/50/53/55 HE = harsh environmentDetails
50108138terminal blockKit Terminal Block 10/91WDetails
50094038Terminal compartment cover10/5X/40/8X/93/65/92FDetails
71247838Maintenance cover, separate typeUsage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, GreaseDetails
50094038Terminal compartment cover10/5X/40/8X/93/65/92FDetails
50104746cover with glass windowDetails
50104747blind coverDetails
50103658cable glandDetails
50096840cable glandKit 10 cable glands M20x1,5Details
50098041adapterKit 10 extension M20x1.5/G 1/2"Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
1 models · click to collapse
All documents for this model
6 documents · click to expand
BA

Proline Promag 10 HART Operating Instructions English

HART Rev. 1917 148 pages
Preview
BA

Promag 10 Operating Instructions English

124 pages
Preview
TI

电磁流量测量系统 Chinese

Rev. 1109 36 pages
Preview
TI

Proline Promag 10P Technical Information English

Rev. 1317 36 pages
Preview
TI

Proline Promag 10P English

Rev. 1109 36 pages
Preview
TI

Promag 10 P Technical Information English

28 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Electromagnetic flow meter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was volumetric flow of conductive liquids.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing liner and electrode pairing by conductivity, solids and abrasion.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing liner and electrode pairing by conductivity, solids and abrasion, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no obstruction, so pressure loss is minimal and upkeep low, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Electromagnetic flow meter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Electromagnetic flow meter, focusing on volumetric flow of conductive liquids.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Electromagnetic flow meter specification must therefore cover choosing liner and electrode pairing by conductivity, solids and abrasion.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing liner and electrode pairing by conductivity, solids and abrasion, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no obstruction, so pressure loss is minimal and upkeep low, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Electromagnetic flow meter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Electromagnetic flow meter; the focus is volumetric flow of conductive liquids.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing liner and electrode pairing by conductivity, solids and abrasion.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing liner and electrode pairing by conductivity, solids and abrasion, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no obstruction, so pressure loss is minimal and upkeep low, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Electromagnetic flow meter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Electromagnetic flow meter and the core task is volumetric flow of conductive liquids.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Electromagnetic flow meter cannot be specified generically — it calls for choosing liner and electrode pairing by conductivity, solids and abrasion.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing liner and electrode pairing by conductivity, solids and abrasion, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no obstruction, so pressure loss is minimal and upkeep low.