Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

DTI200 电磁流量计

DTI200 电磁流量计

MAGPHANT

Configurable Models 1 models
The cost-effective, compact limit switch Magphant is an ideal flowmeter for water applications in Utilities. Its reliable measurement with high repeatability allows for univesal and easy use and supports safe process- and plant operation.
Compare

Liquids

Measuring Principle Electromagnetic
Product headline .
Sensor features High plant availability – reliable flow information. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts. Compact, space-saving design. Nominal diameter: DN 15 to 2000 (½ to 80").
Transmitter features Process safety – device self-monitoring and reliable monitoring even with empty piping. Product safety – integrated testing to check correct functioning of the electronics. Easy operation – potentiometer setting of full-scale value. Switch point setting via rotary switch. Current output and relay output.
Nominal diameter range DN15 to DN2000
1/2" to 80"
Wetted materials 1.4435/316L
Measured variables Volume flow
Max. measurement error 2%
Measuring range 0 to 56'550 m3/h
Max. process pressure 0 to 16 bar abs
Medium temperature range -20 to +120°C
(-4 to +248°F)
Ambient temperature range -20...60 °C (-4 to 140°F)
Sensor housing material Die-cast aluminium, epoxy powder coated
Degree of protection IP 66 / NEMA 4X / Type 4X
Display/Operation Test function
Outputs 4 to 20 mA
Relay
Inputs None
Power supply 24 V DC (20...30 V DC)
Hazardous area approvals FM
CSA
Product safety CE, EAC

The economical, compact Magphant flow switch is suited to water applications in utilities. It offers high repeatability, reliably monitors flow, is simple and convenient to operate, and contributes to process and plant safety.

Benefits
High plant availability - reliable flow information
Energy-saving flow measurement: no throttling components, ensuring no pressure loss
Maintenance-free: no moving parts
Process safety: the device has a self-monitoring function and monitors reliably even when the pipe is empty
Product safety: built-in test function ensures the electronics function correctly
Easy operation: electronic setting of the full-scale value

Application areas
Bidirectional measuring principle unaffected by pressure, density, temperature and viscosity
Widely used in various water applications in the utilities sector.
Instrument features
Compact design saves installation space
Nominal diameter: DN 15...2000 (1/2...80")
Can be installed in steel or plastic pipes
Switch point set via rotary switch
Current output and relay output
ATEX, FM, CSA approvals

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: public information from the Endress+Hauser website

Model Name
DTI200-A11A1A 电磁流量计
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Electromagnetic Flow Meter Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Electromagnetic Flow Meter Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Electromagnetic Flow Meter Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Electromagnetic Flow Meter Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.