Technical Data
CompareLiquids
| Measuring Principle | Electromagnetic |
| Product headline | Flowmeter for basic water and wastewater applications with easy-to-use operation concept. Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss. Suitable for elementary measurement tasks such as raw water intake. |
| Sensor features | Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements. International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). International drinking water approvals. Installation length: DVGW/ISO conform. |
| Transmitter features | Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology. System integration with HART, Modbus RS485. Flexible operation with app and optional display. |
| Nominal diameter range | DN 25 to 3000(1 to 120") |
| Wetted materials | Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +160 °F) Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Volume flow, conductivity, mass flow |
| Max. measurement error | Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s) |
| Measuring range | 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d) |
| Max. process pressure | PN 40, Class 300, 20K |
| Medium temperature range | Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) Liner material PTFE: –20 to +90 °C (–4 to +194°F) |
| Ambient temperature range | -40 to 60°C (-40 to 140°F) |
| Sensor housing material | DN 25 to 300 (1 to 12"): AlSi10Mg, coated DN 350 to 2000 (14 to 78"): Carbon steel with protective varnish |
| Transmitter housing material | Polycarbonat; AlSi10Mg, coated |
| Degree of protection | Compact version: IP66/67, type 4X enclosure Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3 |
| Display/Operation | LCD display with touch & auto rotate |
| Outputs | 4-20 mA HART (active/passive), Pulse/frequency/switch output Modbus RS485, 4-20 mA |
| Digital communication | HART, MODBUS RS485, IO-Link |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | CSA, GP, KC |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | CRN, PED |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | Drinking water approvals: ACS, KTW-BWGL, NSF 61, WRAS BS 6920 |
Applications
The Promag W sensor has broad applications thanks to numerous international approvals (e.g. drinking water approval). Compact and remote versions are available for flexible selection. The hardware and software of the Promag W 10 are intuitively designed, greatly simplifying every step of the instrument throughout its entire lifecycle, from design to service, while ensuring Endress+Hauser quality. Heartbeat Technology ensures measurement reliability and verification compliance.
Bidirectional flow measurement, completely unaffected by pressure, density, temperature and viscosity.
Ideal choice for basic measuring tasks such as raw water intake.
Device features
International drinking water approval
IP68, Type 6P degree of protection
Supports HART or Modbus RS485 system integration
Install the app and optional display unit for flexible operation
Benefits
Reliable measurement: zero straight inlet run does not affect highly accurate measured values, no pressure loss
Flexible engineering: sensor with fixed flange or lap-joint flange connections
Broad applications: the sensor is corrosion-protection certified to EN ISO 12944 and supports buried installation or long-term underwater measurement
Higher plant availability: the sensor meets industry-specific requirements
Optimum operability: install the SmartBlue app on a mobile device for direct touchscreen operation
Simple, efficient commissioning: guided instrument configuration presets and on-site setup
Self-verification: uses Heartbeat Technology
Spare Parts & Accessories 52
52 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| XPD0060- | sensor electronics moduleUsage: Promag 10. Consists of: ISEM (sensor electronic module) V316-00. | Enquire |
| XPD0061- | sensor electronics moduleUsage: Promag 10. Consists of: ISEM (sensor electronic module) V316-00. | Enquire |
| XPD0062- | sensor electronics moduleUsage: Promag 10. Consists of: ISEM (sensor electronic module) V313-00. | Enquire |
| XPD0063- | sensor electronics moduleUsage: Promag 10. Consists of: ISEM (sensor electronic module) V313-00. | Enquire |
| XPD0098- | ISEM, standard, IO-Link, Promag 10, nExUsage: Promag 10. Consists of: ISEM (sensor electronic module) V316-00. | Enquire |
| XPD0099- | ISEM, enhanced, IO-Link, Promag 10, nExUsage: Promag 10. Consists of: ISEM (sensor electronic module) V313-00. | Enquire |
| XPD0076- | Electronic insert HART, 24VDC, nEx, polycarbonate, 10Electronic module E400. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0077- | electronic plug-in moduleElectronic module E402. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0078- | Power supply module Modbus, 24VDC, nEx, Polycarb., 10Electronic module E406. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0079- | Modbus electronic module, 100-230VAC, nEx, polycarbonate, 10Electronic module E409. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0080- | HART electronic module, 24 VDC, nEx, Alu, 10Electronic module E401. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0081- | Power module, output moduleElectronic module E403. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0082- | Power module, output moduleElectronic module E408. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0084- | Power module, output moduleElectronic module E411. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module | Enquire |
| XPD0096- | IO-Link, nEx, polycarbonate, 10Electronic module E415. Usage: Promag 10, Promass 10. Consists of: Module cartridge, main electronic mod., connection board. | Enquire |
| XPD0097- | IO-Link, nEx, alu, 10Electronic module E416. Usage: Promag 10, Promass 10. Consists of: Module cartridge, main electronic mod., connection board. | Enquire |
| XPD0087- | Display moduleUsage: Promag 10, Promass 10. Consists of: Display module A400. | Enquire |
| XPD0088- | Display moduleUsage: Promag 10, Promass 10. Consists of: Display module A401. | Enquire |
| XPD0089- | Display moduleUsage: Promag 10, Promass 10. Consists of: Display module A401. | Enquire |
| 71505739 | Memory moduleElectronic storage module unprogrammed Usage: Promag 10. Consists of: S+T-DAT. | Details |
Configurator / Comparison
Source: Endress+Hauserpublic information from the website
Measuring principle video
Click to playDiagnostic codes
Proline Promag W 10(52 条)→数据摘自 Endress+Hauser 操作手册,含状态信号、可能原因与维修指导。
Product Videos
Case Studies
Municipal Wastewater Treatment · Electromagnetic flow meter — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was volumetric flow of conductive liquids.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing liner and electrode pairing by conductivity, solids and abrasion.
What We Did
We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing liner and electrode pairing by conductivity, solids and abrasion, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — no obstruction, so pressure loss is minimal and upkeep low, with routine maintenance falling noticeably.
Food & Beverage · Electromagnetic flow meter — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Electromagnetic flow meter, focusing on volumetric flow of conductive liquids.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Electromagnetic flow meter specification must therefore cover choosing liner and electrode pairing by conductivity, solids and abrasion.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing liner and electrode pairing by conductivity, solids and abrasion, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — no obstruction, so pressure loss is minimal and upkeep low, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · Electromagnetic flow meter — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Electromagnetic flow meter; the focus is volumetric flow of conductive liquids.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing liner and electrode pairing by conductivity, solids and abrasion.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing liner and electrode pairing by conductivity, solids and abrasion, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means no obstruction, so pressure loss is minimal and upkeep low, which cut the workload on the site maintenance team.
Power & Energy · Electromagnetic flow meter — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Electromagnetic flow meter and the core task is volumetric flow of conductive liquids.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Electromagnetic flow meter cannot be specified generically — it calls for choosing liner and electrode pairing by conductivity, solids and abrasion.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing liner and electrode pairing by conductivity, solids and abrasion, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is no obstruction, so pressure loss is minimal and upkeep low.
Related Products
Endress+HauserElectromagnetic flowmeter
Endress+HauserElectromagnetic flowmeter
Endress+HauserBattery-powered electromagnetic flowmeter
Endress+HauserMAGPHANT
Endress+HauserElectromagnetic flowmeter
Endress+HauserElectromagnetic flowmeter
SiemensElectromagnetic flow sensor
Endress+Hauser