Technical Data
ComparePoint Level / Liquids
| Measuring Principle | Conductive |
| Characteristic / Application | One rod probe for high temperature and high pressure. corrosion resistant |
| Supply / Communication | Relay |
| Ambient temperature | -40 °C ... 80 °C (-40 °F ... 176 °F) |
| Process temperature | -40 °C ... 135 °C (-40 °F ... 275 °F) |
| Process pressure / max. overpressure limit | Vacuum ... 50 bar (Vacuum ... 725 psi) |
| Min. conductivity of medium | 20 µS/cm |
| Main wetted parts | PTFE, 316TI |
| Process connection | G1/2 |
| Sensor length | 0.05m ... 2m (2" ... 79") |
| Communication | Relay |
| Certificates / Approvals | ATEX |
| Components | Transmitter: FTW325 |
| Application limits | observe min. medium conductivity |
The economical 11375Z probe can be used for limit detection of various liquids in processes and tanks.
Advantages
A cooler can be fitted when measuring high-temperature liquids (e.g. 100°C)
Probe length can be shortened
WHG (German Water Resources Act) + ATEX II 1/2 G approval
Can be connected to the independent FTW325 switching unit
Linear monitoring, safe and reliable
No moving parts in the tank, no wear, long service life, reliable function
Economical probe for conductive liquids
Areas of application
For limit detection of various liquids in processes or tanks:
Conductivity of 0.02mS/cm
Temperature range 40~+200°C
Pressure up to 50bar; linear monitoring and overflow protection in explosion Zone 0, upper/lower limit detection in tanks, protection of pipeline pumps, and two-point control
E+H Product Configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products to compare in the boxes below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Conductive Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Conductive.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Conductive Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Conductive.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Conductive Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Conductive.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Conductive Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Conductive.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserLiquipoint T FTW31
Endress+HauserNivotester FTW325
Endress+HauserLiquipoint FTW23
Endress+HauserLiquipoint FTW33
Endress+HauserOne rod probe 11371
Endress+HauserLiquipoint T FTW32
Endress+HauserPump protection sensor FTW360