Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

11375Z One rod probe

11375Z One rod probe
One rod probe 11375Z
The 11375Z is a cost-effective and reliable solution for conductive point level detection in process or storage tanks for all kinds of liquids.
Compare

Point Level / Liquids

Measuring Principle Conductive
Characteristic / Application One rod probe for high temperature and high pressure. corrosion resistant
Supply / Communication Relay
Ambient temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature -40 °C ... 135 °C
(-40 °F ... 275 °F)
Process pressure / max. overpressure limit Vacuum ... 50 bar
(Vacuum ... 725 psi)
Min. conductivity of medium 20 µS/cm
Main wetted parts PTFE, 316TI
Process connection G1/2
Sensor length 0.05m ... 2m
(2" ... 79")
Communication Relay
Certificates / Approvals ATEX
Components Transmitter: FTW325
Application limits observe min. medium conductivity

The economical 11375Z probe can be used for limit detection of various liquids in processes and tanks.

 

Advantages

A cooler can be fitted when measuring high-temperature liquids (e.g. 100°C)

Probe length can be shortened

WHG (German Water Resources Act) + ATEX II 1/2 G approval

Can be connected to the independent FTW325 switching unit

Linear monitoring, safe and reliable

No moving parts in the tank, no wear, long service life, reliable function

Economical probe for conductive liquids

 

Areas of application

For limit detection of various liquids in processes or tanks:

 

Conductivity of 0.02mS/cm

Temperature range 40~+200°C

Pressure up to 50bar; linear monitoring and overflow protection in explosion Zone 0, upper/lower limit detection in tanks, protection of pipeline pumps, and two-point control

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

All documents for this model
1 documents · click to expand
TI

Rod Probe 11375Z Technical Information English

Rev. 0510 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductive — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on conductive and the core task is conductive point-level and leakage detection.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So conductive cannot be specified generically — it calls for choosing electrode material and insulation by conductivity and temperature.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing electrode material and insulation by conductivity and temperature, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is no moving parts, giving fast pump and valve interlock response.

Food & Beverage

Food & Beverage · conductive — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted conductive properly configured on the existing plant, with the aim of conductive point-level and leakage detection.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the conductive configuration has to involve choosing electrode material and insulation by conductivity and temperature.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing electrode material and insulation by conductivity and temperature, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is no moving parts, giving fast pump and valve interlock response, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductive — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was conductive point-level and leakage detection.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing electrode material and insulation by conductivity and temperature.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing electrode material and insulation by conductivity and temperature, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — no moving parts, giving fast pump and valve interlock response, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · conductive — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from conductive, focusing on conductive point-level and leakage detection.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The conductive specification must therefore cover choosing electrode material and insulation by conductivity and temperature.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing electrode material and insulation by conductivity and temperature, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — no moving parts, giving fast pump and valve interlock response, with confidence in this measuring point improving markedly.