Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

11371 One rod probe

11371 One rod probe
One rod probe 11371
Configurable Models 1 models
The 11371 is used as point level detection in vessels with liquid foodstuffs, e.g. milk, beer, fruit juice. Corrosion-resistant materials for rod and insulation and the capability of CIP/SIP make it perfectly fit for the food industry.
Compare

Point Level / Liquids

Measuring Principle Conductive
Characteristic / Application One rod probe. Simple rod shortening or rod change on location
Supply / Communication Relay
Ambient temperature -20 °C ... 120 °C
(-4 °F ... 248 °F)
Process temperature -10 °C ... 100 °C
(+10 °F ... +210 °F)
Process pressure / max. overpressure limit Vacuum ... 10 bar
(Vacuum ... 145 psi)
Min. conductivity of medium 20 µS/cm
Main wetted parts PFA, 316TI
Process connection G 1 1/2A
set-in nozzle
Sensor length 0.05 m ... 2 m
(2" ... 79")
Communication Relay
Components Transmitter: FTW325
Application limits Observe min. medium conductivity

The 11371 probe is used for limit detection of food-grade liquids such as milk, beer, fruit juice, etc. The probe is made of corrosion-resistant insulating material and has CIP/SIP functionality, making it highly suitable for the food industry.

 

Advantages

Rod probe made of corrosion-resistant insulating material (can also be used for measuring corrosive media)

Suitable for CIP cleaning and steam sterilization (no special cleaning steps required)

Various process connection forms selectable (optimized application compatibility)

Probe can be shortened as required (beneficial for inventory management)

 

Areas of application

For limit detection in tanks of food-grade liquids such as milk, beer, fruit juice, etc. The probe consists of the following parts:

 

Partially insulated sintered PFA stainless steel rod

Stainless steel weld-in or threaded connection

Gasket specially designed for food

Stainless steel housing

Cable gland M16, etc.

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

 

 

Accessories/Spare parts

 

 

Source:Endress+Hauserwebsite public information

1 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductive — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on conductive and the core task is conductive point-level and leakage detection.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So conductive cannot be specified generically — it calls for choosing electrode material and insulation by conductivity and temperature.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing electrode material and insulation by conductivity and temperature, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is no moving parts, giving fast pump and valve interlock response.

Food & Beverage

Food & Beverage · conductive — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted conductive properly configured on the existing plant, with the aim of conductive point-level and leakage detection.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the conductive configuration has to involve choosing electrode material and insulation by conductivity and temperature.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing electrode material and insulation by conductivity and temperature, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is no moving parts, giving fast pump and valve interlock response, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductive — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was conductive point-level and leakage detection.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing electrode material and insulation by conductivity and temperature.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing electrode material and insulation by conductivity and temperature, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — no moving parts, giving fast pump and valve interlock response, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · conductive — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from conductive, focusing on conductive point-level and leakage detection.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The conductive specification must therefore cover choosing electrode material and insulation by conductivity and temperature.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing electrode material and insulation by conductivity and temperature, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — no moving parts, giving fast pump and valve interlock response, with confidence in this measuring point improving markedly.