Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FTW31 Liquipoint T

FTW31 Liquipoint T
Liquipoint T FTW31
Configurable Models 5 models
The Liquipoint FTW31 offers simple and safe point level detection in conductive liquids. It offers numerous measuring possibilities due to multipoint detection (up to 5 rods).
Compare

Point Level / Liquids

Measuring Principle Conductive
Characteristic / Application Compact rod probe with multipoint detection, possible up to 5 switch points. Simple rod shortening.
Supply / Communication DC PNP 10,8V ... 45V
Relay 20V ... 230V AC
Relay 20V ... 55V DC
Ambient temperature -40 °C ... 70 °C
(-40 °F ... 158 °F)
Process temperature -40 °C ... 100 °C
(-40 °F ... 212 °F)
Process pressure / max. overpressure limit Vacuum ... 10 bar
(Vacuum ... 145 psi)
Min. conductivity of medium 10 µS/cm
Main wetted parts 316L, PP, PPS
Max. tensile strength 1000 N
Process connection G 1 1/2
NPT1 1/2"
Sensor length 0.1m ... 4m
(3.9" ... 157")
Communication DC PNP
Relay
Certificates / Approvals ATEX, EAC Ex
Safety approvals Leakage Detection
Components Transmitter: FTW325
Application limits Observe min. medium conductivity

Product Overview

The FTW31 is a rod-type conductive point level switch; for the cable version use the FTW32.

  • The Liquipoint FTW31 can be used for point level detection of conductive liquids, with simple and safe measurement. The multi-point detection function (up to 5 probes) gives the Liquipoint FTW31 a wider measuring range.

  • Benefits

  • One probe can be used for up to five point level detections

  • Two-point control with upper and lower limit detection

  • Flexible use:

  • 1. Rod probe with plug-in electronics, optionally with 2 or 3 transistor or relay outputs;

  • 2. Connection to a separate transmitter power supply unit

  • No calibration required; suitable for common conductive liquid measurement

  • No moving parts: - long service life - no wear and blockage, reliable operation

  • Four selectable measuring ranges: 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ

  • Economical probe for conductive liquids

  • Application areas

  • The Liquipoint T sensor is suitable for point level detection of conductive liquids (10 μS/cm). Depending on the number of measuring points (up to 5 rod probes), tasks such as overflow protection, dry-run protection, two-point pump control and multi-point detection can be performed via the existing process connections.

Spare Parts & Accessories 10

10 spare parts · click to collapse
Order codeDescription
52017268plastic coverfor version without electronicsDetails
52025606plastic coverGasket EPDM Polyester housingDetails
52004137O-ringCover seal set Polyester housing F16Details
52017271electronic plug-in modulefor limit switch, conductive. Liquipoint T output PNP 10.8-45VDC.Details
52017273electronic plug-in modulefor limit switch, conductive. Liquipoint T output NAMURDetails
52026734Monitoring boardLiquipoint T.Details
52017270IsolatorProvide spacer FTW31-rods, 4 piecesDetails
71127760SunshadeUsage: FDR56, FMI21, FMI51/FMI52, FQR56, FTI51/FTI52/FTI55/FTI56, FTI77, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/FTL85, FTM20/FTM21, FTM50/FTM51/FTM52, FTR20, FTW31/FTW32/FTW33.Details
52014047O-ringProcess gasket for process connections G1-1/2Details
52014146mounting nut六角形,SW60 适合FTW31,FTW32,FMI21Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source: public information from the Endress+Hauser website

5 models · click to collapse
All documents for this model
6 documents · click to expand
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

技术资料 Liquipoint T FTW31, FTW32 Chinese

Rev. 1313 20 pages
Preview
TI

技术资料 Liquipoint T FTW31, FTW32 Chinese

Rev. 0610 28 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

Liquipoint T FTW31, FTW32 Technical Information English

Rev. 1416 24 pages
Preview
TI

Liquipoint T FTW31, FTW32 Technical Information English

Rev. 0610 28 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductive — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on conductive and the core task is conductive point-level and leakage detection.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So conductive cannot be specified generically — it calls for choosing electrode material and insulation by conductivity and temperature.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing electrode material and insulation by conductivity and temperature, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is no moving parts, giving fast pump and valve interlock response.

Food & Beverage

Food & Beverage · conductive — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted conductive properly configured on the existing plant, with the aim of conductive point-level and leakage detection.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the conductive configuration has to involve choosing electrode material and insulation by conductivity and temperature.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing electrode material and insulation by conductivity and temperature, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is no moving parts, giving fast pump and valve interlock response, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductive — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was conductive point-level and leakage detection.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing electrode material and insulation by conductivity and temperature.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing electrode material and insulation by conductivity and temperature, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — no moving parts, giving fast pump and valve interlock response, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · conductive — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from conductive, focusing on conductive point-level and leakage detection.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The conductive specification must therefore cover choosing electrode material and insulation by conductivity and temperature.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing electrode material and insulation by conductivity and temperature, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — no moving parts, giving fast pump and valve interlock response, with confidence in this measuring point improving markedly.