Technical Data
ComparePoint Level / Liquids
| Measuring Principle | Conductive |
| Characteristic / Application | Compact rod probe with multipoint detection, possible up to 5 switch points. Simple rod shortening. |
| Supply / Communication | DC PNP 10,8V ... 45V Relay 20V ... 230V AC Relay 20V ... 55V DC |
| Ambient temperature | -40 °C ... 70 °C (-40 °F ... 158 °F) |
| Process temperature | -40 °C ... 100 °C (-40 °F ... 212 °F) |
| Process pressure / max. overpressure limit | Vacuum ... 10 bar (Vacuum ... 145 psi) |
| Min. conductivity of medium | 10 µS/cm |
| Main wetted parts | 316L, PP, PPS |
| Max. tensile strength | 1000 N |
| Process connection | G 1 1/2 NPT1 1/2" |
| Sensor length | 0.1m ... 4m (3.9" ... 157") |
| Communication | DC PNP Relay |
| Certificates / Approvals | ATEX, EAC Ex |
| Safety approvals | Leakage Detection |
| Components | Transmitter: FTW325 |
| Application limits | Observe min. medium conductivity |
Product Overview
The FTW31 is a rod-type conductive point level switch; for the cable version use the FTW32.
-
The Liquipoint FTW31 can be used for point level detection of conductive liquids, with simple and safe measurement. The multi-point detection function (up to 5 probes) gives the Liquipoint FTW31 a wider measuring range.
-
Benefits
-
One probe can be used for up to five point level detections
-
Two-point control with upper and lower limit detection
-
Flexible use:
-
1. Rod probe with plug-in electronics, optionally with 2 or 3 transistor or relay outputs;
-
2. Connection to a separate transmitter power supply unit
-
No calibration required; suitable for common conductive liquid measurement
-
No moving parts: - long service life - no wear and blockage, reliable operation
-
Four selectable measuring ranges: 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
-
Economical probe for conductive liquids
-
Application areas
-
The Liquipoint T sensor is suitable for point level detection of conductive liquids (10 μS/cm). Depending on the number of measuring points (up to 5 rod probes), tasks such as overflow protection, dry-run protection, two-point pump control and multi-point detection can be performed via the existing process connections.
Spare Parts & Accessories 10
10 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 52017268 | plastic coverfor version without electronics | Details |
| 52025606 | plastic coverGasket EPDM Polyester housing | Details |
| 52004137 | O-ringCover seal set Polyester housing F16 | Details |
| 52017271 | electronic plug-in modulefor limit switch, conductive. Liquipoint T output PNP 10.8-45VDC. | Details |
| 52017273 | electronic plug-in modulefor limit switch, conductive. Liquipoint T output NAMUR | Details |
| 52026734 | Monitoring boardLiquipoint T. | Details |
| 52017270 | IsolatorProvide spacer FTW31-rods, 4 pieces | Details |
| 71127760 | SunshadeUsage: FDR56, FMI21, FMI51/FMI52, FQR56, FTI51/FTI52/FTI55/FTI56, FTI77, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/FTL85, FTM20/FTM21, FTM50/FTM51/FTM52, FTR20, FTW31/FTW32/FTW33. | Details |
| 52014047 | O-ringProcess gasket for process connections G1-1/2 | Details |
| 52014146 | mounting nut六角形,SW60 适合FTW31,FTW32,FMI21 | Details |
Configurator / Comparison
Source: public information from the Endress+Hauser website
Manuals & Documents 6
All documents for this model6 documents · click to expand
TI 焊接接头、过程转接头和法兰 Chinese
技术资料 Liquipoint T FTW31, FTW32 Chinese
技术资料 Liquipoint T FTW31, FTW32 Chinese
TI Weld-in adapter, process adapter and flanges English
Liquipoint T FTW31, FTW32 Technical Information English
Liquipoint T FTW31, FTW32 Technical Information English
Case Studies
Municipal Wastewater Treatment · conductive — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on conductive and the core task is conductive point-level and leakage detection.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So conductive cannot be specified generically — it calls for choosing electrode material and insulation by conductivity and temperature.
Solution
The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing electrode material and insulation by conductivity and temperature, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is no moving parts, giving fast pump and valve interlock response.
Food & Beverage · conductive — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted conductive properly configured on the existing plant, with the aim of conductive point-level and leakage detection.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the conductive configuration has to involve choosing electrode material and insulation by conductivity and temperature.
Configuration
Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing electrode material and insulation by conductivity and temperature, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is no moving parts, giving fast pump and valve interlock response, and the readings are now used for process tuning.
Chemical & Pharmaceutical · conductive — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was conductive point-level and leakage detection.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing electrode material and insulation by conductivity and temperature.
What We Did
We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing electrode material and insulation by conductivity and temperature, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — no moving parts, giving fast pump and valve interlock response, with routine maintenance falling noticeably.
Power & Energy · conductive — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from conductive, focusing on conductive point-level and leakage detection.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The conductive specification must therefore cover choosing electrode material and insulation by conductivity and temperature.
Delivery Approach
Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing electrode material and insulation by conductivity and temperature, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — no moving parts, giving fast pump and valve interlock response, with confidence in this measuring point improving markedly.