The Liquipoint FTW23 is developed and built for the food industry and meets all international hygiene requirements. The device also fits perfectly for industrial applications in all industries. It is intended for use in applications in liquid media without build-up. The IO-Link capability allows easy parameter setting.
Compare

Point Level / Liquids

Measuring Principle Capacitive Liquid
Characteristic / Application Compact point level switch for using in water based liquids
Specialities CIP and SIP suitable
Supply / Communication 10…30 V DC
Ambient temperature -20...70°C
-4... 158°F
Process temperature Standard:
-20 ... 100°C
Cleaning:
-20 ... 135°C for 1h
-4 ... 275F for 1h
Process pressure / max. overpressure limit Vacuum ... 16 bar
Vacuum ....232 psi
Main wetted parts Sensor: 316L
Sensor isolation: PEEK
Process connection Thread G1, G1/2, G3/4, M24
Communication DC PNP
IO- Link
Certificates / Approvals CSA C/US
Design approvals EN 10204-3.1
Hygienic approvals 3A, EHEDG
Options Weld-in adapter,
Process adapter for hygienic process connections
Application limits Conductive foam is recognizes as a liquid

Product Overview

  • Liquipoint FTW23 meets all international hygienic requirements, is designed and manufactured for the food industry and is also suitable for industrial applications in all industries. Specially designed for applications with non-adhesive liquid media. The IO-Link function simplifies parameter setting. Efficient:

  • economical to use

  • function check via test magnet

  • Simple:

  • no calibration or adjustment required

  • no special tools required, plug-and-play

  • IO-Link connection function

  • Benefits

  • Compact design for easy installation, even in confined spaces or hard-to-reach locations

  • Easy device configuration with engineering tools; IO-Link reduces costs and complexity

  • Resistant to CIP and SIP cleaning - highest degree of protection IP69

  • No need for individual adjustment for each medium

  • On-site function check via LED display

  • Application

  • Suitable for use in storage tanks, mixing vessels and pipes. Designed for water-based media; the dielectric constant of the medium is normally required to be >20, but calibration via IO-LINK allows detection of media with a dielectric constant >1.5.

  • Process connection: thread

  • Temperature: -20...+100°C (-4...+212°F); CIP/SIP: max. 135°C (275°F) within 1 h

  • Pressure: -1...16 bar abs (-14.5...232 psi)

  • Hygienic approval

Spare Parts & Accessories 58

58 spare parts · click to collapse
Order codeDescription
52006263Process connection | Socket for plug 4p-125V, 4A-M12M12 插头 自连接 M12转成格兰Details
52024216Cable socketM12x1 plug 5m cable PVC, 316L lock Especially for sanitary applicationsDetails
52018763Cable with connector | Cable 4x0.34, box M12, 316L, LED, 9适用于M12插头,集成LED指示 带5m电缆 PVC 材质 316L锁紧螺母 针对卫生型应用Details
52010285M12 connector, 90° angled, with 5 m cable适用于M12插头 带5m电缆 PVC材质,铜镀锡/ 镍锁紧螺母Details
52010156socket wrenchLiquiphant T FTL20/FTL20HDetails
71267011Test magnetUsage: FTL20/FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51H, FTW23, FTW33.Details
71194296O-ringProcess gasket DIN7603-A. Usage: process connection, FMI51, FTI51, FTL31/FTL33, FTW23/FTW33.Details
71185027O-ringProcess gasket DIN7603-A. Usage: process connection, FMI51, FMI52, FTI51, FTI52, FMP50, FMP51, FMP56, FMR43, FMR60B, FMR62, QMW43, FTL31, FTL33, FTL41, FTW23, FTW33, FTL50, FTL50H, FTL51, FTL51B, FTL80, FTL81.Details
52014048O-ringProcess gasket for process connections G1Details
71258357Process connection|Weld-in G3/4, d=29, 316LFlush mount process connection. For pipe-mounting. Material: 316L. Seal: silicone O-ring. FDA, 3-A compliant. additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FTL20/FTL20H, FTL31/FTL33, FTW23, FTW33, QMW43.Details
52028295weld socketFlush mount process connection FTL20 "1", FTL20H "GDJ" w/o flange Material: 316L, EHEDG compliant Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts)Details
71258355Stainless steel connector | Weld-in adapter G3/4 d=50, 316LFlush mount process connection. For vessel-mounting. Material: 316L. Seal: silicone O-ring. FDA, 3-A compliant. additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FTL20/FTL20H, FTL31/FTL33, FTW23, FTW33, FMI51, FTI51, QMW43, 11371. Usage: TMR35.Details
52018765weld socketFlush mount process connection FTL20 "1", FTL20H "GDJ", FMI51, FTI51 "GQJ" Material: 316L, EHEDG compliant Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts)Details
71675412welding boss blind plugBlind plug for closing weld-in adapter G3/4 71258357/52028295, 71258355/52018765. Material: AISI 316L (1.4435). Roughness (process side): Ra < 3.2 μm (126 μin). Silicone O-ring. Usage: FMI51, FTI51, FTL31, FTL33, FTW23, FTW33, 11371, TMR35, TM311, TM371, TM372, TM411, TT411.Details
71675415G3/4 brass weld boss blind plugWelding dummy for welding the weld-in adapter G3/4 71258357/52028295, 71258355/52018765. Material: Brass. Usage: FMI51, FTI51, FTL31, FTL33, FTW23, FTW33, TMR35, TM311, TM371, TM372, TM411, TT411.Details
71529759O-ringMaterial: EPDM Usage: weld-in adapter G3/4", d29, 316L (71258357 / 52028295), FTW23, FTW33, QMW43, 11371, FTL31, FTL33. weld-in adapter G3/4", d50, 316L (71258355 / 52018765) FMI51, FTI51 FTW23, FTW33, QMW43, 11371, FTL31, FTL33.Details
71675404O-Ring 15.08x2.62 FKM, 5 pcsO-ring set for weld-in adapter G3/4. Material: FKM. Usage: FMI51, FTI51, FTL31, FTL33, FTW23, FTW33, QMW43.Details
71675405O-ring 15,08x2,62 EPDM, 5 pcsO-ring set for weld-in adapter G3/4. Material: EPDM. Usage: FMI51, FTI51, FTL31, FTL33, FTW23, FTW33, QMW43.Details
71258358Weld socket G1, d=53, 316LFlush mount process connection. Material: 316L. Seal: silicone O-ring. FDA, 3-A compliant. Additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FMI51, FMI52, FTI51, FTI52, FTL31, FTL33, FTL41, FTL43, FTL50, FTL50H, FTL51, FTL51H, FTL51B, FTL63, FTL80, FTL81, FTL260, FTL330H, FTL330L, PTP35, PTP33B, PMP23, PMP43, PMP51, FTW23, FTW33, QMW43.Details
71093129weld socketFlush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material Seal: silicone O-ring FDA, 3-A compliant. Additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FMI51, FMI52, FTI51, FTI52, FTL31, FTL20H, FTL33, FTL41, FTL43, FTL50, FTL50H, FTL51, FTL51B, FTL51H, FTL63, FTL80, FTL81, FTL260, PMP135, PTP35, PTP33B, PMP23, PMP43, PMP51, FTW23, FTW33, QMW43.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

19 models · click to collapse
All documents for this model
8 documents · click to expand
BA

Liquipoint FTW23 操作手册 Chinese

Rev. 0215 24 pages
Preview
BA

Liquipoint FTW23 IO-Link 操作手册 Chinese

IO-Link Rev. 0117 40 pages
Preview
BA

Liquipoint FTW23 Operating Instructions Betriebsanleitung English

Rev. 0215 36 pages
Preview
BA

Liquipoint FTW23 IO-Link Operating Instructions English

IO-Link Rev. 0117 40 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

TI Liquipoint FTW23 Chinese

Rev. 0623 16 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

TI Liquipoint FTW23 English

Rev. 0623 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductive — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on conductive and the core task is conductive point-level and leakage detection.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So conductive cannot be specified generically — it calls for choosing electrode material and insulation by conductivity and temperature.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing electrode material and insulation by conductivity and temperature, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is no moving parts, giving fast pump and valve interlock response.

Food & Beverage

Food & Beverage · conductive — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted conductive properly configured on the existing plant, with the aim of conductive point-level and leakage detection.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the conductive configuration has to involve choosing electrode material and insulation by conductivity and temperature.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing electrode material and insulation by conductivity and temperature, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is no moving parts, giving fast pump and valve interlock response, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductive — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was conductive point-level and leakage detection.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing electrode material and insulation by conductivity and temperature.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing electrode material and insulation by conductivity and temperature, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — no moving parts, giving fast pump and valve interlock response, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · conductive — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from conductive, focusing on conductive point-level and leakage detection.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The conductive specification must therefore cover choosing electrode material and insulation by conductivity and temperature.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing electrode material and insulation by conductivity and temperature, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — no moving parts, giving fast pump and valve interlock response, with confidence in this measuring point improving markedly.