4W5B Total solids flowmeter 500

4W5B Total solids flowmeter 500
Total solids flowmeter 500
Inline meter as remote version for continous, real-time total solids measurement in wastewater sludge treatment. Saves energy, polymers, and disposal costs – from primary sludge to dewatered sludge.
Compare

Total Solids / Total Suspended Solids

Measuring Principle Total solids measurement via microwave transmission
Product headline Total solids measurement for the water and wastewater industry, remote version with up to 4 I/Os.
Ideal for total solids measurement, e.g. for sludge treatment in water/waste water treatment plants.
Sensor features Polished tube – less maintenance
due to reduced adhesion. Fewer process measuring points – multivariable measurement (total solids, temperature, conductivity). Easy installation – proven sensor construction.
Repeatability (0.02%). Short installation length. Measuring up to 50% total solids content.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os. Onboard load calculation – less effort needed in programming. Integrated verification – Heartbeat Technology.
Full access to process and diagnostic information – numerous, freely combinable I/Os. Onboard load calculation – less effort needed in programming. Integrated verification – Heartbeat Technology.
Nominal diameter range DN 50 to 300
Installation Inline installation
Material Measuring tube:
Stainless steel 1.4408 according to DIN EN 10213, CF3M according to ASME A351)
Temperature sensor:
1.4435 (316L)
Measuring range 0 to 500 g/l (0 to 31 lb/ft3), 0 to 50 %TS
Process pressure PN 16, Class 150, 10K
Connection Wafer
Ingress protection IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Output / communication 4-20mA HART, Modbus RS485
Power supply AC 100 to 230 V / DC 24 V
Product safety CE Marking, UKCA Marking
Hazardous area approvals ATEX, IECEx, CSA C/US
Material certificates 3.1 material
Metrological approvals and certificates Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Proline Teqwave MW 500 – total solids meter
Online measuring device for measuring total solids content in wastewater sludge, remote version with up to 4 I/Os
Advantages
Reliable, real-time measuring performance – permanent online measurement with excellent repeatability

Reduced maintenance – polished measuring tube reduces buildup and extends cleaning intervals

Reduced programming effort – can be combined with a flowmeter for onboard load rate calculation

Fewer process measuring points – multivariable measurement (total solids, temperature, conductivity)

Easy installation – innovative sensor structure and state-of-the-art technology with web server (optional WLAN)

Full access to process and diagnostic information – numerous freely combinable I/Os available

Integrated verification – Heartbeat Technology enables documented device function without interrupting the process
Field of application
The online measuring device Teqwave MW 500 enhances sludge treatment in wastewater treatment plants through real-time total solids measurement using microwave transmission. This enables faster and more efficient process optimization and reduces laboratory measurements. Continuous data availability improves solid-liquid separation, increases operational safety and enables rapid response to process changes. Typical sludge treatment applications include clarification, digestion and dewatering.

The remote transmitter version Proline 500 enables maximum installation flexibility in challenging environments. It is equipped with a built-in web server and optional integrated WLAN, simplifying operation and providing additional process and device information.

Spare Parts & Accessories 28

28 spare parts · click to collapse
Order codeDescription
XPD0095-300/500 ISEM electronic plug-in moduleUsage: Valid for approvals acc. feature 010. Consists of: ISEM (sensor electronic module) V314-00.Enquire
XPD0037-I/O moduleUsage: Proline 300/500Enquire
XPD0038-I/O moduleUsage: Proline 300/500Enquire
XPD0031-Display moduleUsage: Proline 300/500, DKX001.Enquire
71323009Power supply assemblyUsage: Promag/Promass/Prosonic Flow/ t-mass/Teqwave MW 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment.Details
71323013Main electronics connection board assembly, non-explosion-proof, 500 digitalUsage: Promag/Promass/Prosonic Flow/ t-mass/Teqwave MW 500 digital, transmitter housing, electronic compartment.Details
71323015ISEM Connection Board Assembly, Explosion-proof, 500 DigitalUsage: Promag/Promass/t-mass/ Teqwave MW 500 digital, sensor connection housing.Details
71185788T-DAT moduleDetails
71323006ribbon cable assemblyUsage: Promag/Promass/t-mass/ Teqwave MW 500 digital, sensor connection housing.Details
71323077Terminal Block AssemblyUsage: transmitter housing Alu/polycarbonate, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus, Profinet APL, Modbus TCP APL. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.Details
71327820Terminal Block AssemblyUsage: transmitter housing Alu/polycarbonate, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.Details
71384170Promag400/500 coverUsage: Prosonic Flow 400, Promag 400(C), (C) = generation index C, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,40x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.Details
71408508housing coverUsage: Promag/Prosonic Flow 400, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 800(C), (C) = generation index C, transmitter housing polycarbonate. Consists of: cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.Details
71278078cover seal ringUsage: Prosonic Flow 400, Promag 400(C), (C) = generation index C, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, transmitter housing Alu. Consists of: 10x O-Ring 196,40x3,53 VMQ, default and -50oC/-58oF.Details
71278077Polycarbonate cover gasketUsage: Prosonic Flow 400, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 400/800(C), (C) = generation index C, transmitter housing polycarbonate. Consists of: 10x O-Ring 196,44x3,53 VMQ.Details
71228796Cover assemblyUsage: Promag 10/500, Promass 500, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.Details
71323051Housing seal kitUsage: Promass 500, Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital. Sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket HNBR for housing/sensor.Details
71276494Clamp fastening, screwsUsage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass, Promag/Promass 500, Promag 10, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover clamp, screw M4x16.Details
71450719Adapter M12, RJ45, L= 80 mm (for t-mass F 300/50)Usage: Proline 300/500.Details
71228792Display protection coverUsage: Prosonic Flow 400, Promag 400(C), (C) = generation index C, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, transmitter housing Alu. Consists of: display protection 1.4301, installation material.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
teqwave mw500 total solids meter(65 条)→

数据摘自 Endress+Hauser 操作手册,含状态信号、可能原因与维修指导。

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Ultrasonic flowmeter — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Ultrasonic flowmeter properly configured on the existing plant, with the aim of transit-time ultrasonic measurement of liquid or gas flow.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Ultrasonic flowmeter configuration has to involve checking straight runs, pipe internal condition and entrained gas.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant checking straight runs, pipe internal condition and entrained gas, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clamp-on versions avoid pipe work, minimising shutdown in revamps, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Ultrasonic flowmeter — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was transit-time ultrasonic measurement of liquid or gas flow.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking straight runs, pipe internal condition and entrained gas.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around checking straight runs, pipe internal condition and entrained gas, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clamp-on versions avoid pipe work, minimising shutdown in revamps, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Ultrasonic flowmeter — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Ultrasonic flowmeter, focusing on transit-time ultrasonic measurement of liquid or gas flow.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Ultrasonic flowmeter specification must therefore cover checking straight runs, pipe internal condition and entrained gas.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on checking straight runs, pipe internal condition and entrained gas, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clamp-on versions avoid pipe work, minimising shutdown in revamps, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Ultrasonic flowmeter — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Ultrasonic flowmeter; the focus is transit-time ultrasonic measurement of liquid or gas flow.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking straight runs, pipe internal condition and entrained gas.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on checking straight runs, pipe internal condition and entrained gas, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clamp-on versions avoid pipe work, minimising shutdown in revamps, which cut the workload on the site maintenance team.