Technical Data
CompareConcentration
| Measuring Principle | Ultrasonic concentration |
| Product headline | Smart, flexible inline measuring device – individually for your process. Easy and efficient – real-time in situ liquid analysis. Continuous concentration measurement of liquids in pipes. |
| Sensor features | Full transparency – constant monitoring of product quality without sampling. Highest process safety – reliable metering due to robust, maintenance-free sensor. Cost-saving – fewer measuring points due to multivariable measurement. Nominal diameter: DN 8 to 25 (³⁄₈ to 1"). Full-bore design without pressure loss. |
| Transmitter features | Customized usage – innovative application concept, expendable for changing measuring tasks. Simplified process control – user-friendly operation and clear status visualization. Local data backup – integrated data storage for measured values up to 7,5 years. Industry-compliant, easy installation via DIN rail. 3.5" TFT color touch screen or LED indication. 4-20 mA, Modbus TCP. |
| Nominal diameter range | DN 8 (1/4“) to DN 25 (1“) |
| Measured variables | Concentration, sound velocity, temperature, acoustic density, dispersion |
| Max. measurement error | Acoustic density: ±0.01g/cm³ Temperature: ±0.5K Sound velocity: +-2m/s |
| Measuring range | Concentration According to concentration app data sheet, maximum 0 to 100 % Sound velocity 600 to 2000 m/s Temperature maximum 0 to +100 °C (32 to +212 °F) Acoustic Density 0.7 to 1.5 g/cm³ |
| Design | Inline |
| Material | Sensor material: Stainless steel V4A 1.4571 (316Ti) Transmitter housing material: Aluminum anodized and glas |
| Process temperature | 0 to 100 °C (32 to 212 °F) |
| Process pressure | max. 16 bar at 20 °C (232 psi at 68 °F) |
| Ex certification | Non-hazardous area |
| Ingress protection | Sensor: IP68 (with plugged-in cable) Transmitter: IP40 |
| Display/Operation | LED status indication TFT color touch display |
| Outputs | Modbus TCP, Relay (AC 50V, DC30V 1A), 4-20mA/0 to 10V Analog output |
| Power supply | DC 24V +-20% |
| Product safety | CE, UKCA, RCM |
Density/Concentration
| Measuring Principle | Ultrasonic concentration |
| Product headline | Smart, flexible inline measuring device – individually for your process. Easy and efficient – real-time in situ liquid analysis. Continuous concentration measurement of liquids in pipes. |
| Sensor features | Full transparency – constant monitoring of product quality without sampling. Highest process safety – reliable metering due to robust, maintenance-free sensor. Cost-saving – fewer measuring points due to multivariable measurement. Nominal diameter: DN 8 to 25 (³⁄₈ to 1"). Full-bore design without pressure loss. |
| Transmitter features | Customized usage – innovative application concept, expendable for changing measuring tasks. Simplified process control – user-friendly operation and clear status visualization. Local data backup – integrated data storage for measured values up to 7,5 years. Industry-compliant, easy installation via DIN rail. 3.5" TFT color touch screen or LED indication. 4-20 mA, Modbus TCP. |
| Nominal diameter range | DN 8 (1/4“) to DN 25 (1“) |
| Wetted materials | Stainless steel 1.4571 (316 Ti) |
| Measured variables | Concentration, sound velocity, temperature, acoustic density, dispersion |
| Max. measurement error | Acoustic density: ±0.01g/cm³ Temperature: ±0.5K Sound velocity: +-2m/s |
| Measuring range | Concentration According to concentration app data sheet, maximum 0 to 100 % Sound velocity 600 to 2000 m/s Temperature maximum 0 to +100 °C (32 to +212 °F) Acoustic Density 0.7 to 1.5 g/cm³ |
| Max. process pressure | max. 16 bar at 20 °C (232 psi at 68 °F) |
| Medium temperature range | 0 to 100 °C (32 to 212 °F) |
| Ambient temperature range | 0 to 50°C (32 to 122°F) |
| Sensor housing material | Stainless steel V4A 1.4571 (316 Ti) |
| Transmitter housing material | Anodized aluminium, Glas |
| Degree of protection | Sensor: IP68 (with plugged-in cable) Transmitter: IP40 |
| Display/Operation | LED status indication TFT color touch display |
| Outputs | Modbus TCP, Relay (AC 50V, DC30V 1A), 4-20mA/0 to 10V Analog output |
| Inputs | 2 digital inputs for configuring the display and output during operation. |
| Power supply | DC 24V +-20% |
| Hazardous area approvals | Non-hazardous area |
| Product safety | CE, UKCA, RCM |
The Teqwave F is the ideal choice for real-time liquid analysis in pipes, especially for skid-mounted equipment. The inline device performs high-precision online concentration measurement and is popular with equipment manufacturers and end users. The Teqwave can monitor up to four measured values simultaneously, reducing operating costs. The Teqwave transmitter can be optimized for your production requirements: the app allows you to conveniently set and extend your scope of application.
Benefits
Simple and efficient: real-time online liquid analysis
Fully transparent: continuous product quality monitoring without sampling
Maximum process safety: robust, maintenance-free sensor with reliable measurement
Economical: multivariable measurement requires fewer measuring points
Customized on demand: innovative app concept, simple retrofitting and upgrading, easy handling of all kinds of measuring tasks
Simplified process control: user-friendly operation with clear status display
On-site data backup: integrated measured value data storage with a storage period of up to 7.5 years
Applications
The waveguide acoustic monitoring technology measures precisely and reliably, safely detecting even the smallest changes
Can continuously measure the concentration of liquids in pipes
Device features
High measurement accuracy, resistant to high pressure
Nominal diameter: DN 8...25 (3/8...1")
Industry-standard, convenient mounting on a DIN rail
3.5" TFT color display or LED indicator
4...20 mA, Modbus TCP
Spare Parts & Accessories 4
4 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| XPD0047- | Cable-separated version, TeqwaveConnection cable between Sensor and Transmitter. | Enquire |
| DK9BXX- | Teqwave transmitter, DK9BXX | Enquire |
| DK9500- | Teqwave Concentration Apps | Enquire |
| D9FB- | Teqwave F, D9FB, inlineUltrasonic concentration meter Inline version. Application: Continuous concentration measurement of liquids in pipes. Full-bore design without pressure loss. Innovative application concept. :: Inline measuring device – smart, flexible and individual. :: Easy and efficient – real-time in situ liquid analysis. | Enquire |
Configurator / Comparison
Source: Endress+Hauserpublic information from the website
Measuring principle video
Click to playCase Studies
Municipal Wastewater Treatment · Ultrasonic flowmeter — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Ultrasonic flowmeter properly configured on the existing plant, with the aim of transit-time ultrasonic measurement of liquid or gas flow.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Ultrasonic flowmeter configuration has to involve checking straight runs, pipe internal condition and entrained gas.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant checking straight runs, pipe internal condition and entrained gas, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is clamp-on versions avoid pipe work, minimising shutdown in revamps, and the readings are now used for process tuning.
Food & Beverage · Ultrasonic flowmeter — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was transit-time ultrasonic measurement of liquid or gas flow.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking straight runs, pipe internal condition and entrained gas.
What We Did
We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around checking straight runs, pipe internal condition and entrained gas, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — clamp-on versions avoid pipe work, minimising shutdown in revamps, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Ultrasonic flowmeter — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Ultrasonic flowmeter, focusing on transit-time ultrasonic measurement of liquid or gas flow.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Ultrasonic flowmeter specification must therefore cover checking straight runs, pipe internal condition and entrained gas.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on checking straight runs, pipe internal condition and entrained gas, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — clamp-on versions avoid pipe work, minimising shutdown in revamps, with confidence in this measuring point improving markedly.
Power & Energy · Ultrasonic flowmeter — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Ultrasonic flowmeter; the focus is transit-time ultrasonic measurement of liquid or gas flow.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking straight runs, pipe internal condition and entrained gas.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on checking straight runs, pipe internal condition and entrained gas, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means clamp-on versions avoid pipe work, minimising shutdown in revamps, which cut the workload on the site maintenance team.
Related Products
Endress+HauserProsonic Flow 93T portable
Endress+HauserProsonic Flow 91WA1 Clamp On 1Ch/1Set
Endress+HauserUltrasonic flowmeter 93W
Endress+HauserUltrasonic flowmeter 9B2B
Endress+HauserUltrasonic concentration meter D9IB
Endress+HauserUltrasonic flowmeter
Endress+HauserUltrasonic flowmeter 93P
Endress+Hauser