Technical Data
CompareGas
| Measuring Principle | Ultrasonic flow |
| Product headline | The device for accurate, reliable biogas measurement with loop-powered technology. Inline flowmeter designed for measurement of wet biogas and digester gas under fluctuating process conditions. |
| Sensor features | Optimized for low pressure gas – specialized sensor design. No additional pressure loss – full-bore design. Process transparency – diagnostic capability. Multivariable device: flow, temperature and methane. Medium temperature: 0 to 80 °C (32 to 176 °F). Process pressure: 0.7 to 11 bar a (10.2 to 159 psi a). |
| Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals. |
| Nominal diameter range | Single‐path version: DN 50 (2"), DN 80 (3") Two‐path version: DN 100 to 200 (4 to 8") |
| Wetted materials | Sensor: 1.4404/1.4435 (316L) Transducer: HNBR Temperature sensor (option): AFM 34 |
| Measured variables | Volume flow, corrected volume flow, corrected methane volume flow, energy flow, methane fraction, calorific value, temperature |
| Max. measurement error | Volume flow (standard): ‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s) ‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s) Volume flow (option): ‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s) ‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s) |
| Measuring range | Standard: 1 to 30 m/s (3.28 to 98.4 ft/s) Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s) |
| Max. process pressure | 11 bar a (159 psi a) |
| Medium temperature range | 0 to +80 °C (+32 to +176 °F) |
| Ambient temperature range | Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) |
| Transmitter housing material | AlSi10Mg, coated; 1.4404 (316L) |
| Degree of protection | IP66/67, type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive) |
| Inputs | Current input 4‐20 mA (passive) |
| Digital communication | HART |
| Power supply | DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch Output) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, JPN, EAC, KC |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) |
| Pressure approvals and certificates | PED |
| Material certificates | 3.1 material (wetted parts) |
The Prosonic Flow B 200 enables precise and reliable measurement of wet biogas and digester gas under fluctuating process conditions. In addition, the Prosonic Flow B 200 provides real-time methane content analysis. This unique feature allows users not only to measure the gas flow continuously, but also to monitor the gas quality continuously. Furthermore, Heartbeat Technology ensures effective process control and energy balancing, and always guarantees compliance and process safety.
Advantages
Integrated real-time methane content measurement
The optimum measuring device for low-pressure gas - specially designed sensor
No pressure loss - full-bore design
High process transparency - with diagnostic functions
Convenient device wiring - separate connection compartment
Safe operation - no need to open the cover, as the display has touch control and backlighting
Comprehensive verification - Heartbeat technology
Application areas
Measuring principle unaffected by the gas composition
Inline flowmeter for measuring wet biogas and digester gas under fluctuating process conditions.
Device features:
Multivariable device: flow, temperature and methane
Medium temperature: 0 ~ 80 °C (32 ~ 176 °F)
Process pressure: 0.7 ~ 11 bar a (10.2 ~ 159 psi a)
Loop-powered technology
Rugged dual-compartment housing
Plant safety: global approvals
Spare Parts & Accessories 53
53 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| XPD0002- | Ultrasonic Flowmeter Electronic Module 200Main electronic module | Enquire |
| 71108602 | I/O moduleNon-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200. | Details |
| XPD0015- | I/O module, 2-wire, 4-20mA, HART, ExNon-Ex, Ex. 1x current output HART. | Enquire |
| XPD0016- | I/O module, 2-wire, 4-20mA, HART, PFS, ExNon-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output. | Enquire |
| XPD0018- | I/O moduleNon-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output. 1x current input. | Enquire |
| 71128617 | Overvoltage protector4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71128619 | Overvoltage protector4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71109658 | Display module kit, SD02, push buttonsFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Usage: Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover. | Details |
| XPD0024- | Display moduleFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover. | Enquire |
| 71162152 | Display module kit, SD03, touch controlFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover. | Details |
| XPD0025- | Display moduleFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover. | Enquire |
| 71197334 | Transmitter FHX50Consists of: electronics, ribbon cable. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass200, Prowirl 200, Promag 200, Prosonic Flow 200. | Details |
| 71296840 | Plug connector M12, VATo connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200. | Details |
| 71206552 | CableConnection cable, shielded. Usage: FHX50, FHX50B. | Details |
| 71206554 | CableConnection cable, shielded. Usage: FHX50, FHX50B. | Details |
| 71206555 | CableConnection cable, shielded. Usage: FHX50, FHX50B. | Details |
| 71206556 | CableConnection cable, shielded. Usage: FHX50, FHX50B. | Details |
| 71110280 | Terminal kit 2-wire, I/O moduleConsists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71110281 | Aluminum coverMaterial: 316L. O-ring, EPDM, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200. | Details |
| 71110282 | Aluminum coverMaterial: 316L. O-ring NBR, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67, FHX50. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200. | Details |
Configurator / Comparison
Accessories / Spare parts
Measuring principle video
Click to playSource:Endress+Hauserpublic information from the website
Diagnostic codes
Proline Prosonic Flow B 200(60 条)→数据摘自 Endress+Hauser 操作手册,含状态信号、可能原因与维修指导。
Case Studies
Municipal Wastewater Treatment · Ultrasonic flowmeter — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Ultrasonic flowmeter properly configured on the existing plant, with the aim of transit-time ultrasonic measurement of liquid or gas flow.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Ultrasonic flowmeter configuration has to involve checking straight runs, pipe internal condition and entrained gas.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant checking straight runs, pipe internal condition and entrained gas, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is clamp-on versions avoid pipe work, minimising shutdown in revamps, and the readings are now used for process tuning.
Food & Beverage · Ultrasonic flowmeter — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was transit-time ultrasonic measurement of liquid or gas flow.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking straight runs, pipe internal condition and entrained gas.
What We Did
We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around checking straight runs, pipe internal condition and entrained gas, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — clamp-on versions avoid pipe work, minimising shutdown in revamps, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Ultrasonic flowmeter — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Ultrasonic flowmeter, focusing on transit-time ultrasonic measurement of liquid or gas flow.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Ultrasonic flowmeter specification must therefore cover checking straight runs, pipe internal condition and entrained gas.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on checking straight runs, pipe internal condition and entrained gas, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — clamp-on versions avoid pipe work, minimising shutdown in revamps, with confidence in this measuring point improving markedly.
Power & Energy · Ultrasonic flowmeter — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Ultrasonic flowmeter; the focus is transit-time ultrasonic measurement of liquid or gas flow.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking straight runs, pipe internal condition and entrained gas.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on checking straight runs, pipe internal condition and entrained gas, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means clamp-on versions avoid pipe work, minimising shutdown in revamps, which cut the workload on the site maintenance team.
Related Products
Endress+HauserProsonic Flow 93T portable
Endress+HauserProsonic Flow 91WA1 Clamp On 1Ch/1Set
Endress+HauserUltrasonic concentration meter D9FB
Endress+HauserUltrasonic flowmeter 93W
Endress+HauserUltrasonic concentration meter D9IB
Endress+HauserUltrasonic flowmeter
Endress+HauserUltrasonic flowmeter 93P
Endress+Hauser