Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com
50E
Electromagnetic flowmeter
Promag E is a streamlined sensor for basic chemical applications. It is the most economical solution for our chemical customers. Combined with the proven Promag 50 transmitter with push buttons, Promag 50E offers accurate measurement of liquids for a wide range of standard applications. Promag 50E is available as compact or remote version.
Compare

Liquids

Measuring Principle
Product headline std_productprofile_product_usp_34675_1508941655.
Fully suitable for basic applications in the chemical and process industry.
Sensor features Cost-effective sensor – ideal solution for basic requirements. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Nominal diameter: max. DN 600 (24"). Ex approvals for Zone 2. Liner made of PTFE.
Transmitter features std_productprofile_product_benefits_34681_1508942231. std_productprofile_product_benefits_34683_1508942232. std_productprofile_product_benefits_34682_1508942239.
std_successorproducts_product_differentiating_tech_features_35305_1509527304. std_successorproducts_product_differentiating_tech_features_35308_1509527353. std_successorproducts_product_differentiating_tech_features_35309_1509527353.
Nominal diameter range DN 15 to 600 (½ to 24")
Wetted materials Liner: PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Measured variables Volume flow
Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
Max. process pressure PN 40, Class 150, 20K
Medium temperature range –10 to +110 °C (+14 to +230 °F)
Ambient temperature range –10 to +60 °C (+14 to +140 °F)
Sensor housing material AlSi10Mg, coated; carbon steel with protective coating
Transmitter housing material Powder‐coated die‐cast aluminum
Degree of protection Compact version: IP67, type 4X enclosure
Sensor remote version (standard): IP67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure
Transmitter remote version: IP67, type 4X enclosure
Display/Operation 2‐line backlit display with push buttons
Configuration via local display and operating tools possible
Outputs 3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency output (passive)
Switch output (passive)
Inputs Status input
Digital communication HART
PROFIBUS PA/DP
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, cCSAus
Product safety CE, C-tick, EAC marking
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Pressure approvals and certificates PED

The Promag E is a standard sensor for the chemical industry, providing chemical customers with the most economical solution. Used with the push-button Promag 50 transmitter, the Promag 50E provides high-precision liquid measurement in many standard applications. The Promag 50E is available as a compact or remote instrument.

 

Benefits

Economical sensor: the ideal solution for basic requirements

Energy-saving flow measurement: no pressure loss due to restriction of the pipe cross-section

Maintenance-free: no moving parts

Fast commissioning: application-specific quick setup

Operating safety: readable process information on the display

Fully complies with industrial standards: IEC/EN/NAMUR

 

Application areas

Bidirectional measuring principle unaffected by pressure, density, temperature and viscosity

Fully suitable for basic applications in the chemical and process industries

Device features

 

Nominal diameter: max. DN 600 (24") (four-wire); nominal diameter: max. DN 200 (8") (two-wire)

PTFE liner

Two-line backlit display with pushbutton operation

Available as compact or remote instrument

HART, PROFIBUS DP/PA communication

Spare Parts & Accessories 66

66 spare parts · click to collapse
Order codeDescription
50096745*** Power Supply BoardKit power s.b. PMAG5X 85-260VACDetails
71039466*** Power Supply BoardHE = harsh environmentDetails
50096747Kit PSB 50/51/53 20-55VAC 16-62VDCDetails
71039468*** Power Supply BoardHE = harsh environmentDetails
50094002fuseKit 10 fuses 250 VAC T800 MADetails
50094003fuseKit Bus/connec.b.5X/40/8X/65 field hous.Details
50106079*** Amplifier BoardLanguage: FR, ES, IT, NL, PT, DE, ENDetails
71039448*** Amplifier BoardLanguage: FR, ES, IT, NL, PT, DE, EN HE = harsh environmentDetails
50106081*** Amplifier BoardLanguage: JA, ID, ENDetails
71039450*** Amplifier BoardLanguage: JA, ID, EN HE = harsh environmentDetails
50106080*** Amplifier BoardLanguage: SV, FI, NO, RU, PL, CS, ENDetails
71039449*** Amplifier BoardLanguage: SV, FI, NO, RU, PL, CS, EN HE = harsh environmentDetails
50106073*** Amplifier BoardLanguage: FR, ES, IT, NL, PT, DE, ENDetails
71039445*** Amplifier BoardLanguage: FR, ES, IT, NL, PT, DE, EN HE = harsh environmentDetails
50106075*** Amplifier BoardLanguage: JA, ID, ENDetails
71039447*** Amplifier BoardLanguage: JA, ID, EN HE = harsh environmentDetails
50106074*** Amplifier BoardLanguage: SV, FI, NO, RU, PL, CS, ENDetails
71039446*** Amplifier BoardLanguage: SV, FI, NO, RU, PL, CS, EN HE = harsh environmentDetails
50096759Explosion-proof current, frequency and status input/output moduleKit com50/51/40/80/90 I+F/stat.in+outExDetails
71039473*** Input/Output BoardHE = harsh environmentDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source: public information from the Endress+Hauser website

Measuring principle video

Click to play
All documents for this model
4 documents · click to expand
BA

Proline Promag 50 HART Operating Instructions English

HART Rev. 1717 134 pages
Preview
BA

Proline Promag 50 PROFIBUS DP/PA Operating Instructions English

PROFIBUS-DP Rev. 1717 156 pages
Preview
TI

技术资料 Proline Promag 50E Chinese

Rev. 0114 40 pages
Preview
TI

Proline Promag 50E Technical Information English

Rev. 0217 39 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Electromagnetic flow meter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was volumetric flow of conductive liquids.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing liner and electrode pairing by conductivity, solids and abrasion.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing liner and electrode pairing by conductivity, solids and abrasion, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no obstruction, so pressure loss is minimal and upkeep low, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Electromagnetic flow meter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Electromagnetic flow meter, focusing on volumetric flow of conductive liquids.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Electromagnetic flow meter specification must therefore cover choosing liner and electrode pairing by conductivity, solids and abrasion.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing liner and electrode pairing by conductivity, solids and abrasion, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no obstruction, so pressure loss is minimal and upkeep low, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Electromagnetic flow meter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Electromagnetic flow meter; the focus is volumetric flow of conductive liquids.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing liner and electrode pairing by conductivity, solids and abrasion.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing liner and electrode pairing by conductivity, solids and abrasion, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no obstruction, so pressure loss is minimal and upkeep low, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Electromagnetic flow meter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Electromagnetic flow meter and the core task is volumetric flow of conductive liquids.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Electromagnetic flow meter cannot be specified generically — it calls for choosing liner and electrode pairing by conductivity, solids and abrasion.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing liner and electrode pairing by conductivity, solids and abrasion, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no obstruction, so pressure loss is minimal and upkeep low.