Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

55S Electromagnetic flowmeter

55S Electromagnetic flowmeter
Electromagnetic flowmeter
Configurable Models 10 models
Promag S is the specialist for inhomogeneous, abrasive and corrosive fluids. The robust sensor design, featuring industry-optimized liners, enables its use in most challenging surroundings and metering jobs such as sewage treatment, pulp and paper production or in the primaries and metals industry. Due to its high-performance transmitter, Promag 55S not only measures flow reliably, but also calculates solids content at low maintenance requirements.
Compare

Liquids

Measuring Principle Electromagnetic
Product headline The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics.
Superb signal stability due to unique signal processing.
Ideal for the most demanding applications with high solids content and high abrasion.
Sensor features Maximum safety – industry-optimized measuring electrodes and linings. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Intensified coil system. Large range of liners. Solids content up to 80 % by weight.
Transmitter features Highest performance – with integrated solids measurement for demanding fluids. Highest safety – integrated electrode cleaning. Automatic recovery of data for servicing.
4-line backlit display with touch control. Two switch outputs. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus.
Nominal diameter range DN 15...600
1/2"...24"
Wetted materials Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber
Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum
Measured variables Volume flow, electrical conductivity, mass flow
Max. measurement error Volume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range 0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)
Max. process pressure PN 40, Cl. 300, JIS 20 K
Medium temperature range 0 to +60 °C (+32 to +140 °F), 0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F), –20 to +180 °C (–4 to +356 °F), –20 to +150 °C (–4 to +266 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material Aluminum coated AlSi10Mg, carbon steel with protective varnish
Transmitter housing material Powder-coated die-cast aluminum
Degree of protection Standard: IP 67 (Type 4X enclosure) for transmitter and sensor
Optional: IP 68 (Type 6P enclosure) for remote version of Promag S sensor
Display/Operation Liquid-crystal display: illuminated, four lines with 16 characters per line
Onsite operation with three optical sensor keys
Outputs 4...20mA
(active/passive) Pulse-/ Frequency output (active/passive)
Two status outputs
Inputs Status
Current input
Digital communication HART, PROFIBUS DP/PA, FOUNDATION Fieldbus
Power supply AC 20 to 260 V
DC 20 to 64 V
Hazardous area approvals ATEX, FM, CSA, UK Ex
Product safety CE, C-tick, EAC marking
Pressure approvals and certificates CRN, PED
Material certificates 3.1 material
Hygienic approvals and certificates Drinking water approval:ACS, KTW-BWGL, NSF 61, WRAS BS 6920

The Promag 55S is designed for non-uniform, abrasive and corrosive fluids. The sensor uses an industry-optimized liner and is rugged, suitable for the most challenging environments and metering applications, such as wastewater treatment, pulp and paper, and primary raw materials and metallurgy. The Promag 55S is equipped with a high-performance transmitter that not only measures flow reliably but also calculates the solids content with low maintenance requirements.

Benefits:

  • Unique signal processing, outstanding signal stability

  • Highest safety factor - industry-optimized measuring electrodes and liner

  • Energy-saving flow measurement - cross-section identical to the pipe, no pressure loss

  • Best performance - for demanding fluids, with built-in solids content detection

  • Highest safety level - integrated electrode cleaning

  • Automatic data recovery for easy maintenance

  • Maintenance-free - no moving parts

Application areas:

  • Bidirectional measuring principle not limited by pressure, density, temperature or viscosity

  • Ideal for measuring media with high solids content and high abrasiveness

Instrument features

  • Reinforced coil system

  • Wide range of optional liners

  • Solids content up to 80 % by weight

  • Four-line backlit display with touch control

  • Two switch outputs

  • HART, PROFIBUS PA/DP, FOUNDATION Fieldbus

Spare Parts & Accessories 89

89 spare parts · click to collapse
Order codeDescription
71029347full-range power supply board85-260VAC 20-55VAC 20-64 VDCDetails
71039470Full-Range Power Supply HE Power Supply Board85-260VAC 20-55VAC 20-64 VDC HE = harsh environmentDetails
50094003fuseKit Bus/connec.b.5X/40/8X/65 field hous.Details
71029343amplifier boardLanguage: FR,ES,IT,NL,PT,DE,ENDetails
71039462amplifier boardLanguage: FR, ES, IT, NL, PT, DE, EN HE = harsh environmentDetails
71029344amplifier boardLanguage: SV,FI,NO,RU,PL,CS,ENDetails
71039463amplifier boardLanguage: SV, FI, NO, RU, PL, CS, EN HE = harsh environmentDetails
71029345amplifier boardLanguage: JA,ID,ENDetails
71039464amplifier boardLanguage: JA, ID, EN HE = harsh environmentDetails
71029346amplifier boardLanguage: ZH,ENDetails
71039465amplifier boardLanguage: ZH, EN HE = harsh environmentDetails
71704637Measuring amplifier kit, 55S, non-hazardous, WEADetails
71704641Measurement amplifier kit, 55S, N-haz, WEA, HEHE = harsh environmentDetails
71704638Measurement amplifier kit, 55S, N-haz, ESSDetails
71704642Measuring amplifier kit, 55S, N-haz, ESS, HEHE = harsh environmentDetails
71704639Measurement amplifier kit, 55S, non-hazardous, SEADetails
71704643Measurement amplifier kit, 55S, non-hazardous, SEA, HEHE = harsh environmentDetails
71704640Measuring amplifier kit, 55S, non-hazardous, CNDetails
71704644Measuring amplifier kit, 55S, non-hazardous area, CN, HEHE = harsh environmentDetails
50098300Explosion-proof Current/Frequency Input Module with 2-Channel Relay OutputKit com 53/83/93/65 curr/freq/2Relay ExDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play

Source: public information from the Endress+Hauser website

10 models · click to collapse
All documents for this model
12 documents · click to expand
BA

Proline Promag 55 English

Rev. 1525 120 pages
Preview
BA

Proline Promag 55 PROFIBUS DP/PA Operating Instructions English

PROFIBUS-DP Rev. 1525 158 pages
Preview
BA

Proline Promag 55 FOUNDATION Fieldbus Operating Instructions English

FOUNDATION-Fieldbus Rev. 1425 116 pages
Preview
BA

Proline Promag 55 PROFIBUS DP/PA Description of Device Functions English

PROFIBUS-DP Rev. 1425 144 pages
Preview
BA

Proline Promag 55 English

Rev. 1325 166 pages
Preview
BA

Proline Promag 55 FOUNDATION Fieldbus Description of Device Functions English

FOUNDATION-Fieldbus Rev. 1325 174 pages
Preview
BA

Proline Promag 55 English

Rev. 1009 126 pages
Preview
BA

Proline Promag 55 English

Rev. 1009 166 pages
Preview
BA

Proline Promag 55 FOUNDATION Fieldbus Description of Device Functions English

FOUNDATION-Fieldbus Rev. 0709 174 pages
Preview
BA

Proline Promag 55 FOUNDATION Fieldbus Operating Instructions English

FOUNDATION-Fieldbus Rev. 0709 120 pages
Preview
BA

Proline Promag 55 PROFIBUS DP/PA Operating Instructions English

PROFIBUS-DP Rev. 0610 162 pages
Preview
BA

Proline Promag 55 PROFIBUS DP/PA Description of Device Functions English

PROFIBUS-DP Rev. 0610 140 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Electromagnetic flow meter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was volumetric flow of conductive liquids.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing liner and electrode pairing by conductivity, solids and abrasion.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing liner and electrode pairing by conductivity, solids and abrasion, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no obstruction, so pressure loss is minimal and upkeep low, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Electromagnetic flow meter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Electromagnetic flow meter, focusing on volumetric flow of conductive liquids.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Electromagnetic flow meter specification must therefore cover choosing liner and electrode pairing by conductivity, solids and abrasion.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing liner and electrode pairing by conductivity, solids and abrasion, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no obstruction, so pressure loss is minimal and upkeep low, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Electromagnetic flow meter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Electromagnetic flow meter; the focus is volumetric flow of conductive liquids.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing liner and electrode pairing by conductivity, solids and abrasion.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing liner and electrode pairing by conductivity, solids and abrasion, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no obstruction, so pressure loss is minimal and upkeep low, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Electromagnetic flow meter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Electromagnetic flow meter and the core task is volumetric flow of conductive liquids.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Electromagnetic flow meter cannot be specified generically — it calls for choosing liner and electrode pairing by conductivity, solids and abrasion.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing liner and electrode pairing by conductivity, solids and abrasion, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no obstruction, so pressure loss is minimal and upkeep low.