5BH Filling electromagnetic flowmeter

5BH Filling electromagnetic flowmeter
Filling electromagnetic flowmeter 5BH
Dosimag is specially designed for filling and bottling applications of conductive liquids. It measures volume directly. Designed for applications where space is a premium, Dosimag will be the preferred choice for system integrators, skid builders and equipment manufacturers.
Compare

Liquids

Measuring Principle Electromagnetic
Product headline Flowmeter with hygienic design, highest repeatability and an ultra-compact sensor.
For demanding dosing and filling applications.
Sensor features High process safety – high measuring accuracy and repeatability in shortest filling time. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Wetted materials CIP, SIP cleanable. Nominal diameter: DN 4 to 25 (¹⁄₈ to 1"). Measuring device conform to FDA.
Transmitter features Versatile and time-saving wiring – plug connector. Industry-optimized – ultra-compact design. For hygienic requirements – stainless steel housing.
Pulse/frequency/switch output, Modbus RS485. Custody transfer approvals (MID, NTEP). Excellent, easily cleanable transmitter.
Nominal diameter range DN 4 (⁵⁄₃₂"), 8 (⁵⁄₁₆"), 15 (½"), 25 (1")
Wetted materials Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum,
Platinum
Measured variables Volume flow
Max. measurement error ±0.25 % o.r. ± 1 to 4 m/s (3.3 to 13 ft/s)
±0.5 % o.r. ± 1 mm/s (0.04 in/s)
±5 % o.r.
Measuring range 0.14 to 1.66 l/s (0.035 to 0.44 gal/s)
Max. process pressure PN 16
Medium temperature range Seal material EPDM: –20 to +130 °C (–4 to +266 °F)
Seal material Silicone: –20 to +130 °C (–4 to +266 °F)
Seal material Viton: 0 to +150 °C (+32 to +302 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4308 (304)
Transmitter housing material 1.4308 (304)
Degree of protection IP66/67, type 4X enclosure
Display/Operation No local Operation
Configuration via operating tools possible
Outputs Pulse/frequency/switch output (passive)
Inputs None
Digital communication Modbus RS485
Power supply DC 20 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus
Product safety CE
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc.to ISO/IEC 17025)
NTEP
Material certificates 3.1 material
Hygienic approvals and certificates Sanitary approval: 3-A, EHEDG, seals acc. to FDA

Dosimag is designed specifically for filling and bottling of conductive liquids and measures the volume flow directly. Designed for compact application spaces, Dosimag is the preferred product for system integrators, skid manufacturers and equipment manufacturers.

Advantages
High process safety - high measuring accuracy and repeatability within the shortest filling times
Energy-efficient flow measurement - cross-section identical to the pipe, no pressure loss
Maintenance-free - no moving parts
Versatile and convenient wiring - plug connection
Industry-optimized - ultra-compact design
Hygienic - stainless steel housing

Application
The bidirectional measuring principle is not affected by pressure, density, temperature or viscosity
Suitable for batching and filling applications
Device properties
Wetted materials suitable for CIP and SIP cleaning
Nominal diameter: DN 4 to 25 (1/8 to 1")
Measuring device complies with FDA
Pulse/frequency/switch output, Modbus RS485
Custody transfer approval (MID, NTEP)
Excellent transmitter functions, easy to clean

 

Spare Parts & Accessories 16

16 spare parts · click to collapse
Order codeDescription
5BXXX-*** canned electromagnetic flowmeter transmitter, OEM type 5BXXXEnquire
50102857Sensor/Transmitter GasketDetails
50106443FXA commissioning toolFXA service adapter Batchline packedDetails
710358095BH Commissioning Cable, Y-Type CableDetails
50107167Adapter RSE4 8-pole -> 4-pole, 4-wireDetails
50107168adapterDetails
50107169Adapter RSE8 8-pin -> 8-pin, 5-wireDetails
50107895Connecting cable RKWTN8-56/5 P92, 5 mCaution: Please note that this cable is not approved for use in ATEX Zone 2 or UL Class 1 Division 2 areas. This cable is not shielded. Use a shielded twisted pair cable for Modbus RS485 applications.Details
71306290Terminator resistor kit CAN-M12 5P A-codDetails
51516983Communication interface FXA291Serial USB Computer Interface Technical Data: - USB Version1.1 or higher - Power supply via USB - IP51; NEMA/Typ 3 - Ambient temperature: -20....+60oC - Ex: II(2) G (EEx ia) II C - ATEX: BVS 05 ATEX E 095 Scope of deliovery: Commubox FXA 291 MS Windows USB driver Device is submitted for CSA/FM application. The device may not be modified and may be used with intrinsically safe circuits with corresponding characteristics only (see safety certificate).Details
5BH-Dosimag, 5BHElectromagnetic flowmeter for filling applications (compact version) PFA measuring tube lining Housing in stainless steelEnquire
DKH-Promag H Installation Kit DKHA set includes 2 process connections and 2 seals.Enquire
DK5G-Seal ring assemblyEnquire
DK5HW-Welding Assembly DK5HWEnquire
DK5HA-Adapter assembly DK5HAReplacement of sensor Promag A or Promag H DN 25. The set includes 2 adapters and 2 seals. For dimensions refer to the technical documentation.Enquire
FXA193-*** Communication Interface FXA193The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC. - Service Softw.ToF Tool-Fieldtool PackageEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Electromagnetic flow meter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was volumetric flow of conductive liquids.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing liner and electrode pairing by conductivity, solids and abrasion.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing liner and electrode pairing by conductivity, solids and abrasion, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no obstruction, so pressure loss is minimal and upkeep low, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Electromagnetic flow meter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Electromagnetic flow meter, focusing on volumetric flow of conductive liquids.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Electromagnetic flow meter specification must therefore cover choosing liner and electrode pairing by conductivity, solids and abrasion.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing liner and electrode pairing by conductivity, solids and abrasion, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no obstruction, so pressure loss is minimal and upkeep low, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Electromagnetic flow meter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Electromagnetic flow meter; the focus is volumetric flow of conductive liquids.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing liner and electrode pairing by conductivity, solids and abrasion.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing liner and electrode pairing by conductivity, solids and abrasion, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no obstruction, so pressure loss is minimal and upkeep low, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Electromagnetic flow meter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Electromagnetic flow meter and the core task is volumetric flow of conductive liquids.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Electromagnetic flow meter cannot be specified generically — it calls for choosing liner and electrode pairing by conductivity, solids and abrasion.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing liner and electrode pairing by conductivity, solids and abrasion, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no obstruction, so pressure loss is minimal and upkeep low.