Technical Data
CompareLiquids
| Measuring Principle | |
| Product headline | std_productprofile_product_usp_8041. For basic water applications, optimized for limited space and plastic pipe installations. |
| Sensor features | Easy, fast centering of the sensor – innovative housing construction. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. std_productprofile_product_differentiating_tech_features_6675. std_productprofile_product_differentiating_tech_features_6676. std_productprofile_product_differentiating_tech_features_6677. |
| Transmitter features | Safe operation – no need to open the device due to display with touch control, background lighting. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Transmitter housing made of durable polycarbonate or aluminium. WLAN access. Integrated data logger: measured values monitoring. |
| Nominal diameter range | DN 25...100 1"...4" |
| Wetted materials | Liner: Polyamide Electrodes: 1.4435 (316L) |
| Measured variables | Volume flow, mass flow |
| Max. measurement error | Volume flow: ±0.5 % o.r. ± 1 mm/s (0.04 in/s) |
| Measuring range | 9 to 4700 dm³/min (2.5 to 1250 gal/min) |
| Max. process pressure | PN 16, Class 150, 10K |
| Medium temperature range | 0 to +60 °C (+32 to +140 °F) |
| Ambient temperature range | –20 to +60 °C (–4 to +140 °F) |
| Sensor housing material | AlSi10Mg, coated Sensor connection housing: AlSi10Mg, coated |
| Transmitter housing material | Polycarbonat; AlSi10Mg, coated |
| Degree of protection | Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, Type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display, web browser and operating tools possible |
| Outputs | 3 ouputs: 0‐20 mA/4‐20 mA HART (active) Pulse/frequency/switch output (passive) Pulse/frequency output (passive) Switch output (passive) |
| Inputs | Status input |
| Digital communication | HART, PROFIBUS DP, EtherNet/IP, Modbus RS485 |
| Power supply | AC 100 to 240 V / AC/DC 24 V |
| Hazardous area approvals | cCSAus |
| Product safety | CE, C-tick, EAC marking |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Pressure approvals and certificates | CRN |
| Hygienic approvals and certificates | ACS, KTW-BWGL, NSF 61, WRAS BS 6920 |
The Promag D wafer flowmeter is designed specifically for basic water industry applications where space is limited. The innovative housing design enables customization and fast centering while optimizing installation costs. Promag D 400 is equipped with a powerful transmitter, is suitable for the water and wastewater industry and significantly reduces time and costs. In addition, Heartbeat Technology ensures reliable measurement and compliance verification.
Benefits
Simple and fast centering of the sensor, innovative housing design
Energy-saving flow measurement - cross-section identical to the pipe, no pressure loss
Maintenance-free - no moving parts
Safe operation - backlit display, touch control, no need to open the housing for operation
Localized operation without additional hardware or software, saving time - integrated web server
Integrated verification – Heartbeat Technology
Application
Bidirectional measuring principle, independent of pressure, density, temperature and viscosity
Basic water industry applications: suitable for measurement in confined spaces and in plastic pipes
Device features
Short installation length and low device weight
With stainless steel grounding ring
Certified for international drinking water measurement
Transmitter housing made of polycarbonate or aluminum
WLAN connection
Integrated data logger for measured value monitoring
Spare Parts & Accessories 37
37 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| XPD0014- | Electronic module Promag 400 Index CComplete main electronic module or power supply, I/O-board and amplifier as individual boards. Complete main electronic module contains: Power supply, I/O-board, amplifier, board carrier, terminal connection, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminal connection/ I/O-board incl. terminal connection/ Amplifier incl. ribbon cable. | Enquire |
| XPD0014- | Electronic module Promag 400 Index CComplete main electronic module or power supply, I/O-board and amplifier as individual boards. Complete main electronic module contains: Power supply, I/O-board, amplifier, board carrier, terminal connection, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminal connection/ I/O-board incl. terminal connection/ Amplifier incl. ribbon cable. | Enquire |
| XPD0040- | Electromagnetic 400 Index C UpgradeComplete main electronic module or power supply, I/O module with amplifier as individual boards. Complete main electronic module contains: Power supply, I/O module, amplifier, board carrier, terminals, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminals/ I/O module incl. terminal connection and amplifier incl. ribbon cable. | Enquire |
| XPD0040- | Electromagnetic 400 Index C UpgradeComplete main electronic module or power supply, I/O module with amplifier as individual boards. Complete main electronic module contains: Power supply, I/O module, amplifier, board carrier, terminals, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminals/ I/O module incl. terminal connection and amplifier incl. ribbon cable. | Enquire |
| XPD0040- | Electromagnetic 400 Index C UpgradeComplete main electronic module or power supply, I/O module with amplifier as individual boards. Complete main electronic module contains: Power supply, I/O module, amplifier, board carrier, terminals, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminals/ I/O module incl. terminal connection and amplifier incl. ribbon cable. | Enquire |
| XPD0040- | Electromagnetic 400 Index C UpgradeComplete main electronic module or power supply, I/O module with amplifier as individual boards. Complete main electronic module contains: Power supply, I/O module, amplifier, board carrier, terminals, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminals/ I/O module incl. terminal connection and amplifier incl. ribbon cable. | Enquire |
| XPD0017- | Display module 4-wire, 400 Index CUsage: Promag 400 Index C, Prosonic Flow 400 Index B. | Enquire |
| 71228789 | terminal blockUsage: Prosonic Flow 400, Promag 400(C), (C) = generation index C. Consists of: Connection terminal 3-Pol stamp 1,2, Connection terminal 2-Pol stamp A,B, Connection terminal 4-Pol stamp 20-23, Connection terminal 4-Pol stamp 24-26. | Details |
| 71228791 | Integrated Connection Plate AssemblyUsage: Promag 400(C) with sensor D. (C) = generation index C. | Details |
| 71228790 | Split-Type Connection Board AssemblyUsage: Promag 400(C) with sensor D/L/W. (C) = generation index C. | Details |
| 50098018 | sensor terminal boardUsage: 10/50/51/53/55/400/800 | Details |
| 71185788 | T-DAT module | Details |
| 71443262 | *** coverUsage: Promag 400 (C) (C) = generation index C. Consists of: Version 1: cover polycarbonate complete, 2x hinge pin L= 58mm plastic. Version 2: cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, wire with screw lock 1,5x150. | Details |
| 71408508 | housing coverUsage: Promag/Prosonic Flow 400, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 800(C), (C) = generation index C, transmitter housing polycarbonate. Consists of: cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150. | Details |
| 71384170 | Promag400/500 coverUsage: Prosonic Flow 400, Promag 400(C), (C) = generation index C, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,40x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150. | Details |
| 50094038 | Terminal compartment cover10/5X/40/8X/93/65/92F | Details |
| 71247838 | Maintenance cover, separate typeUsage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease | Details |
| 71278077 | Polycarbonate cover gasketUsage: Prosonic Flow 400, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 400/800(C), (C) = generation index C, transmitter housing polycarbonate. Consists of: 10x O-Ring 196,44x3,53 VMQ. | Details |
| 71278078 | cover seal ringUsage: Prosonic Flow 400, Promag 400(C), (C) = generation index C, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, transmitter housing Alu. Consists of: 10x O-Ring 196,40x3,53 VMQ, default and -50oC/-58oF. | Details |
| 71228793 | Housing seal kitUsage: Promag 400(C) with sensor D/L/W. (C) = generation index C. Consists of: Gasket HNBR for housing/sensor D/L/W. O-Ring 29,87x1,78 HNBR for sensor- plug L/W. | Details |
Configurator / Comparison
Source:Endress+Hauserwebsite public information
Measuring principle video
Click to play10 documents · click to expand
Proline Promag D 400 HART 操作手册 Chinese
Proline Promag D 400 工业以太网(EtherNet/IP) 操作手册 Chinese
Proline Promag D 400 PROFIBUS DP 操作手册 Chinese
Proline Promag D 400 Modbus RS485 操作手册 Chinese
Proline Promag D 400 HART Operating Instructions English
Proline Promag D 400 EtherNet/IP Operating Instructions English
Proline Promag D 400 PROFIBUS DP Operating Instructions English
Proline Promag D 400 Modbus RS485 Operating Instructions English
Proline Promag D 400 技术资料 Chinese
Proline Promag D 400 Technical Information English
Case Studies
Municipal Wastewater Treatment · Electromagnetic flow meter — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was volumetric flow of conductive liquids.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing liner and electrode pairing by conductivity, solids and abrasion.
What We Did
We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing liner and electrode pairing by conductivity, solids and abrasion, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — no obstruction, so pressure loss is minimal and upkeep low, with routine maintenance falling noticeably.
Food & Beverage · Electromagnetic flow meter — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Electromagnetic flow meter, focusing on volumetric flow of conductive liquids.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Electromagnetic flow meter specification must therefore cover choosing liner and electrode pairing by conductivity, solids and abrasion.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing liner and electrode pairing by conductivity, solids and abrasion, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — no obstruction, so pressure loss is minimal and upkeep low, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · Electromagnetic flow meter — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Electromagnetic flow meter; the focus is volumetric flow of conductive liquids.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing liner and electrode pairing by conductivity, solids and abrasion.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing liner and electrode pairing by conductivity, solids and abrasion, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means no obstruction, so pressure loss is minimal and upkeep low, which cut the workload on the site maintenance team.
Power & Energy · Electromagnetic flow meter — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Electromagnetic flow meter and the core task is volumetric flow of conductive liquids.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Electromagnetic flow meter cannot be specified generically — it calls for choosing liner and electrode pairing by conductivity, solids and abrasion.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing liner and electrode pairing by conductivity, solids and abrasion, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is no obstruction, so pressure loss is minimal and upkeep low.
Related Products
Endress+HauserElectromagnetic flowmeter
Endress+HauserElectromagnetic flowmeter 10
Endress+HauserElectromagnetic flowmeter
Endress+HauserElectromagnetic flowmeter
Endress+HauserBattery-powered electromagnetic flowmeter
Endress+HauserMAGPHANT
Endress+HauserElectromagnetic flowmeter
Endress+Hauser