5H1B Electromagnetic flowmeter

5H1B Electromagnetic flowmeter
Electromagnetic flowmeter 5H1B
Configurable Models 1 models
Promag H is the preferred sensor for hygienic applications with highest requirements in the food and beverage and life sciences industries. The ultra-compact transmitter provides full performance on the smallest footprint and enables seamless system integration, making Promag H 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology ensures compliance and process safety at all times.
Compare

Liquids

Measuring Principle Electromagnetic
Product headline Specialist for hygienic applications with an ultra-compact transmitter.
Multivariable measurement of flow, temperature and conductivity.
Dedicated to demanding applications in the food and beverage as well as in life sciences industries.
Sensor features Flexible installation concept – numerous hygienic process connections. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Integrated temperature measurement. Sensor housing made of stainless steel (3-A, EHEDG). Wetted materials CIP, SIP cleanable.
Transmitter features Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. High degree of protection: IP69. Local display available.
Nominal diameter range DN 2 to 150 (¹⁄₁₂ to 6")
Wetted materials Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum
Measured variables Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected
conductivity
Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option) ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range 0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)
Max. process pressure PN 40, Class 150, 20K
Medium temperature range –20 to +150 °C (–4 to +302 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Compact: AlSi10Mg, coated
Compact/ultra‐compact: 1.4301 (304)
Degree of protection Standard: IP66/67, type 4X enclosure
Option: IP69
Display/Operation 4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
Power supply DC 20 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, EAC
Product safety CE, C-tick
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Verification: Heartbeat Technology complies with requirements for traceable verification according to ISO 9001:2008, chapter 7.6. a (TUV attestation)
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP

The Promag H sensor is particularly suitable for hygienic applications and meets the highest requirements in the food & beverage and life sciences industries. Combined with the compact transmitter, Promag H 300 offers flexible operation and convenient system integration: wiring on the same side of the instrument, remote display and improved connection options. Heartbeat Technology always ensures compliance and process safety.

Advantages
Flexible installation: a wide range of hygienic process connections
Energy-saving flow measurement: no pressure loss thanks to the absence of flow restrictors
Maintenance-free: no moving parts
Complete access to process and diagnostic information: a wide range of user-configurable input/output combinations and fieldbuses
Reduced complexity and variety: user-configurable input/output functions
Integrated verification: built-in Heartbeat Technology

Application areas
Bidirectional measuring principle unaffected by pressure, density, temperature and viscosity.
Suitable for demanding applications in the food & beverage and life sciences industries.
Instrument features
PFA liner
Stainless steel sensor housing (3-A approval, EHEDG tested)
Wetted-part materials resistant to CIP and SIP cleaning
Compact hygienic dual-compartment housing, IP69, with up to 3 inputs/outputs
Backlit display, touch control and WLAN access
Remote display unit available

 

Spare Parts & Accessories 28

28 spare parts · click to collapse
Order codeDescription
XPD0010-Electromagnetic flowmeter electronic module 100Main electronic moduleEnquire
XPD0023-Display moduleUsage: Promag 100, Promass 100, Prosonic Flow E 100.Enquire
71185788T-DAT moduleDetails
71185789Aluminum meter coverUsage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: Cover Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.Details
71185790Stainless Steel CoverUsage: Promass 100, Promag 100, Prosonic Flow 100. Consists of: Cover stainless 1.4301. Gasket EPDM for cover.Details
71185793Stainless Steel CoverUsage: Promag/Promass 100, Promag/Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket EPDM for cover.Details
71266334Aluminum Cover Assembly, Glass Window, IntegratedUsage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat. Consists of: Cover with sight glass Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.Details
71266335Aluminum Cover Assembly, Glass Window, IntegratedUsage: Promass 100, Promag 100, Prosonic Flow 100. Consists of: Cover with sight glass stainless 1.4301. Gasket EPDM for cover.Details
71266337Aluminum cover assembly, glass window, ultra-compactUsage: Promass 100, Promag 100. Consists of: Cover with sight glass stainless 1.4301. Gasket EPDM for cover.Details
71211571Housing Gasket AssemblyUsage: Promag 100. Consists of: O-Ring 113,90 x 3,53 NBR for cover. Gasket HNBR for housing/sensor H. Gasket HNBR for housing/sensor E/P. O-Ring 29,87 x 1,78 HNBR for sensor connector.Details
71211572Housing Gasket AssemblyUsage: Promag 100. Consists of: Gasket EPDM for cover. Gasket HNBR for housing/sensor H. O-Ring 29,87 x 1,78 HNBR for sensor connector.Details
71211573gasketUsage: Promag 100, Promag 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket HNBR for housing/sensor H, O-Ring 29,87x1,78 HNBR for sensor plug.Details
50098036Explosion-proof cable glandKit 10 cable glands M20x1.5 ExDetails
71069285cable gland assemblyDetails
50098041adapterKit 10 extension M20x1.5/G 1/2"Details
71185802cable gland assemblyConsists of: 2 x Extension M20x1,5/G1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug G1/2".Details
50098042adapterKit 10 extension M20x1.5/NPT 1/2"Details
71185800cable gland assemblyConsists of: 2 x Extension M20x1,5/NPT1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug NPT1/2".Details
71276494Clamp fastening, screwsUsage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass, Promag/Promass 500, Promag 10, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover clamp, screw M4x16.Details
DKH-Promag H Installation Kit DKHA set includes 2 process connections and 2 seals.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

   

Measuring principle video

Click to play

Source:Endress+Hauserpublic information from the website

1 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Electromagnetic flow meter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was volumetric flow of conductive liquids.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing liner and electrode pairing by conductivity, solids and abrasion.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing liner and electrode pairing by conductivity, solids and abrasion, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no obstruction, so pressure loss is minimal and upkeep low, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Electromagnetic flow meter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Electromagnetic flow meter, focusing on volumetric flow of conductive liquids.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Electromagnetic flow meter specification must therefore cover choosing liner and electrode pairing by conductivity, solids and abrasion.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing liner and electrode pairing by conductivity, solids and abrasion, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no obstruction, so pressure loss is minimal and upkeep low, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Electromagnetic flow meter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Electromagnetic flow meter; the focus is volumetric flow of conductive liquids.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing liner and electrode pairing by conductivity, solids and abrasion.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing liner and electrode pairing by conductivity, solids and abrasion, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no obstruction, so pressure loss is minimal and upkeep low, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Electromagnetic flow meter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Electromagnetic flow meter and the core task is volumetric flow of conductive liquids.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Electromagnetic flow meter cannot be specified generically — it calls for choosing liner and electrode pairing by conductivity, solids and abrasion.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing liner and electrode pairing by conductivity, solids and abrasion, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no obstruction, so pressure loss is minimal and upkeep low.