Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

5HBB Electromagnetic flowmeter 10

5HBB Electromagnetic flowmeter 10
Electromagnetic flowmeter 10
Configurable Models 4 models
Promag H is the preferred sensor for hygienic applications in the food and beverage and life sciences industries. With its straightforward hard- and software design, Promag H 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology ensures measurement reliability and enables extension of recalibration cycles.
Compare

Liquids

Measuring Principle Electromagnetic
Product headline Flowmeter for basic hygienic applications with easy-to-use operation concept.
For applications with sanitary requirements.
Sensor features Flexible installation concept – numerous hygienic process connections. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts.
Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG). Wetted materials CIP-/SIP-cleanable.
Transmitter features Optimum usability – display with touch screen (HART and Modbus RS485 communication only) or operation with mobile devices and SmartBlue app. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485, IO-Link. Flexible operation with app and optional display.
Nominal diameter range DN 2 to 150 (¹⁄₁₂ to 6")
Wetted materials Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: aseptic molded seal (EPDM, FKM, silicone)
Measured variables Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected
conductivity
Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range 0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)
Max. process pressure PN 40, Class 150, 20K
Medium temperature range –20 to +150 °C (–4 to +302 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated
Degree of protection Standard: IP66/67, type 4X enclosure
Display/Operation 2.4" LCD display with touch & auto rotate; Configuration and operation via Bluetooth technology possible
Outputs 4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA
Digital communication HART, MODBUS RS485, IO-Link
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals CSA, GP, KC
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP

Benefits
Flexible installation: various hygienic process connections available
Energy-saving flow measurement: no flow restriction, no pressure loss
Maintenance-free: no moving parts
Optimum operability: install the SmartBlue app on a mobile device for direct touchscreen operation
Simple, efficient commissioning: guided instrument configuration presets and on-site setup
Self-verification: uses Heartbeat Technology

Applications
The Promag H sensor is the ideal choice for hygienic applications in the food & beverage and life sciences industries. The hardware and software of the Promag H 10 are intuitively designed, greatly simplifying every step of the instrument throughout its entire lifecycle, from design to service, while ensuring Endress+Hauser quality. Heartbeat Technology ensures measurement reliability and extends the calibration interval of the instrument.
Bidirectional flow measurement, completely unaffected by pressure, density, temperature and viscosity.
Meets the requirements of hygienic applications.
Device features
PFA liner
Stainless steel sensor housing (3-A approval, EHEDG tested)
Wetted part materials withstand CIP/SIP processes
Supports HART or Modbus RS485 system integration
Install the app and optional display unit for flexible operation

 

Spare Parts & Accessories 51

51 spare parts · click to collapse
Order codeDescription
XPD0060-sensor electronics moduleUsage: Promag 10. Consists of: ISEM (sensor electronic module) V316-00.Enquire
XPD0061-sensor electronics moduleUsage: Promag 10. Consists of: ISEM (sensor electronic module) V316-00.Enquire
XPD0062-sensor electronics moduleUsage: Promag 10. Consists of: ISEM (sensor electronic module) V313-00.Enquire
XPD0063-sensor electronics moduleUsage: Promag 10. Consists of: ISEM (sensor electronic module) V313-00.Enquire
XPD0098-ISEM, standard, IO-Link, Promag 10, nExUsage: Promag 10. Consists of: ISEM (sensor electronic module) V316-00.Enquire
XPD0099-ISEM, enhanced, IO-Link, Promag 10, nExUsage: Promag 10. Consists of: ISEM (sensor electronic module) V313-00.Enquire
XPD0076-Electronic insert HART, 24VDC, nEx, polycarbonate, 10Electronic module E400. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O moduleEnquire
XPD0077-electronic plug-in moduleElectronic module E402. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O moduleEnquire
XPD0078-Power supply module Modbus, 24VDC, nEx, Polycarb., 10Electronic module E406. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O moduleEnquire
XPD0079-Modbus electronic module, 100-230VAC, nEx, polycarbonate, 10Electronic module E409. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O moduleEnquire
XPD0080-HART electronic module, 24 VDC, nEx, Alu, 10Electronic module E401. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O moduleEnquire
XPD0081-Power module, output moduleElectronic module E403. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O moduleEnquire
XPD0082-Power module, output moduleElectronic module E408. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O moduleEnquire
XPD0084-Power module, output moduleElectronic module E411. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O moduleEnquire
XPD0096-IO-Link, nEx, polycarbonate, 10Electronic module E415. Usage: Promag 10, Promass 10. Consists of: Module cartridge, main electronic mod., connection board.Enquire
XPD0097-IO-Link, nEx, alu, 10Electronic module E416. Usage: Promag 10, Promass 10. Consists of: Module cartridge, main electronic mod., connection board.Enquire
XPD0087-Display moduleUsage: Promag 10, Promass 10. Consists of: Display module A400.Enquire
XPD0088-Display moduleUsage: Promag 10, Promass 10. Consists of: Display module A401.Enquire
XPD0089-Display moduleUsage: Promag 10, Promass 10. Consists of: Display module A401.Enquire
71505739Memory moduleElectronic storage module unprogrammed Usage: Promag 10. Consists of: S+T-DAT.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measurement principle video

Click to play

Source: Endress+Hauserpublic information from the website

4 models · click to collapse
Proline Promag H 10(48 条)→

数据摘自 Endress+Hauser 操作手册,含状态信号、可能原因与维修指导。

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Electromagnetic flow meter — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was volumetric flow of conductive liquids.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing liner and electrode pairing by conductivity, solids and abrasion.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing liner and electrode pairing by conductivity, solids and abrasion, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no obstruction, so pressure loss is minimal and upkeep low, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Electromagnetic flow meter — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Electromagnetic flow meter, focusing on volumetric flow of conductive liquids.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Electromagnetic flow meter specification must therefore cover choosing liner and electrode pairing by conductivity, solids and abrasion.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing liner and electrode pairing by conductivity, solids and abrasion, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no obstruction, so pressure loss is minimal and upkeep low, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Electromagnetic flow meter — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Electromagnetic flow meter; the focus is volumetric flow of conductive liquids.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing liner and electrode pairing by conductivity, solids and abrasion.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing liner and electrode pairing by conductivity, solids and abrasion, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no obstruction, so pressure loss is minimal and upkeep low, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Electromagnetic flow meter — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Electromagnetic flow meter and the core task is volumetric flow of conductive liquids.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Electromagnetic flow meter cannot be specified generically — it calls for choosing liner and electrode pairing by conductivity, solids and abrasion.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing liner and electrode pairing by conductivity, solids and abrasion, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no obstruction, so pressure loss is minimal and upkeep low.