Order Code:5L4C50-AALHA0AQD211A+AK
Name:Promag L 400, 5L4C50, DN50 2"
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | AA | Non-hazardous area |
| 015 | Power Supply | L | 100-240VAC/24VAC/DC |
| 020 | Output; Input | H | 4-20mA HART, pulse/freq., switch output |
| 040 | Housing | A | Compact, alu, coated |
| 045 | Cable, Remote Version | 0 | Not used |
| 050 | Electrical Connection | A | Gland M20 |
| 060 | Liner | Q | PTFE 90oC |
| 070 | Process Connection | D21 | PN10, carbon steel, lap joint flange - stamped plate EN1092-1 |
| 075 | Electrodes | 1 | Alloy C22 |
| 080 | Calibration Flow | A | 0.5% |
| 500 | Operation Language Display | AK | Chinese simplified |
Configuration Explained
This is a 5L4C electromagnetic flowmeter, size DN50, non-hazardous area, 100-240V AC or 24V DC supply, 4-20mA HART plus pulse, frequency and switch output, compact coated aluminium housing with M20 entry, corrosion-resistant PTFE liner, PN10 carbon steel loose flange to EN1092-1, Alloy C22 electrodes that withstand chloride ions and oxidising media, 0.5% calibration, display in Chinese, suitable for flow metering in chemical and wastewater applications.