Technical Data
CompareLiquids
| Measuring Principle | Electromagnetic |
| Product headline | High-temperature flowmeter for process applications as remote version with up to 4 I/Os. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures. |
| Sensor features | Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA. |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
| Nominal diameter range | DN 15 to 600 (½ to 24") |
| Wetted materials | Liner: PFA; PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium; Duplex 1.4462 (UNS S31803) |
| Measured variables | Volume flow, conductivity, mass flow |
| Max. measurement error | Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec |
| Measuring range | 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min) |
| Max. process pressure | PN 40, Class 300, 20K |
| Medium temperature range | Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F) |
| Ambient temperature range | Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | DN 15 to 300 (½ to 12"): AlSi10Mg, coated DN 350 to 600 (14 to 24"): Carbon steel with protective varnish Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4409 (CF3M) similar to 316L |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
| Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Transmitter remote version: IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Modbus TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | ACS, NSF 61, WRAS |
The Promag P sensor is designed specifically for measuring high-temperature, corrosive media in chemical and process applications. Combined with the innovative remote transmitter, Promag P 500 offers maximum installation flexibility and maximum operational safety even under harsh operating conditions. Heartbeat Technology ensures compliance at all times and guarantees process safety.
Advantages
Wide range of applications: various welded wetted-part materials available
Energy-saving flow measurement: no pressure loss thanks to the absence of flow restrictors
Maintenance-free: no moving parts
Complete access to process and diagnostic information: a wide range of user-configurable input/output combinations and fieldbuses
Reduced complexity and variety: user-configurable input/output functions
Integrated verification: built-in Heartbeat Technology
Application areas
Bidirectional measuring principle unaffected by pressure, density, temperature and viscosity
Dedicated flowmeter for measuring high-temperature, corrosive media in chemical and process applications
Instrument features
Nominal diameter: max. DN 600 (24")
All common explosion protection (Ex) approvals
PTFE or PFA liner
Remote version with up to 4 inputs/outputs
Backlit display, touch control and WLAN access
Sensor and transmitter connected via standard cable
Spare Parts & Accessories 71
71 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| XPD0027- | 300/500 ISEM electronic plug-in moduleUsage: Promag 300/500 | Enquire |
| XPD0037- | I/O moduleUsage: Proline 300/500 | Enquire |
| XPD0038- | I/O moduleUsage: Proline 300/500 | Enquire |
| XPD0038- | I/O moduleUsage: Proline 300/500 | Enquire |
| XPD0031- | Display moduleUsage: Proline 300/500, DKX001. | Enquire |
| 71323007 | Power supply assemblyUsage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment. | Details |
| 71323008 | Power supply assemblyUsage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment. | Details |
| 71323009 | Power supply assemblyUsage: Promag/Promass/Prosonic Flow/ t-mass/Teqwave MW 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment. | Details |
| 71323013 | Main electronics connection board assembly, non-explosion-proof, 500 digitalUsage: Promag/Promass/Prosonic Flow/ t-mass/Teqwave MW 500 digital, transmitter housing, electronic compartment. | Details |
| 71323014 | Main electronic connection board assembly, explosion-proof, Promag 500 digitalUsage: Promag/Prosonic Flow 500 digital, transmitter housing, electronic compartment. | Details |
| 71323015 | ISEM Connection Board Assembly, Explosion-proof, 500 DigitalUsage: Promag/Promass/t-mass/ Teqwave MW 500 digital, sensor connection housing. | Details |
| 71185788 | T-DAT module | Details |
| 71323010 | Module housing, 300/500, ExUsage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board. | Details |
| 71323005 | ribbon cable assemblyUsage: Promag/Promass 300/500, t-mass/Teqwave MW 300, transmitter housing. | Details |
| 71323006 | ribbon cable assemblyUsage: Promag/Promass/t-mass/ Teqwave MW 500 digital, sensor connection housing. | Details |
| 71323075 | Terminal Block AssemblyUsage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus, Profinet APL, Modbus TCP APL. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol. | Details |
| 71323076 | Terminal Block AssemblyUsage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: 2x connection terminal 2-Pol. | Details |
| 71327819 | Terminal Block AssemblyUsage: transmitter housing Alu/cast, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol. | Details |
| 71323077 | Terminal Block AssemblyUsage: transmitter housing Alu/polycarbonate, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus, Profinet APL, Modbus TCP APL. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol. | Details |
| 71323078 | Terminal Block AssemblyUsage: transmitter housing Alu/polycarbonate, connection compartment. Option B = EtherNet, PROFINET. Consists of: 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol. | Details |
Configurator / Comparison
Accessories / Spare parts
Source:Endress+Hauserpublic information from the website
Measuring principle video
Click to playDiagnostic codes
Proline Promag P 500(79 条)→数据摘自 Endress+Hauser 操作手册,含状态信号、可能原因与维修指导。
Case Studies
Municipal Wastewater Treatment · Electromagnetic flow meter — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was volumetric flow of conductive liquids.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing liner and electrode pairing by conductivity, solids and abrasion.
What We Did
We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing liner and electrode pairing by conductivity, solids and abrasion, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — no obstruction, so pressure loss is minimal and upkeep low, with routine maintenance falling noticeably.
Food & Beverage · Electromagnetic flow meter — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Electromagnetic flow meter, focusing on volumetric flow of conductive liquids.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Electromagnetic flow meter specification must therefore cover choosing liner and electrode pairing by conductivity, solids and abrasion.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing liner and electrode pairing by conductivity, solids and abrasion, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — no obstruction, so pressure loss is minimal and upkeep low, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · Electromagnetic flow meter — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Electromagnetic flow meter; the focus is volumetric flow of conductive liquids.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing liner and electrode pairing by conductivity, solids and abrasion.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing liner and electrode pairing by conductivity, solids and abrasion, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means no obstruction, so pressure loss is minimal and upkeep low, which cut the workload on the site maintenance team.
Power & Energy · Electromagnetic flow meter — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Electromagnetic flow meter and the core task is volumetric flow of conductive liquids.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Electromagnetic flow meter cannot be specified generically — it calls for choosing liner and electrode pairing by conductivity, solids and abrasion.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing liner and electrode pairing by conductivity, solids and abrasion, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is no obstruction, so pressure loss is minimal and upkeep low.
Related Products
Endress+HauserElectromagnetic flowmeter
Endress+HauserElectromagnetic flowmeter 10
Endress+HauserElectromagnetic flowmeter
Endress+HauserElectromagnetic flowmeter
Endress+HauserBattery-powered electromagnetic flowmeter
Endress+HauserMAGPHANT
Endress+HauserElectromagnetic flowmeter
Endress+Hauser