Product family: t-mass 65I
t-mass 65I
Endress+Hauser 65I-40AA0AD1AAAABA
Belongs to 65I t-mass(65I)
t-mass 65I;Insertion Tube Length 435 mm 17";Material Insertion Tube/Sensor Stainl. steel; Stainl. steel;Process Connection 1" MNPT, thread ANSI, compression fitting, Stainl. steel;Seal PEEK, -40...+13

Order Code:65I-40AA0AD1AAAABA

Name:t-mass 65I

Configuration

CodeNameOrderSpecification
005Insertion Tube Length40435 mm 17"
010Material Insertion Tube; SensorAStainl. steel; Stainl. steel
020Process ConnectionA1" MNPT, thread ANSI, compression fitting, Stainl. steel
030Seal0PEEK, -40...+130oC/-40...+266oF
040Surface cleaningABasic version
050CalibrationDFactory calibration
060Additional Test, certificate1Basic version
070ApprovalANon-hazardous area
080HousingACompact Alu, IP67 NEMA4X
090Cable EntryAGland M20 (EEx d > thread M20)
100Display; OperationA85-260VAC, 2-line + push buttons
110Adjustment; Software FeatureBDefault Gas (Air 1.013bar a/14.692psi a)
120Output, InputA4-20mA HART + frequency

Configuration Explained

This is a 65I insertion thermal mass flowmeter, pipe length 435 mm, for 17-inch pipe, for non-hazardous areas, the 65I is discontinued, replacement model 6I3B or 6I5B, insertion probe easy to install and remove, measuring rod and sensor in stainless steel, 1" MNPT threaded compression fitting, PEEK seal rated -40 to 130 °C, 85 to 260 VAC supply, aluminium housing IP67, two-line display with keys, 4-20 mA HART plus frequency output, suitable for boiler forced draught and exhaust duct monitoring.