Technical Data
CompareLiquids
| Measuring Principle | Thermal |
| Product headline | The flowmeter for reliable and easy monitoring of liquids. Dedicated to the monitoring of conductive and non‐conductive liquids. |
| Sensor features | High process safety – high repeatability and linearity due to integrated temperature compensation. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement. Insertion version for nominal diameter DN 40 to 1000 (1½ to 40"). Sensor in standard or hygienic version. |
| Transmitter features | Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4‐20 mA HART, pulse/frequency/switch output. |
| Nominal diameter range | DN 40 to 1000 (1½ to 40") |
| Wetted materials | Transducer: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Insertion tube: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: ‐ Compression fitting: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022) ‐ Threadolet: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022) ‐ Clamping ferrule: PEEK 450G; 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022) ‐ Tri‐Clamp; DN40 DIN 11851, DN50 DIN 11851; DN40 DIN 11864‐1A, DN50 DIN 11864‐1A: 1.4404 (316L) |
| Measured variables | Mass flow, temperature, volume flow |
| Max. measurement error | Flow: ±5 % o.f.s. |
| Measuring range | 226 to 14 100 000 l/h (60 to 3 730 000 gal/h) (under reference conditions) |
| Max. process pressure | PN 40 |
| Medium temperature range | –20 to +100 °C (–4 to +212 °F) |
| Ambient temperature range | –40 to +60 °C (–40 to +140 °F) |
| Transmitter housing material | AlSi10Mg, coated |
| Degree of protection | IP66/67, type 4X enclosure |
| Display/Operation | 4‐line display with push buttons Configuration via local display and operating tools possible |
| Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital communication | HART |
| Power supply | DC 18 to 30 V |
| Hazardous area approvals | ATEX, IECEx, cCSAus, EAC |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR Hygienic approvals: EHEDG, 3-A |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Pressure approvals and certificates | CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | Sanitary approval: 3-A, EHEDG |
Product Overview
The t-mass T 150 is the first Endress+Hauser thermal mass flowmeter for liquid measurement. The t-mass T 150 is mainly used for measurement in water; when the flowmeter measures the conductivity of a liquid independently, it can also be used for monitoring and trend monitoring of various conductive and non-conductive liquids. User-specific substances can be stored on the display and transferred from one device to another via the display.
-
Advantages
-
Specially designed for monitoring conductive and non-conductive liquids
-
High process safety: built-in temperature compensation, high repeatability and linearity
-
Economical measurement: easy installation, negligible pressure loss, maintenance-free
-
Reliable flow trend: multivariable measurement
-
Fast and effective commissioning: guided operating menu
-
High plant adaptability: self-diagnostics and error monitoring
-
Automatic data recovery for easy maintenance
-
Areas of application
-
The measuring principle has a highly operable measuring range and directly measures mass flow
-
Professional measurement of conductive and non-conductive liquid flow
-
Device features
-
Insertion type suitable for pipes with nominal diameters from DN 40 to 1000 (1 1/2 to 40")
-
Standard sensor or hygienic sensor
-
SIP-resistant, temperature up to 130 °C (266 °F)
-
Compact version with DC 24 V power supply
-
4-20 mA HART, pulse/frequency/switch output
-
Compact and robust transmitter
Spare Parts & Accessories 28
28 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| XPD0022- | Electronic plug-in module T 150Main electronic module | Enquire |
| 71109658 | Display module kit, SD02, push buttonsFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Usage: Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover. | Details |
| XPD0024- | Display moduleFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover. | Enquire |
| 71158893 | Terminal block x10, 8-pin, t-mass 150 | Details |
| 71158894 | aluminum cover assembly, window glass, gasketUsage: t-mass 150. Material: Cover Aluminium, coated. O-Ring 88,50x3,53 NBR,PTFE coated. | Details |
| 71158895 | aluminum cover assembly, blind cover, gasketUsage: t-mass 150. Material: Cover Aluminium, coated. O-Ring 88,50x3,53 NBR,PTFE coated. | Details |
| 50103658 | cable gland | Details |
| 50098036 | Explosion-proof cable glandKit 10 cable glands M20x1.5 Ex | Details |
| 50098041 | adapterKit 10 extension M20x1.5/G 1/2" | Details |
| 71115505 | M20x1.5/G 1/2" adapter | Details |
| 50098042 | adapterKit 10 extension M20x1.5/NPT 1/2" | Details |
| 71115509 | M20x1.5/NPT1/2" adapter | Details |
| 71240315 | socketUsage: t-mass T 150. | Details |
| 71240316 | adapterUsage: t-mass T 150. | Details |
| 71158896 | Housing gasket assembly, t-mass 150Consists of: O-Ring 88,50x3,53 NBR, PTFE coated, cover electronic compartment. O-Ring 36,10x3,53 HNBR, housing/sensor. | Details |
| 71158897 | Housing assembly, t-mass 150Consists of: Filter plug, Brass Nickel. Pressure compensation filter, PTFE. Hexagon socket set screw M8x12 A2. | Details |
| 71158898 | Washer AssemblyConsists of: Gasket ring 35,0/26,7x2,0, HNBR, 316. | Details |
| 71158900 | Washer AssemblyConsists of: Gasket ring 35,0/26,7x2,0, EPDM, 316. | Details |
| 71240321 | Safety chain, T-mass T150Usage: For pressure >= 4,5 bar (65,27 psi) and PEEK-ferrule. | Details |
| 71240320 | sunshade coverConsists of: Weather protective cover, installation material. | Details |
Configurator / Comparison
Source:Endress+Hauserwebsite public information
Diagnostic codes
Proline t-mass T 150(44 条)→数据摘自 Endress+Hauser 操作手册,含状态信号、可能原因与维修指导。
Case Studies
Municipal Wastewater Treatment · Thermal Gas Mass Flow Meters — Application Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is Thermal Gas Mass Flow Meters; the focus is mass flow of air and fuel gases.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing insertion or in-line type by gas composition, temperature and dust.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing insertion or in-line type by gas composition, temperature and dust, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means direct mass output, making combustion ratios more precise, which cut the workload on the site maintenance team.
Food & Beverage · Thermal Gas Mass Flow Meters — Application Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on Thermal Gas Mass Flow Meters and the core task is mass flow of air and fuel gases.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So Thermal Gas Mass Flow Meters cannot be specified generically — it calls for choosing insertion or in-line type by gas composition, temperature and dust.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing insertion or in-line type by gas composition, temperature and dust, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is direct mass output, making combustion ratios more precise.
Chemical & Pharmaceutical · Thermal Gas Mass Flow Meters — Application Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted Thermal Gas Mass Flow Meters properly configured on the existing plant, with the aim of mass flow of air and fuel gases.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the Thermal Gas Mass Flow Meters configuration has to involve choosing insertion or in-line type by gas composition, temperature and dust.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing insertion or in-line type by gas composition, temperature and dust, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is direct mass output, making combustion ratios more precise, and the readings are now used for process tuning.
Power & Energy · Thermal Gas Mass Flow Meters — Application Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was mass flow of air and fuel gases.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing insertion or in-line type by gas composition, temperature and dust.
What We Did
We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing insertion or in-line type by gas composition, temperature and dust, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — direct mass output, making combustion ratios more precise, with routine maintenance falling noticeably.
Related Products
Endress+HauserThermal gas mass flowmeter
Endress+Hausert-mass 65I
Endress+HauserFlowphant T DTT31
Endress+HauserThermal mass flowmeter
Endress+HauserThermal mass flowmeter
Endress+HauserThermal mass flowmeter
Endress+HauserThermal mass flowmeter
Endress+Hauser