涡街流量计
Technical Data
CompareGas
| Measuring Principle | |
| Product headline | std_productprofile_product_usp_8119_1511861002. std_productprofile_product_usp2_38907_1511797452. For all basic applications and for 1-to-1 replacement of orifice plates. |
| Sensor features | Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. std_productprofile_product_benefits_8115. Face-to-face length of 65 mm (2.56 in). No flanges. Low weight. |
| Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). |
| Nominal diameter range | DN 15 to 150 (½ to 6") |
| Wetted materials | Measuring tube: 1.4408 (C3FM) DSC sensor: 1.4435 (316/316L) |
| Measured variables | Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature |
| Max. measurement error | Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam, gas): ±1.7 % |
| Measuring range | Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) |
| Max. process pressure | PN 40, Class 300, 20K |
| Medium temperature range | Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F) High/low temperature (on request): –200 to +450 °C (–328 to +842 °F) |
| Ambient temperature range | Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F) |
| Sensor housing material | Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M) |
| Transmitter housing material | AlSi10Mg, coated; 1.4404 (316L) |
| Degree of protection | Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
| Outputs | 4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive) |
| Inputs | 4‐20 mA (passive) |
| Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Power supply | DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output) |
| Hazardous area approvals | ATEX, IECEx, cCSAus |
| Other approvals and certificates | |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI (on request) |
Liquids
| Measuring Principle | |
| Product headline | std_productprofile_product_usp_8119_1511861002. std_productprofile_product_usp2_38907_1511797452. For all basic applications and for 1-to-1 replacement of orifice plates. |
| Sensor features | Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. std_productprofile_product_benefits_8115. Face-to-face length of 65 mm (2.56 in). No flanges. Low weight. |
| Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). |
| Nominal diameter range | DN 15 to 150 (½ to 6") |
| Wetted materials | Measuring tube: 1.4408 (C3FM) DSC sensor: 1.4435 (316/316L) |
| Measured variables | Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature |
| Max. measurement error | Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam, gas): ±1.7 % |
| Measuring range | Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) |
| Max. process pressure | PN 40, Class 300, 20K |
| Medium temperature range | Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F) High/low temperature (on request): –200 to +450 °C (–328 to +842 °F) |
| Ambient temperature range | Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F) |
| Sensor housing material | Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M) |
| Transmitter housing material | AlSi10Mg, coated; 1.4404 (316L) |
| Degree of protection | Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
| Outputs | 4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive) |
| Inputs | Current input 4‐20 mA (passive) |
| Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Power supply | DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, EAC |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI (on request) |
Steam
| Measuring Principle | |
| Product headline | std_productprofile_product_usp_8119_1511861002. std_productprofile_product_usp2_38907_1511797452. For all basic applications and for 1-to-1 replacement of orifice plates. |
| Sensor features | Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. std_productprofile_product_benefits_8115. Face-to-face length of 65 mm (2.56 in). No flanges. Low weight. |
| Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). |
| Nominal diameter range | DN 15 to 150 (½ to 6") |
| Wetted materials | Measuring tube: 1.4408 (C3FM) DSC sensor: 1.4435 (316/316L) |
| Measured variables | Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature |
| Max. measurement error | Volume flow (liquid): ±0.75 % Volume flow (steam,, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam,, gas): ±1.7 % |
| Measuring range | Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) |
| Max. process pressure | PN 40, Class 300, 20K |
| Medium temperature range | Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F) High/low temperature (on request): –200 to +450 °C (–328 to +842 °F) |
| Ambient temperature range | Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F) |
| Sensor housing material | Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M) |
| Transmitter housing material | AlSi10Mg, coated; 1.4404 (316L) |
| Degree of protection | Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
| Outputs | 4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive) |
| Inputs | 4‐20 mA (passive) |
| Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Power supply | DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, EAC |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | NACE MR0175/MR0103, PMI (on request) 3.1 material |
The Prowirl D sensor is installed directly between two flanges; it is therefore used as an auxiliary function device in auxiliary process sections at very low cost. The Prowirl D 200 is a genuine two-wire loop-powered flowmeter that is economical to use and can be seamlessly integrated into existing systems, with maximum operational safety in hazardous areas. Heartbeat Technology always ensures process safety.
Advantages
Built-in temperature measurement for mass flow/energy flow measurement of saturated steam
Easy installation: sensor with centering ring
High stability: proven robust device unaffected by vibration, temperature shock and water hammer
High long-term stability: drift-free, robust capacitive sensor
Convenient wiring: device with separate connection compartment
Safe operation: backlit display with touch keys, operable without opening the device
Self-verification: Heartbeat Technology
Areas of application
The measuring principle is particularly suitable for wet steam/saturated steam/superheated steam, gases and liquids (including low-temperature media)
Suitable for all basic applications and for 1:1 orifice plate replacement
Device features
Face-to-face length of 65 mm (2.56 in)
Without flange
Light weight
Display unit with data transfer function
Robust dual-compartment housing
Plant safety: multiple international approvals (SIL, explosion protection)
E+H Product Configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products to compare in the boxes below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserwebsite public information
Related Models
| Model | Name |
|---|---|
| 7D2B80-AABCCA1D2SKABLA | 7D2B80-AABCCA1D2SKABLA |
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Vortex Flow Meter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Vortex Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Vortex Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Vortex Flow Meter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Vortex Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Vortex Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Vortex Flow Meter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Vortex Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Vortex Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Vortex Flow Meter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Vortex Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Vortex Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.