Vortex flowmeter
Configurable Models 20 models
Multifunctional flowmeter with highest measurement accuracy, featuring wet steam detection

The Prowirl F multivariable flowmeter can perform online wet steam measurement. Installed in auxiliary process sections, the flowmeter is designed specifically for steam applications and offers the highest measurement accuracy for gases and liquids. The Prowirl F 200 is a true two-wire loop-powered flowmeter that is economical to use and can be seamlessly integrated into existing systems. It offers maximum operational safety in hazardous areas. Heartbeat Technology always ensures process safety.

Advantages
Convenient energy management: integrated temperature and pressure measurement for steam and gases
Space-saving compact design: optional upstream straight run compensation
Measuring accuracy remains constant even at Reynolds numbers as low as Re 10 000: the vortex flowmeter body has high linearity
High long-term stability: drift-free, robust capacitive sensor
Convenient wiring: separate connection compartment
Safe operation: backlit display with touch key operation, no need to open the instrument during operation
Self-verification: Heartbeat Technology

Application areas
The measuring principle is particularly suitable for wet steam/saturated steam/superheated steam, gases and liquids (and low-temperature media)
Wide range of applications; optimized specifically for steam applications
Instrument features
Applicable nominal diameter range for wet steam measurement: DN 25...300 (1...12")
Flexible pressure sensor installation
Industrial condensate line design compliant with pressure measurement requirements
Display unit with data transmission function
Robust dual-compartment housing
Plant safety: numerous international approvals (SIL, explosion protection)
 

 

Spare Parts & Accessories 74

74 spare parts · click to collapse
Order codeDescription
XPD0043-Electronic module Prowirl 200 Index CMain electronic moduleEnquire
71108602I/O moduleNon-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details
XPD0015-I/O module, 2-wire, 4-20mA, HART, ExNon-Ex, Ex. 1x current output HART.Enquire
XPD0016-I/O module, 2-wire, 4-20mA, HART, PFS, ExNon-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.Enquire
XPD0018-I/O moduleNon-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output. 1x current input.Enquire
XPD0093-I/O module 2-wire, PROFINET w. Ethernet-APL/SPEnquire
XPD0094-I/O, 2-wire, Modbus TCP or Ethernet-APL/SPEEnquire
71164940I/O moduleNon-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS=switch output. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass 200, Prowirl 200, Promag 200.Details
71222996Preamplifier ModuleDetails
71128617Overvoltage protector4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.Details
71128619Overvoltage protector4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.Details
XPD0024-Display moduleFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.Enquire
XPD0025-Display moduleFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.Enquire
71197334Transmitter FHX50Consists of: electronics, ribbon cable. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass200, Prowirl 200, Promag 200, Prosonic Flow 200.Details
71296840Plug connector M12, VATo connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.Details
71206552CableConnection cable, shielded. Usage: FHX50, FHX50B.Details
71206554CableConnection cable, shielded. Usage: FHX50, FHX50B.Details
71206555CableConnection cable, shielded. Usage: FHX50, FHX50B.Details
71206556CableConnection cable, shielded. Usage: FHX50, FHX50B.Details
71222998Cable for connecting the preamplifier boardDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

   

Measuring principle video

Click to play

Source:Endress+Hauserpublic information from the website

749 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Vortex flowmeter — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on Vortex flowmeter and the core task is flow of steam, gases and low-viscosity liquids.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So Vortex flowmeter cannot be specified generically — it calls for sizing bore and bluff body by minimum flow, vibration and temperature.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves sizing bore and bluff body by minimum flow, vibration and temperature, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is no moving parts, so steam metering stays stable over years.

Food & Beverage

Food & Beverage · Vortex flowmeter — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted Vortex flowmeter properly configured on the existing plant, with the aim of flow of steam, gases and low-viscosity liquids.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the Vortex flowmeter configuration has to involve sizing bore and bluff body by minimum flow, vibration and temperature.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant sizing bore and bluff body by minimum flow, vibration and temperature, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is no moving parts, so steam metering stays stable over years, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Vortex flowmeter — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was flow of steam, gases and low-viscosity liquids.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means sizing bore and bluff body by minimum flow, vibration and temperature.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around sizing bore and bluff body by minimum flow, vibration and temperature, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — no moving parts, so steam metering stays stable over years, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · Vortex flowmeter — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from Vortex flowmeter, focusing on flow of steam, gases and low-viscosity liquids.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The Vortex flowmeter specification must therefore cover sizing bore and bluff body by minimum flow, vibration and temperature.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on sizing bore and bluff body by minimum flow, vibration and temperature, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — no moving parts, so steam metering stays stable over years, with confidence in this measuring point improving markedly.