Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

73F Vortex flowmeter

73F Vortex flowmeter
Vortex flowmeter
The Prowirl 73F is designed for the universal measurement of the volume flow of gases, steam and liquids. The proven and patented capacitive DSC sensor ensures high precision measured values even under the toughest process conditions. Prowirl 73F offers genuine, industry-compliant two-wire technology for seamless integration into existing infrastructures and control systems. In addition it provides an integrated temp. sensor and flow computer for mass and energy of steam, gases and liquids.
Compare

Gas

Measuring Principle Vortex
Product headline Volume flow meter for measurement of standard liquid / gas /steam applications
Flow, temperature probe and flow computer in one device
Nominal diameter range DN15...300
1/2"...12"
Max. measurement error Volume flow: +-1.0%
Measuring range 3...19'700m3/h
Max. process pressure PN16...40
CL 150...300
JIS10...20K
Medium temperature range -200...+400°C
(-328...+752°F)
up to +450°C / +842°F on request
Degree of protection IP67
NEMA 4x
Display/Operation Two line liquid
Crystal display
Push nbuttons
Quick Setup
Outputs 4...20mA
Pulse
Frequency
Status
PFM
Inputs pressure input using PROFIBUS PA,
HART or FOUNDATION Fieldbus
Digital communication HART
PROFIBUS PA
FOUNDATION Fieldbus
Hazardous area approvals ATEX
FM
CSA
TIIS
NEPSI/IEC on request

Liquids

Measuring Principle Vortex
Product headline Volume flow meter for measurement of standard liquid / gas /steam applications
Flow, temperature probe and flow computer in one device
Nominal diameter range DN15...300
1/2"...12"
Max. measurement error +/-0.75% vol. fl.typically +/- 1% mass fl.
Measuring range 0.16...2'360m3/h
Max. process pressure PN16...40
CL 150...300
JIS10...20K
Medium temperature range -200...+400°C
(-330 to +750°F)
up to +450°C / 842°F on request)
Degree of protection IP67
NEMA 4x
Display/Operation Two line liquid
Crystal display
Push nbuttons
Quick Setup
Outputs 4...20mA
Pulse
Frequency
Status
PFM
Inputs pressure input using PROFIBUS PA, HART
or FOUNDATION Fieldbus
Digital communication HART
PROFIBUS PA
FOUNDATION Fieldbus
Hazardous area approvals ATEX
FM
CSA
TIIS
NEPSI/IEC on request

Steam

Measuring Principle Vortex
Product headline Volume flow meter for measurement of standard liquid / gas /steam applications
Flow, temperature probe and flow computer in one device
Nominal diameter range DN15...300
1/2"...12"
Max. measurement error Volume flow: +/-1.0%
Mass flow: +/-1.7%-2.3% (saturated steam)
Measuring range 0.19...5'210m3/h
Max. process pressure PN16...40
CL 150...300
JIS10...20K
Medium temperature range -200...+400°C
(-328...+752°F)
up to +450°C / 842°F on request
Degree of protection IP67
NEMA 4x
Display/Operation Two line liquid
Crystal display
Push nbuttons
Quick Setup
Outputs 4...20mA
Pulse
Frequency
Status
PFM
Inputs pressure input using PROFIBUS PA, HART
or FOUNDATION Fieldbus for superheated steam
temperature input using HART for delta heat
Digital communication HART
PROFIBUS PA
FOUNDATION Fieldbus
Hazardous area approvals ATEX
FM
CSA
TIIS
NEPSI/IEC on request

Universal volumetric flow measurement of gases, steam and liquids. Thanks to the built-in temperature measurement and the reading of an external pressure value (Prowirl 73), the mass flow of steam, water (in accordance with the IAPWS-IF97 ASME standard), natural gas (in accordance with the AGA NX-19 / AGA8-DC92 detailed method / AGA8 Gross Method 1 / SGERG-88 standard), compressed air, other gases and liquids can be calculated.

Benefits

  • The Prowirl sensor family has passed more than 200,000 tests and verifications and offers the following advantages:

  • High vibration resistance, resistance to temperature shocks, suitable for contaminated fluids, resistance to water hammer

  • Maintenance-free, no moving parts, no zero-point drift (“lifetime” calibration)

  • Software-based initial setup saves time and operating costs

  • Extended applications:

  • A single instrument measures the mass flow of saturated steam or liquids

  • Built-in flow computer calculates the mass flow based on the measured volumetric flow and temperature values

  • External pressure input for measuring superheated steam and gases

  • External temperature input for heat exchange measurement

Application

  • Fluid temperature range: –200 ... +400 °C (–328 ... +752 °F)

  • Pressure ratings up to PN 250 / Class 1500 

  • The sensor features an integrated reducer, with selectable one-stage reduction (type R) or two-stage reduction (type S)

  • Optional dual-sensor flowmeter (Dualsens type) for redundant measurement, with two sensors and two sets of electronics

  • Hazardous area approvals:

  • ATEX, FM, CSA, TIIS, NEPSI, IEC

  • HART, PROFIBUS PA, FOUNDATION Fieldbus (FF)

  • Pressure Equipment Directive (PED), SIL-2 safety

Spare Parts & Accessories 46

46 spare parts · click to collapse
Order codeDescription
50106027*** Amplifier BoardDetails
71109321*** Amplifier BoardDetails
50103476*** Intrinsically Safe Current Output ModuleKit I/O-board PW 72/73 HART ExiDetails
50103477*** Intrinsically Safe Current/Pulse Output ModuleKit I/O-board PW 72/73 HART/pulse ExiDetails
50103478Intrinsically Safe PA Input/Output BoardKit I/O-board PW72/73 PROFIBUS PA ExiDetails
50107084*** Intrinsically Safe FF Input/Output BoardKit I/O-board PW72/73Found.Fieldbus ExiDetails
50106382I/O-board kit PW 72/73 HART ExdKit I/O-board PW 72/73 HART ExdDetails
50106384*** Explosion-proof current/pulse output moduleKit I/O-board PW 72/73 HART/pulse ExdDetails
50106383*** Explosion-proof PA I/O BoardKit I/O-board PW 72/73 PROFIBUS PA ExdDetails
50107085*** Flameproof FF Input/Output BoardKit I/O-board PW72/73Found.Fieldbus ExdDetails
50106385*** Flameproof PA/FF Wiring ModuleKit conn. board PW72/73PROFIB.PA/FF ExdDetails
50103472Display module (HART)Kit display 72/73/92F w. keyboard(HART)Details
71123423Display module (HART)Language:EN+DE+FR+ES+IT+NL+NO+SV+ FI+PT+PL+CS+ZH+JA+RUDetails
50103473Display module (PA/FF)Kit display72/73/92F w/o keyboard(FF/PA)Details
71123425*** Display Module (FF/PA)Language: EN+DE+FR+ES+IT+NL+NO+SV+ FI+PT+PL+CS+ZH+JA+RUDetails
50103474Preamplifier kit PW 72/73Kit preamplifier PW 72/73Details
50103884*** transmitter terminal compartment explosion-proof terminal boardDetails
50103885*** Sensor Terminal Compartment Explosion-proof Terminal BoardDetails
50108141terminal blockKit Terminal Block 72/73/92FDetails
50103526cover with windowKit cover 72/73/92F with windowDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
Diagnostic codes(66 条)→
All documents for this model
12 documents · click to expand
BA

Proline Prowirl 72 HART Operating Instructions, Description of Device Functions English

HART Rev. 1411 124 pages
Preview
BA

Proline Prowirl 73 FOUNDATION Fieldbus Operating Instructions English

FOUNDATION-Fieldbus Rev. 1311 169 pages
Preview
BA

Proline Prowirl 73 PROFIBUS-PA Operating Instructions English

PROFIBUS-PA Rev. 1311 166 pages
Preview
BA

Proline Prowirl 72 HART Operating Instructions, Description of Device Functions English

HART Rev. 1108 136 pages
Preview
BA

Prowirl 73 Operating Instructions English

146 pages
Preview
BA

Prowirl 73 FOUNDATION Fieldbus Operating Manual English

FOUNDATION-Fieldbus 172 pages
Preview
BA

Prowirl 73 PROFIBUS-PA Operating Manual English

PROFIBUS-PA 172 pages
Preview
TI

技术资料 Proline Prowirl 72F, 72W, 73F, 73W Chinese

Rev. 1411 64 pages
Preview
TI

涡街流量测量系统 Chinese

Rev. 0111 64 pages
Preview
TI

Proline Prowirl 72F, 72W, 73F, 73W Technical Information English

Rev. 1411 64 pages
Preview
TI

Proline Prowirl 72F, 72W, 73F, 73W Technical Information (SI units) English

Rev. 1108 62 pages
Preview
TI

Vortex Flow Measuring System for reliable Flow Measurement of Gas, Steam and Liquids. English

24 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Vortex flowmeter — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on Vortex flowmeter and the core task is flow of steam, gases and low-viscosity liquids.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So Vortex flowmeter cannot be specified generically — it calls for sizing bore and bluff body by minimum flow, vibration and temperature.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves sizing bore and bluff body by minimum flow, vibration and temperature, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is no moving parts, so steam metering stays stable over years.

Food & Beverage

Food & Beverage · Vortex flowmeter — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted Vortex flowmeter properly configured on the existing plant, with the aim of flow of steam, gases and low-viscosity liquids.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the Vortex flowmeter configuration has to involve sizing bore and bluff body by minimum flow, vibration and temperature.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant sizing bore and bluff body by minimum flow, vibration and temperature, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is no moving parts, so steam metering stays stable over years, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Vortex flowmeter — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was flow of steam, gases and low-viscosity liquids.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means sizing bore and bluff body by minimum flow, vibration and temperature.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around sizing bore and bluff body by minimum flow, vibration and temperature, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — no moving parts, so steam metering stays stable over years, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · Vortex flowmeter — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from Vortex flowmeter, focusing on flow of steam, gases and low-viscosity liquids.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The Vortex flowmeter specification must therefore cover sizing bore and bluff body by minimum flow, vibration and temperature.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on sizing bore and bluff body by minimum flow, vibration and temperature, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — no moving parts, so steam metering stays stable over years, with confidence in this measuring point improving markedly.