Technical Data
CompareGas
| Measuring Principle | Vortex |
| Product headline | Volume flow meter for measurement of standard liquid / gas /steam applications Flow, temperature probe and flow computer in one device |
| Nominal diameter range | DN15...300 1/2"...12" |
| Max. measurement error | Volume flow: +-1.0% |
| Measuring range | 3...19'700m3/h |
| Max. process pressure | PN16...40 CL 150...300 JIS10...20K |
| Medium temperature range | -200...+400°C (-328...+752°F) up to +450°C / +842°F on request |
| Degree of protection | IP67 NEMA 4x |
| Display/Operation | Two line liquid Crystal display Push nbuttons Quick Setup |
| Outputs | 4...20mA Pulse Frequency Status PFM |
| Inputs | pressure input using PROFIBUS PA, HART or FOUNDATION Fieldbus |
| Digital communication | HART PROFIBUS PA FOUNDATION Fieldbus |
| Hazardous area approvals | ATEX FM CSA TIIS NEPSI/IEC on request |
Liquids
| Measuring Principle | Vortex |
| Product headline | Volume flow meter for measurement of standard liquid / gas /steam applications Flow, temperature probe and flow computer in one device |
| Nominal diameter range | DN15...300 1/2"...12" |
| Max. measurement error | +/-0.75% vol. fl.typically +/- 1% mass fl. |
| Measuring range | 0.16...2'360m3/h |
| Max. process pressure | PN16...40 CL 150...300 JIS10...20K |
| Medium temperature range | -200...+400°C (-330 to +750°F) up to +450°C / 842°F on request) |
| Degree of protection | IP67 NEMA 4x |
| Display/Operation | Two line liquid Crystal display Push nbuttons Quick Setup |
| Outputs | 4...20mA Pulse Frequency Status PFM |
| Inputs | pressure input using PROFIBUS PA, HART or FOUNDATION Fieldbus |
| Digital communication | HART PROFIBUS PA FOUNDATION Fieldbus |
| Hazardous area approvals | ATEX FM CSA TIIS NEPSI/IEC on request |
Steam
| Measuring Principle | Vortex |
| Product headline | Volume flow meter for measurement of standard liquid / gas /steam applications Flow, temperature probe and flow computer in one device |
| Nominal diameter range | DN15...300 1/2"...12" |
| Max. measurement error | Volume flow: +/-1.0% Mass flow: +/-1.7%-2.3% (saturated steam) |
| Measuring range | 0.19...5'210m3/h |
| Max. process pressure | PN16...40 CL 150...300 JIS10...20K |
| Medium temperature range | -200...+400°C (-328...+752°F) up to +450°C / 842°F on request |
| Degree of protection | IP67 NEMA 4x |
| Display/Operation | Two line liquid Crystal display Push nbuttons Quick Setup |
| Outputs | 4...20mA Pulse Frequency Status PFM |
| Inputs | pressure input using PROFIBUS PA, HART or FOUNDATION Fieldbus for superheated steam temperature input using HART for delta heat |
| Digital communication | HART PROFIBUS PA FOUNDATION Fieldbus |
| Hazardous area approvals | ATEX FM CSA TIIS NEPSI/IEC on request |
Universal volumetric flow measurement of gases, steam and liquids. Thanks to the built-in temperature measurement and the reading of an external pressure value (Prowirl 73), the mass flow of steam, water (in accordance with the IAPWS-IF97 ASME standard), natural gas (in accordance with the AGA NX-19 / AGA8-DC92 detailed method / AGA8 Gross Method 1 / SGERG-88 standard), compressed air, other gases and liquids can be calculated.
Benefits
-
The Prowirl sensor family has passed more than 200,000 tests and verifications and offers the following advantages:
-
High vibration resistance, resistance to temperature shocks, suitable for contaminated fluids, resistance to water hammer
-
Maintenance-free, no moving parts, no zero-point drift (“lifetime” calibration)
-
Software-based initial setup saves time and operating costs
-
Extended applications:
-
A single instrument measures the mass flow of saturated steam or liquids
-
Built-in flow computer calculates the mass flow based on the measured volumetric flow and temperature values
-
External pressure input for measuring superheated steam and gases
-
External temperature input for heat exchange measurement
Application
-
Fluid temperature range: –200 ... +400 °C (–328 ... +752 °F)
-
Pressure ratings up to PN 250 / Class 1500
-
The sensor features an integrated reducer, with selectable one-stage reduction (type R) or two-stage reduction (type S)
-
Optional dual-sensor flowmeter (Dualsens type) for redundant measurement, with two sensors and two sets of electronics
-
Hazardous area approvals:
-
ATEX, FM, CSA, TIIS, NEPSI, IEC
-
HART, PROFIBUS PA, FOUNDATION Fieldbus (FF)
-
Pressure Equipment Directive (PED), SIL-2 safety
Spare Parts & Accessories 46
46 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 50106027 | *** Amplifier Board | Details |
| 71109321 | *** Amplifier Board | Details |
| 50103476 | *** Intrinsically Safe Current Output ModuleKit I/O-board PW 72/73 HART Exi | Details |
| 50103477 | *** Intrinsically Safe Current/Pulse Output ModuleKit I/O-board PW 72/73 HART/pulse Exi | Details |
| 50103478 | Intrinsically Safe PA Input/Output BoardKit I/O-board PW72/73 PROFIBUS PA Exi | Details |
| 50107084 | *** Intrinsically Safe FF Input/Output BoardKit I/O-board PW72/73Found.Fieldbus Exi | Details |
| 50106382 | I/O-board kit PW 72/73 HART ExdKit I/O-board PW 72/73 HART Exd | Details |
| 50106384 | *** Explosion-proof current/pulse output moduleKit I/O-board PW 72/73 HART/pulse Exd | Details |
| 50106383 | *** Explosion-proof PA I/O BoardKit I/O-board PW 72/73 PROFIBUS PA Exd | Details |
| 50107085 | *** Flameproof FF Input/Output BoardKit I/O-board PW72/73Found.Fieldbus Exd | Details |
| 50106385 | *** Flameproof PA/FF Wiring ModuleKit conn. board PW72/73PROFIB.PA/FF Exd | Details |
| 50103472 | Display module (HART)Kit display 72/73/92F w. keyboard(HART) | Details |
| 71123423 | Display module (HART)Language:EN+DE+FR+ES+IT+NL+NO+SV+ FI+PT+PL+CS+ZH+JA+RU | Details |
| 50103473 | Display module (PA/FF)Kit display72/73/92F w/o keyboard(FF/PA) | Details |
| 71123425 | *** Display Module (FF/PA)Language: EN+DE+FR+ES+IT+NL+NO+SV+ FI+PT+PL+CS+ZH+JA+RU | Details |
| 50103474 | Preamplifier kit PW 72/73Kit preamplifier PW 72/73 | Details |
| 50103884 | *** transmitter terminal compartment explosion-proof terminal board | Details |
| 50103885 | *** Sensor Terminal Compartment Explosion-proof Terminal Board | Details |
| 50108141 | terminal blockKit Terminal Block 72/73/92F | Details |
| 50103526 | cover with windowKit cover 72/73/92F with window | Details |
Configurator / Comparison
12 documents · click to expand
Proline Prowirl 72 HART Operating Instructions, Description of Device Functions English
Proline Prowirl 73 FOUNDATION Fieldbus Operating Instructions English
Proline Prowirl 73 PROFIBUS-PA Operating Instructions English
Proline Prowirl 72 HART Operating Instructions, Description of Device Functions English
Prowirl 73 Operating Instructions English
Prowirl 73 FOUNDATION Fieldbus Operating Manual English
Prowirl 73 PROFIBUS-PA Operating Manual English
技术资料 Proline Prowirl 72F, 72W, 73F, 73W Chinese
涡街流量测量系统 Chinese
Proline Prowirl 72F, 72W, 73F, 73W Technical Information English
Proline Prowirl 72F, 72W, 73F, 73W Technical Information (SI units) English
Vortex Flow Measuring System for reliable Flow Measurement of Gas, Steam and Liquids. English
Product Videos
View allCase Studies
Municipal Wastewater Treatment · Vortex flowmeter — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on Vortex flowmeter and the core task is flow of steam, gases and low-viscosity liquids.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So Vortex flowmeter cannot be specified generically — it calls for sizing bore and bluff body by minimum flow, vibration and temperature.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves sizing bore and bluff body by minimum flow, vibration and temperature, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is no moving parts, so steam metering stays stable over years.
Food & Beverage · Vortex flowmeter — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted Vortex flowmeter properly configured on the existing plant, with the aim of flow of steam, gases and low-viscosity liquids.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the Vortex flowmeter configuration has to involve sizing bore and bluff body by minimum flow, vibration and temperature.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant sizing bore and bluff body by minimum flow, vibration and temperature, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is no moving parts, so steam metering stays stable over years, and the readings are now used for process tuning.
Chemical & Pharmaceutical · Vortex flowmeter — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was flow of steam, gases and low-viscosity liquids.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means sizing bore and bluff body by minimum flow, vibration and temperature.
What We Did
We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around sizing bore and bluff body by minimum flow, vibration and temperature, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — no moving parts, so steam metering stays stable over years, with routine maintenance falling noticeably.
Power & Energy · Vortex flowmeter — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from Vortex flowmeter, focusing on flow of steam, gases and low-viscosity liquids.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The Vortex flowmeter specification must therefore cover sizing bore and bluff body by minimum flow, vibration and temperature.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on sizing bore and bluff body by minimum flow, vibration and temperature, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — no moving parts, so steam metering stays stable over years, with confidence in this measuring point improving markedly.
Related Products
Endress+HauserVortex flowmeter
Endress+HauserVortex flowmeter
Endress+HauserVortex flowmeter
Endress+HauserVortex flowmeter
Endress+HauserVortex flowmeter
Endress+HauserVortex flowmeter
Endress+HauserVortex flowmeter
Endress+Hauser