93C Ultrasonic flowmeter

93C Ultrasonic flowmeter
Ultrasonic flowmeter
The inline ultrasonic flowmeter Prosonic Flow C is based on the Prosonic Flow W insertion sensor. It was designed for the water and wastewater industry. Combined with the Prosonic Flow 93 transmitter with touch control, four-line display and extended functionality, Prosonic Flow 93C offers high accuracy in standard applications.
Compare

Liquids

Measuring Principle
Product headline std_productprofile_product_usp_60153_1581515154.
std_productprofile_product_field_of_application_60154_1581515575.
Sensor features std_productprofile_product_benefits_60155_1581515575. std_productprofile_product_benefits_60156_1581515575. std_productprofile_product_benefits_60157_1581515575.
std_successorproducts_product_differentiating_tech_features_60158_1581515675. std_successorproducts_product_differentiating_tech_features_60159_1581515675. std_successorproducts_product_differentiating_tech_features_60160_1581515675.
Transmitter features std_productprofile_product_benefits_60161_1581516129. std_productprofile_product_benefits_60162_1581516129. std_productprofile_product_benefits_60163_1581516129.
std_successorproducts_product_differentiating_tech_features_60164_1581516129. std_successorproducts_product_differentiating_tech_features_60165_1581516129. std_successorproducts_product_differentiating_tech_features_60166_1581516129.
Nominal diameter range DN 300 to 1200(12" to 48")
Wetted materials Sensor housing: 1.4404/DN 17440 (316L/AISI)
Weld-in parts: 1.4404/DN 17440 (316L/AISI)
Measuring pipe: ST 37.2 (carbon steel)
Measured variables Volume flow channel 1 or 2, sound velocity, flow velocity, average volume flow, average sound velocity, average flow velocity, totalizer
Max. measurement error +/-0.5 %
Measuring range 0 to 40000 m3/h 0 to 180000GPM
Max. process pressure PN 16, Cl. 150
Medium temperature range -20 to +60°C (-4 to 140°F)
Ambient temperature range Transmitter:
–20 to +60 °C (–4 to +140 °F)
Sensor:
–20 to +80 °C (–4 to +176 °F)
Transmitter housing material Wall-mounted housing: powder-coated die-cast aluminum
Degree of protection Transmitter
IP 67 (NEMA 4X)
Sensor
IP 68 (NEMA 6P)
Display/Operation 4 lines backlit display with three optical keys
Outputs 1x 4-20 mA HART
1x Pulse/frequency/switch output (passive)
Inputs N/A
Digital communication HART, PROFIBUS PA, PROFIBUS DP, FOUNDATION Fieldbus
Power supply AC 85 to 260 V
AC 20 to 55 V
DC 16 to 62V
Hazardous area approvals FM
CSA
Product safety CE, C-Tick

The Prosonic Flow 93C inline flowmeter is designed specifically for water and wastewater flow measurement. The complete system consists of a wall-mounted Prosonic Flow 93 transmitter and an optimally designed Prosonic Flow W insertion sensor. With the Prosonic Flow 93C inline flowmeter, customers benefit from the high accuracy unique to ultrasonic flow measurement systems and from traceable instrument calibration.

Advantages
No production losses - the production process does not need to be interrupted when removing or replacing sensor parts
No pressure loss - full-bore design
High process transparency - diagnostic functions
Optimum performance - extended functions and diagnostic software
Flexible data transmission - a choice of communication methods
Automatic data recovery for service purposes

Application areas
Choice of measuring principle not limited by pressure, density, temperature, conductivity and viscosity
Inline measurement of process water, brine, demineralized water, drinking water and wastewater flow
Instrument features:
International drinking water measurement approval
Nominal diameter: DN 300 ~ 2000 (12~ 80")
Medium temperature: –10 ~ 80 °C (14~ 176 °F)
Aluminum transmitter housing
Four-line backlit display with touch control
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus

Spare Parts & Accessories 48

48 spare parts · click to collapse
Order codeDescription
50099250PSONIC9X Power Supply Module 85-260VACKit power s.b. PSONIC9X 85-260VACDetails
50099252flowmeter communication boardKit P.s.b. PSONIC9X 20-55VAC16-62VDCDetails
50094002fuseKit 10 fuses 250 VAC T800 MADetails
50094003fuseKit Bus/connec.b.5X/40/8X/65 field hous.Details
50106103Measuring amplifier kit PSONIC 93 WEA EXLanguage: FR, ES, IT, NL, PT, DE, ENDetails
50106104Measuring amplifier kit PSONIC 93 EES EXLanguage: SV, FI, NO, RU, PL, CS, ENDetails
50106105Measuring amplifier kit PSONIC 93 SEA EXLanguage: JA, ID, ENDetails
50108136Measurement amplifier kit Psonic 93 CN EXLanguage: ZH + ENDetails
71093786amplifier boardLanguage: FR,ES,IT,NL,PT,DE,ENDetails
71093787amplifier boardLanguage: FR,ES,IT,NL,PT,DE,ENDetails
71093788amplifier boardLanguage: JA,ID,ENDetails
7109378993 Amplifier Board EXLanguage: ZH,ENDetails
50098301Explosion-proof current/frequency output moduleKit com 53/83/93/65 curr/freq. out ExDetails
50098300Explosion-proof Current/Frequency Input Module with 2-Channel Relay OutputKit com 53/83/93/65 curr/freq/2Relay ExDetails
71066579I/O board PA Ex50/53/55/80/83/93/65Details
50109480Kit Com 93 Profibus DP C01 ExDetails
7110761493 Profibus DP C13 Explosion-proof Communication ModuleDetails
50108002Communication module53/55/83/93Details
50101264Kit I/O Foundation Fieldbus C02 ExKit com Pline 53/83/93Found.Fieldbus ExDetails
71095035I/O Board C14 EX53/55/83/93/65Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
All documents for this model
12 documents · click to expand
BA

Proline Prosonic Flow 93 HART ???? Chinese

HART Rev. 1311 132 pages
Preview
BA

Prosonic Flow 93 HART Description of Device Functions English

HART Rev. 1311 154 pages
Preview
BA

Prosonic Flow 93 HART Operating Instructions English

HART Rev. 1311 134 pages
Preview
BA

Prosonic Flow 93C FOUNDATION Fieldbus Description of device functions English

FOUNDATION-Fieldbus Rev. 1310 138 pages
Preview
BA

Prosonic Flow 93C FOUNDATION Fieldbus Operating Instruction English

FOUNDATION-Fieldbus Rev. 1310 90 pages
Preview
BA

Prosonic Flow 93C PROFIBUS DP/PA Description of device functions English

PROFIBUS-DP Rev. 1310 126 pages
Preview
BA

Prosonic Flow 93 HART Operating Instructions English

HART Rev. 0710 134 pages
Preview
BA

Prosonic Flow 93 HART Device Functions English

HART Rev. 0609 151 pages
Preview
BA

Prosonic Flow 93 Device Functions English

156 pages
Preview
BA

Prosonic Flow 93 C Device Functions English

144 pages
Preview
BA

Prosonic Flow 93 C Operating Instructions English

108 pages
Preview
BA

Prosonic Flow 93 C PROFIBUS-DP/-PA Device Functions English

PROFIBUS-DP 184 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Ultrasonic flowmeter — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Ultrasonic flowmeter properly configured on the existing plant, with the aim of transit-time ultrasonic measurement of liquid or gas flow.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Ultrasonic flowmeter configuration has to involve checking straight runs, pipe internal condition and entrained gas.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant checking straight runs, pipe internal condition and entrained gas, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clamp-on versions avoid pipe work, minimising shutdown in revamps, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Ultrasonic flowmeter — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was transit-time ultrasonic measurement of liquid or gas flow.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking straight runs, pipe internal condition and entrained gas.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around checking straight runs, pipe internal condition and entrained gas, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clamp-on versions avoid pipe work, minimising shutdown in revamps, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Ultrasonic flowmeter — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Ultrasonic flowmeter, focusing on transit-time ultrasonic measurement of liquid or gas flow.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Ultrasonic flowmeter specification must therefore cover checking straight runs, pipe internal condition and entrained gas.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on checking straight runs, pipe internal condition and entrained gas, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clamp-on versions avoid pipe work, minimising shutdown in revamps, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Ultrasonic flowmeter — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Ultrasonic flowmeter; the focus is transit-time ultrasonic measurement of liquid or gas flow.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking straight runs, pipe internal condition and entrained gas.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on checking straight runs, pipe internal condition and entrained gas, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clamp-on versions avoid pipe work, minimising shutdown in revamps, which cut the workload on the site maintenance team.