CDC90 Liquiline Control

CDC90 Liquiline Control
Liquiline Control CDC90
The Liquiline Control CDC90 plug & play system automates Memosens pH and ORP measuring points in all industries. It cleans, calibrates and adjusts up to two sensors automatically, reducing maintenance effort, improving working safety in harmful areas and helping to ensure the yield and quality of your product. It can easily be integrated into existing plant infrastructures and allows convenient remote control of your measuring points via any process control system or mobile device.
Compare

pH

Measuring Principle Potentiometric
Application Increased occupational safety by minimizing maintenance and servicing measures.
Customizable cleaning and calibration cycles for up to two measuring points.
Minimization of operating costs and buffer and cleaning agent consumption through smart media distribution and dosing.
Installation Complete automated cleaning and validation system including a selectable retractable holder
Characteristic Fully assembled system with powder-coated or stainless steel pneumatic control unit.
All non-ex applications
Measuring principle Automated cleaning and calibration of Memosens pH and ORP sensors installed in retractable assemblies.
Design Complete cleaning and calibration system including dosing pumps and canisters for buffer and cleaning solutions for connection to various retractable assemblies and sensors
Dimension 268 x 1170 x 770 mm (l x h x w)
10.55 x 46.06 x 28.74 inch (l x h x w)
Connection DCS/PLS connection on Modbus TCP, Ethernet IP, Profinet, ProfibusDP and current in/ output
Input 1 to 2x Memosens digital sensor
1x 0/4 to 20mA input
4x digital input
Output / communication DCS/PLS connection via Modbus TCP, EtherNet/IP, PROFINET, PROFIBUS DP, digital and analog signals
Certificates, declarations and approvals UKCA, CSA general purpose

The Liquiline Control CDC90 is plug & play and automatically performs all tasks at Memosens pH and ORP measuring points in all industries. The system automatically performs cleaning, verification, calibration and adjustment of up to two sensors, reducing maintenance workload, improving workability in harmful conditions and helping to increase product yield and quality. The system can be easily integrated into existing plants, and measuring points can be conveniently controlled remotely via any process control system or remote device.

Benefits
Optimized cleaning and calibration cycles provide reliable, reproducible measured values, helping you to increase product yield and quality while reducing raw material consumption.
In the event of electrode clogging or contamination, the system automatically starts cleaning and calibration, always providing reliable measured values and ensuring product safety.
Minimizes maintenance workload at hard-to-reach positions, under demanding conditions or in harmful environments, increasing the safety of service personnel.
Offers various certified communication methods for seamless integration into your process control system, e.g.: 0/4…20mA, PROFIBUS DP, Modbus TCP, EtherNet/IP, PROFINET and OPC UA as well as web server technology.
Pre-configured cleaning and calibration programs enable fast startup and commissioning of the Liquiline Control CDC90 at low operating cost.

Applications
The Liquiline Control CDC90 automatically performs all tasks at pH and ORP measuring points in all industries. Suitable for the following applications:
Electrodes must be cleaned and/or calibrated frequently.
Measuring points are difficult to access.
Measuring points are in harmful environments.
The process requires repeated high-precision pH measurement.
The process requires frequent measurement.
Measuring point performance must be frequently checked and documented.

   

 

 

Source: Endress+Hauserpublic information from the website

Measuring principle video

Click to play

Spare Parts & Accessories 78

78 spare parts · click to collapse
Order codeDescription
71361216Kit CDC90 Cover without ElectronicsDetails
71379312CDC90 Interface Board KitDetails
71379315Kit CDC90 PROFINET cable M12 - RJ45Details
71379318CDC90 Profibus gateway module kitDetails
71379319Kit CDC90 Gateway module ProfinetDetails
71518246Kit CDC90 Gateway EtherNet/IPDetails
71518244Kit CDC90 Ethernet cable M12-RJ45 90°Details
71518248Kit CDC90 USB Stick 64 GBDetails
71518249Kit CDC90 Cable glands control unitDetails
71361218Kit CDC90 air filterDetails
71361219Kit CDC90 wall holder V4ADetails
71379320Kit CDC90 wall holder, coated steelDetails
71361221Kit CDC90 valve block, 8 valvesDetails
71361222Kit CDC90 valve block, 16 valvesDetails
71677033Kit CDC90 valveblock 16 valves A2Details
71361223Kit CDC90 valve module 2x (NC)Details
71361225Kit CDC90 valve module 2x (NO)Details
71481481Kit CDC90 valve module 5/2-wayDetails
71677034Kit CDC90 medium valve A2Details
71361230CDC90 pneumatic pressure monitor kitDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
All documents for this model
12 documents · click to expand
BA

BA Liquiline Control CDC90 Chinese

Rev. 0924 96 pages
Preview
BA

BA Liquiline Control CDC90 Chinese

Rev. 0326 28 pages
Preview
BA

BA Liquiline Control CDC90 Chinese

Rev. 0326 28 pages
Preview
BA

BA Liquiline Control CDC90 Chinese

Rev. 0326 24 pages
Preview
BA

BA Liquiline Control CDC90 Chinese

Rev. 0326 28 pages
Preview
BA

BA Liquiline Control CDC90 Chinese

Rev. 0224 12 pages
Preview
BA

BA Liquiline Control CDC90 English

Rev. 0924 102 pages
Preview
BA

BA Liquiline Control CDC90 English

Rev. 0326 28 pages
Preview
BA

BA Liquiline Control CDC90 English

Rev. 0326 28 pages
Preview
BA

BA Liquiline Control CDC90 English

Rev. 0326 28 pages
Preview
BA

BA Liquiline Control CDC90 English

Rev. 0326 28 pages
Preview
BA

BA Liquiline Control CDC90 English

Rev. 0224 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · PH — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · PH — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is PH; the focus is continuous pH monitoring for neutralisation and compliance control.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing glass or ISFET sensors by temperature, fluoride content and pressure, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means tighter dosing control and lower reagent consumption, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · PH — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on PH and the core task is continuous pH monitoring for neutralisation and compliance control.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So PH cannot be specified generically — it calls for choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing glass or ISFET sensors by temperature, fluoride content and pressure, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is tighter dosing control and lower reagent consumption.

Power & Energy

Power & Energy · PH — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted PH properly configured on the existing plant, with the aim of continuous pH monitoring for neutralisation and compliance control.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the PH configuration has to involve choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing glass or ISFET sensors by temperature, fluoride content and pressure, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is tighter dosing control and lower reagent consumption, and the readings are now used for process tuning.