Ceraliquid CPS41D is the digital high performer for harsh chemical applications, media with low conductivity or a considerable content of organic solvents. The sensor is designed for fast response guaranteeing you high process safety even in applications with fast-changing media. Ceraliquid CPS41D is not the latest Memosens generation. To get information on the new Memosens CPS41E sensor with extended functionality, click here.
Compare

pH

Measuring Principle
Application Chemical industry, organic chemicals, power stations, food industry, laboratory measurements
Characteristic Analog or digital pH electrodes for process engineering with ceramic diaphragm
and KCl liquid electrolyte
Measuring range pH 0 to 14
Measuring principle Liquid-KCl with ceramic diaphragm
Design All shaft lengths with temperature sensor
Digital electrode with Memosens technology
Material Glass and ceramic
Dimension Diameter: 12 mm (0.47 inch)
Shaft length: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.17 and 16.73 inch)
Process temperature 0 to 135 °C (32 to 275 °F)
Process pressure 1 to 11 bar abs (15 to 160 psi)
Temperature sensor NTC30k
Ex certification ATEX, FM, CSA
Connection Contactless, inductive, digital connection head with Memosens technology
Ingress protection IP68
Certificates, declarations and approvals 3A, EHEDG

The Ceraliquid CPS41D is a high-performance digital electrode for demanding conditions, low-conductivity media and highly concentrated organic solvents in the chemical industry. Even in applications with rapidly changing media, the fast response of the electrode ensures high process safety. With Memosens digital technology, the CPS41D offers maximum process and data integrity combined with simple operation. The electrode is corrosion-resistant and moisture-proof, and supports laboratory calibration and device pre-maintenance.

Benefits

  • Continuous KCl electrolyte replenishment and a separate reference lead give the electrode its poison-resistant properties

  • With KCl electrolyte, can measure media with very low conductivity (= 0.1 µS/cm)

  • Suitable for CIP and SIP cleaning

  • Perfect for applications with rapidly changing media: the combination of liquid KCl electrolyte and ceramic diaphragm shortens the response time

  • Non-contact inductive signal transmission ensures maximum process safety

  • Stores sensor characteristic parameters for predictive maintenance

  • Reduces process downtime, extends sensor service life and lowers operating costs

 

Application areas

  • Suitable for measuring low-conductivity media, highly concentrated organic solvents or alcohols, and rapidly changing media

  • Chemical industry

  • Power plants, e.g. boiler feed water

  • Life sciences, e.g. water for injection

  • ATEX, FM and CSA approved, suitable for explosion hazardous areas

Spare Parts & Accessories 5

5 spare parts · click to collapse
Order codeDescription
71038228*** sensorfor assignment of sensors to measuring loop. 100 sensor clips with printable labelsDetails
71538217CPSxx electrode protection cap20 pc protective caps for pH sensors CPSxxDetails
CPY4-KCl electrolyte CPY4For liquid filled electrodesEnquire
CPY20-pH buffer solution CPY20pH quality buffer solution, referenced to primary reference material of PTB and standard reference material of NIST. With calibration certificate buffer solutionEnquire
CPY7B-Electrolyte Cell CPY7BKCl Electrolyte reservoir CPY7B Storage for liquid KCl Liquid KCl filled pH- and ORP electrodes: CPS41(E), CPS42(E), CPS47E ::Pressureless and pressurized ::Safe and reliable pH measurementsEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play
1 models · click to collapse
All documents for this model
11 documents · click to expand
BA

BA CPSx1, CPFx1 pH电极 CPSx2, CPFx2 ORP电极 Chinese

Rev. 0426 20 pages
Preview
BA

BA CPSx1, CPFx1 pH sensors CPSx2, CPFx2 ORP sensors English

Rev. 0426 20 pages
Preview
BA

pH-/Redoxsensoren und Referenzhalbzellen pH/ORP sensors and reference half cells Operating Instructions English

Rev. 0217 16 pages
Preview
TI

TI Orbisint CPS11 Chinese

Rev. 1725 12 pages
Preview
TI

技术资料 Ceraliquid CPS41, CPS41D Chinese

Rev. 1315 16 pages
Preview
TI

技术资料 Ceraliquid CPS41, CPS41D Chinese

Rev. 0305 16 pages
Preview
TI

技术资料 Orbisint CPS11, CPS11D Chinese

Rev. 0208 12 pages
Preview
TI

TI Orbisint CPS11 English

Rev. 1725 12 pages
Preview
TI

Technical Information CPS41, CPS41D English

Rev. 1315 16 pages
Preview
TI

Technical Information Orbisint CPS11/CPS11D English

Rev. 0208 12 pages
Preview
TI

Technical Information CPS41, CPS41D English

16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · PH — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · PH — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is PH; the focus is continuous pH monitoring for neutralisation and compliance control.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing glass or ISFET sensors by temperature, fluoride content and pressure, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means tighter dosing control and lower reagent consumption, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · PH — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on PH and the core task is continuous pH monitoring for neutralisation and compliance control.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So PH cannot be specified generically — it calls for choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing glass or ISFET sensors by temperature, fluoride content and pressure, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is tighter dosing control and lower reagent consumption.

Power & Energy

Power & Energy · PH — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted PH properly configured on the existing plant, with the aim of continuous pH monitoring for neutralisation and compliance control.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the PH configuration has to involve choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing glass or ISFET sensors by temperature, fluoride content and pressure, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is tighter dosing control and lower reagent consumption, and the readings are now used for process tuning.