Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CPS71E Digital pH sensor

CPS71E  Digital pH sensor
Memosens CPS71E
Configurable Models 15 models
Memosens 2.0 pH electrode for chemical processes and poisoning media
Compare

pH

Measuring Principle Potentiometric
Application Process technology and monitoring of processes with:
• Rapidly changing pH values
• High proportion of electrode poisons such as H2S
Characteristic Digital pH electrode for chemical process with an ion trap for poison-resistant reference
Measuring range Application B:
• pH: 0 to 14
Application H:
• pH: 0 to 12
Measuring principle Gel compact electrode with ceramic junction and ion trap
Design All shaft lengths with temperature sensor
Advanced gel technology
Material Sensor shaft: Glass to suit process
pH membrane glass: Type B, Type N
Metal lead: Ag/AgCl
Open aperture: Ceramic junction, zirconium dioxide
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide
Dimension Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.2 and 16.7 inch)
Process temperature 1 to 140 °C (32 to 284 °F)
Process pressure 0,8 to 14 bar (11,6 to 203 psi) (absolute)
Temperature sensor NTC 30k
Ex certification With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2.
Connection Inductive, contactless connection head with Memosens 2.0 technology
Ingress protection IP68

Field of application
Memosens CPS71E is specially designed for demanding processes. Its unique, contamination-resistant reference and its resistance to moisture ensure reliable measurement even in heavily polluted, aggressive media such as strong acids and bases. Thanks to Memosens 2.0 digital technology, CPS71E offers extended storage of calibration and process data providing the perfect basis for predictive maintenance. Pre-calibration in the lab and quick sensor exchange on site maximize process uptime.
Processes in chemical industry and monitoring of processes with:
High proportion of electrode poisons such as H2S
Quickly changing pH values
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.

Benefits
The electrode's unique ion trap prevents poisoning of the junction and reference, making it resistant to strong acids and bases and ensuring a long sensor lifetime.
The optional pressurized reference allows for reliable measurement in blocking media such as dispersions.
Flexible installation thanks to optional upside-down mounting
Inductive cable connection and non-contact signal transmission eliminate any problems due to moisture or corrosion and increase process integrity.
Fast sensor exchange on site reduces process downtime and operating costs.
Memosens 2.0 digital technology makes trend identification and predictive maintenance possible thanks to its extended storage of calibration and process data. The technology paves the way for advanced IIoT services.

 

pH:

Measuring Principle Potentiometric
Application Process technology and monitoring of processes with:
• Rapidly changing pH values
• High proportion of electrode poisons such as H2S
 
Characteristic Digital pH electrode for chemical process with an ion trap for poison-resistant reference
Measuring range Application B:
• pH: 0 to 14
Application H:
• pH: 0 to 12
 
Measuring principle Gel compact electrode with ceramic junction and ion trap
Design All shaft lengths with temperature sensor
Advanced gel technology
 
Material Sensor shaft: Glass to suit process
pH membrane glass: Type B, Type N
Metal lead: Ag/AgCl
Open aperture: Ceramic junction, zirconium dioxide
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide
Dimension Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.2 and 16.7 inch)
Process temperature 1 to 140 °C (32 to 284 °F)
Process pressure 0,8 to 14 bar (11,6 to 203 psi) (absolute)
Temperature sensor NTC 30k
Ex certification With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2.
Connection Inductive, contactless connection head with Memosens 2.0 technology
Ingress protection IP68

Measuring principle video

Click to play

Spare Parts & Accessories 5

5 spare parts · click to collapse
Order codeDescription
71038228*** sensorfor assignment of sensors to measuring loop. 100 sensor clips with printable labelsDetails
71038229*** cablefor assignment of Sensors to measuring loop. 50 cable labels with printable labels.Details
71538217CPSxx electrode protection cap20 pc protective caps for pH sensors CPSxxDetails
CPY4-KCl electrolyte CPY4For liquid filled electrodesEnquire
CPY20-pH buffer solution CPY20pH quality buffer solution, referenced to primary reference material of PTB and standard reference material of NIST. With calibration certificate buffer solutionEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
15 models · click to collapse
All documents for this model
4 documents · click to expand
BA

BA pH电极CPSx1E, CPFx1E ORP电极CPSx2E, CPFx2E Chinese

Rev. 0526 20 pages
Preview
BA

BA pH sensors CPSx1E, CPFx1E ORP sensors CPSx2E, CPFx2E English

Rev. 0526 20 pages
Preview
TI

TI Memosens CPS71E Chinese

Rev. 0325 12 pages
Preview
TI

TI Memosens CPS71E English

Rev. 0325 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · PH — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · PH — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is PH; the focus is continuous pH monitoring for neutralisation and compliance control.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing glass or ISFET sensors by temperature, fluoride content and pressure, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means tighter dosing control and lower reagent consumption, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · PH — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on PH and the core task is continuous pH monitoring for neutralisation and compliance control.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So PH cannot be specified generically — it calls for choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing glass or ISFET sensors by temperature, fluoride content and pressure, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is tighter dosing control and lower reagent consumption.

Power & Energy

Power & Energy · PH — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted PH properly configured on the existing plant, with the aim of continuous pH monitoring for neutralisation and compliance control.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the PH configuration has to involve choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing glass or ISFET sensors by temperature, fluoride content and pressure, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is tighter dosing control and lower reagent consumption, and the readings are now used for process tuning.