Memosens CPS97D is the specialist for fibrous media or media with a high content of suspended solids such as dispersions, precipitation, emulsions. Its unbreakable shaft ensures a long operating life while the open aperture guarantees reliable measurement under harsh process conditions. Memosens CPS97D is not the latest Memosens generation. To get information on the new Memosens CPS97E sensor with extended functionality, click here.
Compare

pH

Measuring Principle
Application Chemical industry, pulp and paper, primaries and metal, mining, minerals & metals
Characteristic Unbreakable
Useable in highliest clogging media, e.g. suspended solides, dispersion, precipitation reaction
Needs min. conductivity of >500µS/cm
Reference Stabilized gel reference system
Measuring range pH 0 to 14
Material Sensor shaft: PEEK
Sealing: FFKM
Dimension Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.2 and 16.7 inch)
Process temperature -15 to 110 °C (5 to 230 °F)
Process pressure Max. 11 bar abs. at 100 °C
(Max. 159.5 psi at 212 °F)
Temperature sensor Pt1000
Connection Inductive, digital connection head with Memosens technology
Ingress protection IP 68 (10 m (33 ft) water column, 25 °C (77 °F), 45 days)

The Memosens CPS97D is the specialist for measuring fibrous media or media with high suspended solids concentration (e.g. dispersions, precipitants, emulsions). The electrode shaft does not break and has a long service life; the open aperture enables reliable measurement under harsh conditions. In addition, the Memosens digital technology offers maximum process and data integrity with simple operation. The electrode is moisture- and corrosion-resistant, allows laboratory calibration and enables predictive maintenance.

Advantages
The sensor does not break, guaranteeing maximum product safety
Open aperture design, suitable for measuring heavily contaminated media
Chemically stable reference gel for long-term stable measurement results
Allows measurement at low temperatures
Long calibration intervals, low maintenance effort
Non-contact inductive signal transmission with maximum process safety
Stores sensor and process parameters, allowing predictive maintenance

Field of application
• Chemical processes
• Pulp and paper industry
• Contaminated media and suspended solids
- dispersions
- precipitants
- emulsions

 

Spare Parts & Accessories 3

3 spare parts · click to collapse
Order codeDescription
71038228*** sensorfor assignment of sensors to measuring loop. 100 sensor clips with printable labelsDetails
CPY4-KCl electrolyte CPY4For liquid filled electrodesEnquire
CPY20-pH buffer solution CPY20pH quality buffer solution, referenced to primary reference material of PTB and standard reference material of NIST. With calibration certificate buffer solutionEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

A

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
All documents for this model
4 documents · click to expand
BA

CPS47D, CPS77D, CPS97D Chinese

Rev. 0320 16 pages
Preview
BA

CPS47D/77D/97D English

Rev. 0320 20 pages
Preview
TI

Memosens CPS97D Chinese

Rev. 0220 16 pages
Preview
TI

Memosens CPS97D English

Rev. 0220 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · PH — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · PH — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is PH; the focus is continuous pH monitoring for neutralisation and compliance control.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing glass or ISFET sensors by temperature, fluoride content and pressure, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means tighter dosing control and lower reagent consumption, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · PH — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on PH and the core task is continuous pH monitoring for neutralisation and compliance control.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So PH cannot be specified generically — it calls for choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing glass or ISFET sensors by temperature, fluoride content and pressure, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is tighter dosing control and lower reagent consumption.

Power & Energy

Power & Energy · PH — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted PH properly configured on the existing plant, with the aim of continuous pH monitoring for neutralisation and compliance control.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the PH configuration has to involve choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing glass or ISFET sensors by temperature, fluoride content and pressure, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is tighter dosing control and lower reagent consumption, and the readings are now used for process tuning.