Technical Data
CompareWatersampler
| Measuring Principle | Sampler |
| Functions | Stationary sampler |
| Application | Communal and industrial wastewater treatment plants Laboratories and water management offices Monitoring of liquid media in industrial processes |
| Dosing system | Vacuum pump system Peristaltic pump system Armature |
| Suction height | 6 m (19.69 ft) suction height 8 m (26.25 ft) suction height |
| Cabinet | Plastic PS Plastic ASA+PC Stainless Steel V2A Stainless Steel V4A |
| Distribution | Possible |
| Process temperature | Sample temperature: 2 to 50 °C (36 to 122 °F) |
| Cooling | Active, dynamic cooling unit |
| Process pressure | Max. 0.8 bar (Max. 11.6 psi) |
| Heating | Evaporator and defrosting unit mounted in compact housing |
| Input | Analogue: 2, galvanically isolated Binary: 2, galvanically isolated Optional: 1 to 4 digital sensors |
| Output / communication | Binary: 2, galvanically isolated Optional 2 to 6 relay, 2 to 6 current output |
| Interface | CDI Optional: Ethernet, PROFIBUS DP, Modbus RS485, Modbus TCP |
| Data logger | All events and data Sampling statistics |
| Power supply | Depending on version: 100 to 120/200 to 240 V AC ±10 %, 50/60 Hz 24 V DC +15/‐9 % |
| Dimension | 1.258 x 753 x 625 mm (h x w x d) 49.5 x 29.7 x 24.6 inch (h x w x d) |
| Weight | 91 to 146 kg |
| Accessories | Sampling from pressurized systems Dosing system Housing equipment Electrical equipment |
| Options | Connection to digital sensors with Memosens protocol, Fieldbuscommunication |
Safe and convenient sampling. The Liquistation CSF48 automatic water sampler complies with global water resource protection regulations and is equipped with a fail-safe cooling system and an explosion-proof housing to ensure absolute sample safety. Guided menu sampling programs and tool-free maintenance effectively save you time in your daily work. Liquistation can be upgraded to a complete measuring station for modern environmental monitoring, helping you respond flexibly to future requirements at any time.
Advantages
-
Automatic water sampling in full compliance with all relevant national and international standards such as ISO 5667
-
Handles all monitoring tasks, from time- or flow-controlled sampling to event-controlled sampling
-
Connect up to four Memosens sensors to upgrade the sampler to a full measuring station (e.g. for event monitoring)
-
Offers all the advantages of the Liquiline platform, such as: uniform operation of all devices, easy expansion and reduced spare parts inventory through standardized components
-
Fieldbus communication and remote access via web server for full integration into any process control system
-
Tool-free removal of wetted parts for fast cleaning and maintenance
-
Heartbeat Technology enables condition-based maintenance, saving resources and costs
Application areas
-
Liquistation CSF48 is suitable for the following applications:
-
Municipal and industrial wastewater treatment plants:
-
Self-monitoring
-
Process monitoring
-
Indirect discharge monitoring
-
Sludge system monitoring
-
Water quality monitoring authorities:
-
Water resource protection and water quality monitoring
-
Direct and indirect discharge monitoring
Spare Parts & Accessories 222
222 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| CSV18- | Sampling Instrument Maintenance Kit CSV18Maintenance kit for Liquistation CSFxx / Liquiport CSP44. Yearly maintenance: Contains components to be replaced within one year. Large maintenance: Contains components for annual maintenance and additional wear parts. Recommended replacement every 3-5 years. | Enquire |
| 71309358 | CSF48 Spare Parts: Compressor Maintenance Spare Parts | Details |
| 71113947 | ***Kit CSF48 maintenance vacuum acrylic 1y | Details |
| 71113949 | CSF48 Maintenance Vacuum Glass Kit, 1 Year | Details |
| 71114090 | CSF48 maintenance kit, large vacuum, 6 m | Details |
| 71114091 | Kit CSF48 maintenance large vacuum 8m | Details |
| 71113950 | Kit CSF48: peristaltic maintenance, 1 year | Details |
| 71115558 | CSF48 maintenance kit, large, peristaltic | Details |
| 71139091 | CSF48 Air Conditioning Assembly: Base | Details |
| 71644400 | Kit CSFxx cooling module entry sealantCSFxx climate module sealing compound for sealing the cable entry. | Details |
| 71139088 | CSF48: Base Module Data Cable | Details |
| 71103292 | CSF48: Power supply 90-230 V ACOld kit name: Kit CSF48: Power supply 90-230 V AC | Details |
| 71101762 | CM442/CM444/CM448/CSF48 display cable accessoryCM44x/CSF48/CA8x | Details |
| 71113885 | CSF40: Rechargeable battery pack | Details |
| 71101959 | CSF48 Distribution Rod Drive Motor | Details |
| 71110970 | CSF48: Downpipe | Details |
| 71098113 | distribution arm | Details |
| 71113519 | CSF48: Rotary Water Faucet Shaft | Details |
| 71138061 | CSF48: Cylinder Lock | Details |
| 71143162 | CSF48: Plastic top | Details |
Configurator / Comparison
Accessories / Spare parts
Source:Endress+Hauserpublic information from the website
12 documents · click to expand
Liquistation CSF48 Chinese
Memosens Chinese
Liquistation CSF48 English
Liquistation CSF48 English
Liquistation CSF48 English
Operating Instructions Liquistation CSF48 English
Operating Instructions English
Operating Instructions English
Operating Instructions English
Memosens English
Operating Instructions English
Operating Instructions English
Product Videos
View allCase Studies
Municipal Wastewater Treatment · EH-ONLINE — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted EH-ONLINE properly configured on the existing plant, with the aim of continuous water monitoring on the E+H online platform.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the EH-ONLINE configuration has to involve configured under one numbering scheme across platform protocols and sensors.
Configuration
Supply and installation were organised through the online water-analysis line: integrating around each online monitoring point. On site this meant configured under one numbering scheme across platform protocols and sensors, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is data flows through the platform, improving service and diagnostics, and the readings are now used for process tuning.
Food & Beverage · EH-ONLINE — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous water monitoring on the E+H online platform.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means configured under one numbering scheme across platform protocols and sensors.
What We Did
We took a online water-analysis line approach — integrating around each online monitoring point. Delivery was built around configured under one numbering scheme across platform protocols and sensors, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — data flows through the platform, improving service and diagnostics, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · EH-ONLINE — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from EH-ONLINE, focusing on continuous water monitoring on the E+H online platform.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The EH-ONLINE specification must therefore cover configured under one numbering scheme across platform protocols and sensors.
Delivery Approach
Delivery was handled as the online water-analysis line — integrating around each online monitoring point. Execution centred on configured under one numbering scheme across platform protocols and sensors, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — data flows through the platform, improving service and diagnostics, with confidence in this measuring point improving markedly.
Power & Energy · EH-ONLINE — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is EH-ONLINE; the focus is continuous water monitoring on the E+H online platform.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with configured under one numbering scheme across platform protocols and sensors.
Implementation
The scope ran through the online water-analysis line: integrating around each online monitoring point. Technically it hinges on configured under one numbering scheme across platform protocols and sensors, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means data flows through the platform, improving service and diagnostics, which cut the workload on the site maintenance team.
Related Products
Endress+HauserLiquiline System CA80COD
Endress+HauserTotal nitrogen analyzer
Endress+HauserLiquiline System CA80AM
Endress+HauserViomax CAS51D
Endress+HauserISEmax sensor CAS40D
Endress+HauserLiquiline System CA80TP
Endress+HauserLiquiline System CA80SI
Endress+Hauser