CYP03D Digital Simulator

CYP03D Digital Simulator
Memocheck Sim CYP03D
Comprehensive Memosense measurement point inspection, applicable to all industries
Compare

Conductivity

Measuring Principle Conductive
Application Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
Installation Temporary connection via Memosens cable with inductive coupling
Measuring range Ranges like the simulated sensors
Dimension Handheld:
94 x 236 x 25 to 40 mm
3.7 x 9.29 x 0.98 to 1.57 inch
Process temperature Umgebungstemperatur: –20 to 50 °C (–4 to 120 °F)
Ex certification ATEX, IECEx, CSA
Connection Battery powered
Ingress protection IP65

Disinfection

Measuring Principle Free chlorine
Application Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
Measuring range Ranges like the simulated sensors
Dimension Handheld:
94 x 236 x 25 to 40 mm
3.7 x 9.29 x 0.98 to 1.57 inch
Process temperature Ambient temperature: –20 to 50 °C (–4 to 120 °F)
Connection Battery powered

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
Installation Temporary connection via Memosens cable with inductive coupling
Measuring range Ranges like the simulated sensors
Dimension Handheld:
94 x 236 x 25 to 40 mm
3.7 x 9.29 x 0.98 to 1.57 inch
Process temperature Ambient temperature: –20 to 50 °C (–4 to 120 °F)
Ex certification ATEX, IECEx, CSA
Connection Battery powered
Ingress protection IP65

Oxygen

Measuring Principle Amperometric oxygen measurement
Application Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
Installation Temporary connection via Memosens cable with inductive coupling
Measuring range Ranges like the simulated sensors
Dimension Handheld:
94 x 236 x 25 to 40 mm
3.7 x 9.29 x 0.98 to 1.57 inch
Process temperature Ambient temperature: –20 to 50 °C (–4 to 120 °F)
Ex certification ATEX: Ex ia, zone 0
Connection Battery powered
Ingress protection IP65

Turbidity

Measuring Principle Single beam scattered light
Application Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol.
Multiparameter, main- and secondary values
Installation Temporary connection via Memosens cable with inductive coupling.
Measuring range Ranges like the simulated sensors.
Dimension Handheld, 9,5 x 23,5 x 3,5 cm
Process temperature -20...55°C ambient temperature
Ex certification ATEX: Ex ia, zone 1
Connection Battery powered
Ingress protection IP65

pH

Measuring Principle Potentiometric
Application Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
Installation Temporary connection via Memosens cable with inductive coupling
Measuring range Ranges like the simulated sensors
Dimension Handheld:
94 x 236 x 40 mm
3.7 x 9.29 x 1.57 inch
Process temperature Ambient temperature: –20 to 50 °C (–4 to 120 °F)
Ex certification ATEX, IECEx, CSA
Connection Battery powered
Ingress protection IP65

Memocheck Sim CYP03D is a flexible service and certification tool for all applications. It simulates definable values to support your installation, debugging, and troubleshooting. Memocheck Sim can replace the sensor, check the complete measurement loop from the cable connector to the process control system, and verify that the transmission of the measured value is zero error. The Memocheck Sim with quality certification is selected to certify the entire measuring point.

advantage
Fast and reliable function check: freely definable measured values and amplitudes for flexibility in installation, commissioning, troubleshooting and factory certification
Suitable for controlled environments: Quality certification and traceable calibration certificates are available
Improve the safety of the measuring loop: check the complete measuring loop from the cable connector to the process control system
All parameters available in one tool: pH, ORP, conductivity, dissolved oxygen, residual chlorine, turbidity and nitrate and SAC
Explosion-proof certified for use in explosion-hazardous areas

Application areas
Factory Certification
Installation and commissioning
fault diagnosis

 

 

Accessories/Spare Parts

Source:Endress Hauserwebsite public information

Measuring principle video

Click to play

Spare Parts & Accessories 2

2 spare parts · click to collapse
Order codeDescription
71138380CYP03: Battery Compartment CoverDetails
71240431CYP03D carrying bagDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
All documents for this model
6 documents · click to expand
BA

Memocheck Sim CYP03D 操作手册 Chinese

Rev. 1919 52 pages
Preview
BA

Memocheck Sim CYP03D Operating Instructions English

Rev. 1919 56 pages
Preview
TI

Memocheck CYP02D / Memocheck Sim CYP03D 技术资料 Chinese

Rev. 1718 12 pages
Preview
TI

技术资料 Memocheck Plus CYP01D Memocheck CYP02D Memocheck Sim CYP03D Chinese

Rev. 1412 12 pages
Preview
TI

Memocheck CYP02D / Memocheck Sim CYP03D Technical Information English

Rev. 1718 12 pages
Preview
TI

Technical Information Memocheck Plus CYP01D / Memocheck CYP02D / Memocheck Sim CYP03D English

Rev. 1310 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · multiparameter — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from multiparameter, focusing on monitoring several water parameters at one measuring point.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The multiparameter specification must therefore cover configured by parameter set, mounting and cleaning needs.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on configured by parameter set, mounting and cleaning needs, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — one point replacing several single-parameter units, saving capex and upkeep, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · multiparameter — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is multiparameter; the focus is monitoring several water parameters at one measuring point.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with configured by parameter set, mounting and cleaning needs.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on configured by parameter set, mounting and cleaning needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means one point replacing several single-parameter units, saving capex and upkeep, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · multiparameter — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on multiparameter and the core task is monitoring several water parameters at one measuring point.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So multiparameter cannot be specified generically — it calls for configured by parameter set, mounting and cleaning needs.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves configured by parameter set, mounting and cleaning needs, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is one point replacing several single-parameter units, saving capex and upkeep.

Power & Energy

Power & Energy · multiparameter — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted multiparameter properly configured on the existing plant, with the aim of monitoring several water parameters at one measuring point.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the multiparameter configuration has to involve configured by parameter set, mounting and cleaning needs.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant configured by parameter set, mounting and cleaning needs, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is one point replacing several single-parameter units, saving capex and upkeep, and the readings are now used for process tuning.