D9TB Portable ultrasonic concentration meter

D9TB Portable ultrasonic concentration meter
Portable ultrasonic concentration meter D9TB
The portable Teqwave T offers the most flexible application possibilities for temporary in situ liquid analysis in your plant or laboratory. With just one device, you can monitor concentration values at various measuring points and thus maximize your product quality at minimum operational expenditure. The mobile transmitter with its pre-configured measuring points allows you to use Teqwave T perfectly matched to your production needs.
Compare

Concentration

Measuring Principle Ultrasonic concentration
Product headline Smart, mobile measuring device – individually for your process.
Easy, fast and efficient – real-time in situ liquid analysis.
Temporary concentration measurement of liquids at various measuring points in plant and laboratory.
Sensor features Versatile applications – one device for changing tasks. Highest process safety – reliable metering due to robust, maintenance-free sensor. Cost-saving – surveillance of product quality without sampling.
Insertion length: 180 mm (7 in). Accurate and independent of flow profile.
Transmitter features Customized usage – innovative application concept, expendable for changing measuring tasks. Fast, straightforward operation without metrology knowledge – pre-configured measuring points. Efficient plant monitoring – up to 8 hours of mobile operation without external power supply.
Robust, portable transmitter with Li-ion battery 2300 mAh. Large color display with 4 operating keys. Integrated data storage for max. 3000 measured values.
Nominal diameter range Insertion length: 180 mm (7")
Measured variables Concentration, temperature, sound velocity (internal variable), acoustic density (internal variable), dispersion (internal varibale)
Max. measurement error Density: ±0.01g/cm³ (internal variable)
Temperature: ±0.5K
Sound velocity: 2m/s (internal variable)
Measuring range Concentration According to concentration app data sheet, maximum 0 to 100 %
Sound velocity 600 to 2000 m/s
Temperature maximum 0 to +100 °C (32 to +212 °F)
Acoustic Density 0.7 to 1.5 g/cm³
Design Portable
Material Sensor material: Stainless steel 1.4571 (316 Ti)
Transmitter housing material: ABS plastic
Process temperature 0 to 100 °C (32 to 212 °F)
Ex certification Non-hazardous area
Ingress protection Sensor: IP68 (with plugged in cable)
Transmitter: IP65
Display/Operation 3.5" TFT display with 4 operating keys
Outputs USB
Power supply Lithium-ion battery (2300 mAh capacity)
Product safety CE, UKCA, RCM

Density/Concentration

Measuring Principle Ultrasonic concentration
Product headline Smart, mobile measuring device – individually for your process.
Easy, fast and efficient – real-time in situ liquid analysis.
Temporary concentration measurement of liquids at various measuring points in plant and laboratory.
Sensor features Versatile applications – one device for changing tasks. Highest process safety – reliable metering due to robust, maintenance-free sensor. Cost-saving – surveillance of product quality without sampling.
Insertion length: 180 mm (7 in). Accurate and independent of flow profile.
Transmitter features Customized usage – innovative application concept, expendable for changing measuring tasks. Fast, straightforward operation without metrology knowledge – pre-configured measuring points. Efficient plant monitoring – up to 8 hours of mobile operation without external power supply.
Robust, portable transmitter with Li-ion battery 2300 mAh. Large color display with 4 operating keys. Integrated data storage for max. 3000 measured values.
Nominal diameter range Insertion length: 180 mm (7")
Wetted materials Stainless steel1.4571 (316 Ti)
Measured variables Concentration, sound velocity (internal variable), temperature, acoustic density (internal variable), dispersion (internal variable)
Max. measurement error Acoustic density: ±0.01g/cm³ (interal measuring variable)
Temperature: ±0.5K
Sound velocity: +-2m/s (interal measuring variable)
Measuring range Concentration According to concentration app data sheet, maximum 0 to 100 %
Sound velocity 600 to 2000 m/s (interal measuring variable)
Temperature maximum 0 to +100 °C (32 to +212 °F)
Acoustic Density 0.7 to 1.5 g/cm³ (interal measuring variable)
Medium temperature range 0 to 100 °C (32 to 212 °F)
Ambient temperature range 0…40 °C (32...122 °F)
Sensor housing material Stainless steel 1.4571 (316 Ti)
Transmitter housing material ABS plastic and glas
Degree of protection Sensor: IP68
Transmitter: IP65
Display/Operation 3.5" TFT display with operating keys
Outputs USB
Power supply Lithium-ion battery (2300 mAh capacity)
Hazardous area approvals Non-hazardous area
Product safety CE, UKCA, RCM
  • The portable Teqwave T can temporarily measure the concentration at multiple measuring points in plants and laboratories, flexibly meeting various application requirements. A single instrument can monitor the concentration values of multiple measuring points, achieving the highest product quality at the lowest operating cost. The mobile transmitter with a dedicated app and preset measuring points enable users to optimize the use of the Teqwave T according to production requirements.

    Benefits
    Simple, fast and efficient: real-time online liquid analysis
    Wide range of applications: a single instrument meets the requirements of multiple measuring tasks
    Maximum process safety: robust, maintenance-free sensor with reliable measurement
    Economical: product quality monitoring without sampling inspections
    Customized on demand: innovative app concept, simple retrofitting and upgrading, easy handling of all kinds of measuring tasks
    Fast, direct instrument operation without metrology expertise: preset measuring points
    Efficient plant monitoring: up to 8 hours of mobile operation without an external power supply

    Applications
    The waveguide acoustic monitoring technology measures precisely and reliably, safely detecting even the smallest changes
    Can temporarily measure the concentration at multiple measuring points in plants and laboratories
    Device features
    High measurement accuracy, unaffected by the flow profile
    Insertion depth: 180 mm (7")
    Robust portable transmitter powered by a 2300 mAh lithium battery
    Large color display with 4 operating keys
    Integrated data storage unit for up to 3000 measured values

 

Spare Parts & Accessories 3

3 spare parts · click to collapse
Order codeDescription
XPD0047-Cable-separated version, TeqwaveConnection cable between Sensor and Transmitter.Enquire
D9TB-Teqwave T, D9TB, mobileUltrasonic concentration meter Mobile version. Application: Temporary concentration measurement of liquids at various measuring points in plant + laboratory. Accurate, independent of flow profile. Innovative application concept. Transmitter: robust with Li-ion battery. :: Mobile measuring device – smart, highly flexibel and individual. :: Easy, fast and efficient – real-time in situ liquid analysis.Enquire
DK9500-Teqwave Concentration AppsEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source: Endress+Hauserpublic information from the website

Measuring principle video

Click to play
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Ultrasonic flowmeter — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Ultrasonic flowmeter properly configured on the existing plant, with the aim of transit-time ultrasonic measurement of liquid or gas flow.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Ultrasonic flowmeter configuration has to involve checking straight runs, pipe internal condition and entrained gas.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant checking straight runs, pipe internal condition and entrained gas, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clamp-on versions avoid pipe work, minimising shutdown in revamps, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Ultrasonic flowmeter — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was transit-time ultrasonic measurement of liquid or gas flow.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking straight runs, pipe internal condition and entrained gas.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around checking straight runs, pipe internal condition and entrained gas, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clamp-on versions avoid pipe work, minimising shutdown in revamps, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Ultrasonic flowmeter — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Ultrasonic flowmeter, focusing on transit-time ultrasonic measurement of liquid or gas flow.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Ultrasonic flowmeter specification must therefore cover checking straight runs, pipe internal condition and entrained gas.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on checking straight runs, pipe internal condition and entrained gas, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clamp-on versions avoid pipe work, minimising shutdown in revamps, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Ultrasonic flowmeter — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Ultrasonic flowmeter; the focus is transit-time ultrasonic measurement of liquid or gas flow.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking straight runs, pipe internal condition and entrained gas.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on checking straight runs, pipe internal condition and entrained gas, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clamp-on versions avoid pipe work, minimising shutdown in revamps, which cut the workload on the site maintenance team.