Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FDU90 Prosonic S

FDU90 Prosonic S
Prosonic S FDU90
Configurable Models 20 models
The FDU90 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in liquids 3m (9.8ft), solids 1.2m (3.9ft).
Compare

Continuous / Liquids

Measuring Principle Ultrasonic
Characteristic / Application Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
Specialities Floating protection tube
Supply / Communication 4-wire (HART, PROFIBUS DP)
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process pressure / max. overpressure limit 0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
Main wetted parts PVDF (IP68 / NEMA6P)
Process connection Front side thread:
G / NPT 1 1/2"
Rear side thread:
G / NPT 1"
Ceiling mounting
Blocking distance 0.07 m (0.23 ft)
Max. measurement distance Liquids: 3 m (9.8 ft),
Solids: 1.2 m (3.9 ft)
Communication Transmitter:
4 ... 20 mA HART
PROFIBUS DP
Certificates / Approvals ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex
Options Second 4...20mA output
Components Transmitter:
FMU90, FMU95
Application limits Foam / high turbulence possible:
FDU92
Flange-flush assembly:
FDU91F
For tank farms scanner:
FMU95

Continuous / Solids

Measuring Principle Ultrasonic
Characteristic / Application Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
Supply / Communication 4-wire (HART, PROFIBUS DP)
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process pressure / max. overpressure limit 0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
Main wetted parts PVDF (IP68 / NEMA6P)
Process connection Front side thread:
G / NPT 1 1/2"
Rear side thread:
G / NPT 1"
Ceiling mounting
Blocking distance 0.07 m (0.23 ft)
Max. measurement distance Liquids: 3 m (9.8 ft),
Solids: 1.2 m (3.9 ft)
Communication Transmitter:
4 ... 20 mA HART
PROFIBUS DP
Certificates / Approvals ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex
Options Second 4...20mA output
Components Transmitter:
FMU90

Liquids

Measuring Principle Ultrasonic
Product headline Version with separate transmitter in field housing or top hat rail housing
Cost effective solution for open channel flow measurement in water / wastewater plants
Max. measurement error Accuracy:
distance measurement: +/- 2mm + 0.17%
Measuring range Up to 3 m / 9.8 ft
Max. process pressure 0.4 bar...4 bar
(10 psi...58 psi)
Medium temperature range -40 °C ... 80 °C
(-40 °F ... 176 °F)
Degree of protection IP68
Display/Operation Transmitter FMU90
Outputs Transmitter:
4 ... 20 mA HART
PROFIBUS DP
Inputs Transmitter FMU90
Digital communication HART, PROFIBUS DP
Hazardous area approvals ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex

The FDU90 ultrasonic sensor is suitable for continuous, non-contact level measurement of liquids and pastes, is maintenance-free and can also be used for flow measurement in open channels and measuring weirs. Measured values are unaffected by dielectric constant, density or humidity, and the sensor self-cleaning function eliminates the influence of medium adhesion on measurement. Suitable for explosive hazardous areas; maximum measuring range: liquids 3m.

 

Advantages

Built-in temperature sensor for time-of-flight calibration; precise measurement even with temperature changes

Hermetically welded PVDF sensor for the highest level of corrosion-resistant measurement applications

Suitable for harsh climatic conditions; sensor and transmitter can be installed separately with a maximum distance of 300m

Sensor self-cleaning function reduces adhesion formation

Built-in automatic sensor detection for convenient commissioning with the FMU90/FMU95 transmitter

Degree of protection IP68

Sensor with heating function (optional) prevents icing and ensures reliable measured values

 

Areas of application

Suitable for continuous, non-contact level measurement of liquids and pastes; flow measurement in open channels and measuring weirs. Maximum measuring range: liquids 3m (9.8ft).

Spare Parts & Accessories 14

14 spare parts · click to collapse
Order codeDescription
71395801FTI26 Lock NutMounting aid. Material: plastic PA. Wrench size: 41mm. Usage: FDU90/FDU91/FDU92, FMR10/FMR20, FTC968 AC, FTI26.Details
71452323Wall-mounted sensor bracket, 316LMaterial: 316L. Usage: FMR10B, FMR20B, FMR30B, FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMU30, FMU40, FMU41.Details
71452315Sensor bracket 500 mm, 316LMounting 1" sensor. Material: 316L. Usage: FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMR10B, FMR20B.Details
71452316Sensor bracket 1000mm, 316L, US-sensorMounting 1" sensor. Material: 316L. Usage: FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMR10B, FMR20B.Details
71093130mounting bracketMaterial: 316L. Usage: FDU90/FDU91/FDU91F/FDU92/FDU93/FDU95, FMR10, FMR20.Details
71325079adjustable mounting bracket适合FDU90, FMR10, FMR20.Details
71452327Bracket 700 mm, 316LPipe diameter: 1". Material: 316L. Usage: FMR10B, FMR20B, FMR30B, FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMU30, FMU40, FMU41.Details
71452326Bracket 1400mm, 316LPipe diameter: 1". Material: 316L. Usage: FMR10B, FMR20B, FMR30B, FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FMR10, FMR20, FMU30, FMU40, FMU41.Details
52025686Sunshade材质:PVDF 适合FDU90/FDU91, FMR10, FMR20.Details
71027742extension cableLiYCY/CUL 2x(0,75) to connect to FMU90/FMU95 Price per meterDetails
71027746extension cableLIYY/CUL 2x(0,75)D+2x0,75 to connect to FMU90/FMU95 Price per meterDetails
71091216Overflow Protection Pipe FDU90Thread ISO228 G1-1/2. Usage: FDU90, FMR10B, FMR20B.Details
FAX50-Threaded Flange FAX50Usage: FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57, FMR20, FMR20B, FMR30B, FMR60, FMR67, FMR60B, FMR66B, FMU30, FMU40, FMU41, FMU42, FMU44, FDU90, FDU91, FDU92, FDU93, FDU95, FTI51, FTI52, FTI55, FTI56, FTI77.Enquire
FAU40-Mounting Accessories TTP FAU40Aiming ultrasonic sensors for optimum echo signal in separate version. Usage: FDU-sensors. Also for use in ATEX II 1/2D.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play

Source:Endress+Hauserwebsite public information

36 models · click to collapse
All documents for this model
10 documents · click to expand
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

Prosonic S FDU90/91/91F/92/93/95/96 技术资料 Chinese

Rev. 1512 32 pages
Preview
TI

TI Prosonic S FDU90 Chinese

Rev. 0326 24 pages
Preview
TI

TI 文丘里水槽QV302...QV316 Chinese

Rev. 0224 12 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

Prosonic S FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95 English

Rev. 1818 44 pages
Preview
TI

Flange DIN - EN -ASME - JIS Successor: TI00426F English

Rev. 1310 24 pages
Preview
TI

TI Prosonic S FDU90 English

Rev. 0326 28 pages
Preview
TI

TI Khafagi-Venturi QV302 to QV316 English

Rev. 0224 12 pages
Preview
TI

Flange DIN - EN -ASME - JIS English

Rev. 0110 24 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · ultrasound — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from ultrasound , focusing on ultrasonic liquid level measurement or interface detection.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The ultrasound specification must therefore cover sizing range against dead zone, mounting height and medium temperature.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on sizing range against dead zone, mounting height and medium temperature, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — retrofit without touching the tank, with short installation time, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · ultrasound — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is ultrasound ; the focus is ultrasonic liquid level measurement or interface detection.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with sizing range against dead zone, mounting height and medium temperature.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on sizing range against dead zone, mounting height and medium temperature, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means retrofit without touching the tank, with short installation time, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · ultrasound — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on ultrasound and the core task is ultrasonic liquid level measurement or interface detection.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So ultrasound cannot be specified generically — it calls for sizing range against dead zone, mounting height and medium temperature.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves sizing range against dead zone, mounting height and medium temperature, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is retrofit without touching the tank, with short installation time.

Power & Energy

Power & Energy · ultrasound — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted ultrasound properly configured on the existing plant, with the aim of ultrasonic liquid level measurement or interface detection.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the ultrasound configuration has to involve sizing range against dead zone, mounting height and medium temperature.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant sizing range against dead zone, mounting height and medium temperature, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is retrofit without touching the tank, with short installation time, and the readings are now used for process tuning.