FMU95 Prosonic S

FMU95 Prosonic S
Prosonic S FMU95
Prosonic FMU95 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids.
Compare

Continuous / Liquids

Measuring Principle Ultrasonic
Characteristic / Application Separated version with Field housing or top hat rail housing for control cabinet instrumentation, 5 or 10 channel version
Specialities Protection Class IP 66 / NEMA 4x
automatic sensor recognition of FDU9x sensors
Supply / Communication 90 ... 253 VAC
10.5 ... 32 VDC
Profibus DP
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 60 °C
(-40 °F ... 140 °F)
Communication Profibus DP
Certificates / Approvals ATEX, CSA
Options Illuminated display, 6 line graphic display with country specific menu guidance, on-site diagnosis with envelope curve on display
Components Sensors FDU9x

Continuous / Solids

Measuring Principle Ultrasonic
Characteristic / Application Separated version with Field housing or top hat rail housing for control cabinet instrumentation, 5 or 10 channel version
Specialities Protection Class IP 66 / NEMA 4x
automatic sensor recognition of FDU9x sensors
Supply / Communication 90 ... 253 VAC
10.5 ... 32 VDC
Profibus DP
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 60 °C
(-40 °F ... 140 °F)
Communication Profibus DP
Certificates / Approvals ATEX, CSA
Options Illuminated display, 6 line graphic display with country specific menu guidance
Components Sensors FDU9x

The FMU95 separate transmitter can be installed in the field or on a DIN rail in an instrument cabinet. It is suitable for continuous, non-contact level measurement of liquids, pastes, sludge, powders and coarse bulk solids.

Benefits

Simple menu-guided on-site operation with a six-line plain text display, available in 15 languages

On-site envelope curve display for fast and simple instrument fault diagnosis

The FieldCare operating software allows convenient remote operation, fault diagnosis and measuring point documentation

Time-of-flight calibration via built-in or external temperature sensor

Linearization function (up to 32 points) freely configurable

PROFIBUS DP system integration, processing up to 20 measured values

Automatic FDU9x sensor recognition

Application areas

With 5 to 10 sensors for continuous, non-contact level measurement of liquids, pastes, sludge, powders and bulk solids; measuring range up to 45 m (depending on sensor and medium); average or total calculation

Spare Parts & Accessories 29

29 spare parts · click to collapse
Order codeDescription
52025713DIN rail mounting housingBasic version consists of: frame, 2 side frame and locking Din Rail Prosonic S "For E+H Service only"Details
52025702Circuit Board Mounting Bracketwith Torx screw, field housing Prosonic SDetails
52025712blind coverMaterial: plastics Prosonic SDetails
71037237CoverMaterial: plastics. Blind cover, hinge. Usage: FMU95.Details
71037238Housing with displayMaterial: plastics. Display cover, hinge. Usage: FMU95.Details
71037239Wide PanelDisplay module. Material: plastics. DIN Rail mounting. Usage: FMU95.Details
71037240Wide PanelMaterial: plastics. DIN Rail mounting. Usage: FMU95.Details
71024576Field-mount housing screwconsists of: 2x hinge 4x screwDetails
71024578screw setProsonic SDetails
52025718Output boardfor version 3 relay FMU90 1 relay included in electronics FMU90X Prosonic SDetails
52025719Output boardfor version 6 relay FMU90 1 relay included in electronics FMU90X Prosonic S FMU90Details
52025721cableConnection cable between display and basic electronics field housing Prosonic S FMU90Details
52025722cableConnection cable between display and basic electronics DIN Rail mounting Prosonic S FMU90Details
FMU95X-Basic version electronics FMU95XElectronics basic version FMU95XEnquire
71035385PC boardConnection FDU sensors 1...5. Usage: FMU95.Details
71035387PC boardConnection FDU sensors 6...10. Usage: FMU95.Details
52025720Output boardPC board PROFIBUS DP FMU90Details
71024577PCB Link Assemblyconsists of: 1x PCB connector power supply 2x PCB connector relay 2x PCB connector current output/synchronisation 1x PCB connector sensor output Prosonic SDetails
71354876Power boardUsage: FMU90/FMU95, NXA20, NXA820/NXA821/NXA822.Details
71038663Remote DisplayPanel mounting. Connection cable 3m. Usage: FMU95.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play

Source: public information from the Endress+Hauser website

All documents for this model
11 documents · click to expand
BA

BA Prosonic S FMU95 PROFIBUS DP Chinese

PROFIBUS-DP Rev. 1725 76 pages
Preview
BA

BA Prosonic S FMU95 PROFIBUS DP English

PROFIBUS-DP Rev. 1725 80 pages
Preview
BA

Prosonic S FMU95 English

Rev. 1312 86 pages
Preview
BA

Prosonic S FMU95 English

Rev. 1312 76 pages
Preview
BA

Technical Information Prosonic S FMU95 English

Rev. 0709 112 pages
Preview
BA

Description of Instrument Functions Prosonic S FMU95 English

Rev. 0709 76 pages
Preview
BA

Prosonic S FMU95 Slot Index Tables for PROFIBUS DP English

PROFIBUS-DP Rev. 0407 86 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

TI Prosonic S FMU95 Chinese

Rev. 2025 28 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

TI Prosonic S FMU95 English

Rev. 2025 28 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · ultrasound — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from ultrasound , focusing on ultrasonic liquid level measurement or interface detection.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The ultrasound specification must therefore cover sizing range against dead zone, mounting height and medium temperature.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on sizing range against dead zone, mounting height and medium temperature, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — retrofit without touching the tank, with short installation time, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · ultrasound — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is ultrasound ; the focus is ultrasonic liquid level measurement or interface detection.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with sizing range against dead zone, mounting height and medium temperature.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on sizing range against dead zone, mounting height and medium temperature, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means retrofit without touching the tank, with short installation time, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · ultrasound — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on ultrasound and the core task is ultrasonic liquid level measurement or interface detection.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So ultrasound cannot be specified generically — it calls for sizing range against dead zone, mounting height and medium temperature.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves sizing range against dead zone, mounting height and medium temperature, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is retrofit without touching the tank, with short installation time.

Power & Energy

Power & Energy · ultrasound — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted ultrasound properly configured on the existing plant, with the aim of ultrasonic liquid level measurement or interface detection.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the ultrasound configuration has to involve sizing range against dead zone, mounting height and medium temperature.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant sizing range against dead zone, mounting height and medium temperature, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is retrofit without touching the tank, with short installation time, and the readings are now used for process tuning.