Configurable Models 20 models
Prosonic FMU90 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids. Also the flow measurement in open channels and weirs is possible as the simultaneous measurement of level and flow in a storm water overflow basin with only 1 sensor. Up to 6 relays for tendency alarm, flow pulse output or backwater/sludge alarm, 1 or 2 channel version.
Compare

Continuous / Liquids

Measuring Principle Ultrasonic
Characteristic / Application Separated version with Field housing or top hat rail housing for control cabinet instrumentation, up to 6 relays for pump / rake / limit control, 1 or 2 channel version
Specialities Protection Class IP 66 / NEMA 4x
automatic sensor recognition of FDU9x sensors
option: flow measurement for open channel and weirs or additional pump control functions
Supply / Communication 90 ... 253 VAC
10.5 ... 32 VDC
up to 2x 4...20mA HART
Profibus DP
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 60 °C
(-40 °F ... 140 °F)
Communication up to 2x 4 ... 20 mA HART
Profibus DP
Certificates / Approvals ATEX, CSA
Options Illuminated display, 6 line graphic display with country specific menu guidance, on-site diagnosis with envelope curve on display
Components Sensors FDU9x

Continuous / Solids

Measuring Principle Ultrasonic
Characteristic / Application Separated version with Field housing or top hat rail housing for control cabinet instrumentation, up to 6 relays for limit control, 1 or 2 channel version
Specialities Protection Class IP 66 / NEMA 4x
automatic sensor recognition of FDU9x sensors
Supply / Communication 90 ... 253 VAC
10.5 ... 32 VDC
up to 2x 4...20mA HART
Profibus DP
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 60 °C
(-4 °F ... 140 °F)
Communication up to 2x 4 ... 20 mA HART
Profibus DP
Certificates / Approvals ATEX, CSA
Options Illuminated display, 6 line graphic display with country specific menu guidance, on-site diagnosis with envelope curve on display
Components Sensors FDU9x

Liquids

Measuring Principle Ultrasonic
Product headline Separated version with field housing or top hat rail housing for control cabinet instrumentation, up to 6 relays for tendency alarm, flow pulse output or backwater / sludge alarm, 1 or 2 channel version
Sensor features pre-programed flow curves for typical open channel measurement
Degree of protection IP66 (Fieldhousing)
IP20 (top hat rail housing)
Display/Operation Illuminated display, 6 line graphic display with country specific menu guidance, on-site diagnosis with envelope curve on display
Outputs 4...20mA HART
Optional:
second 4...20 mA output (e.g. for 2 times flow measurement
1 relay (standard)
Optional:
3 or 6 relays
Inputs up to 2 FDU9x sensors
Digital communication HART, Profibus DP
Hazardous area approvals FMU allowed to operate FDU9x in Ex-zone

The Prosonic FMU90 can be installed in the field or on a DIN rail in an instrument cabinet. It is suitable for continuous, non-contact level measurement of liquids, pastes, sludge, powders and coarse bulk solids. It can also be used for flow measurement in open channels and weirs; with a single sensor it can simultaneously measure the level and flow of stormwater overflow basins. Up to 6 relays can trigger trend alarms, flow pulse output alarms or backwater/sludge alarms, with single-channel or dual-channel versions available.

 

Benefits

Simple menu-guided on-site operation with a six-line plain text display, available in 15 languages

On-site envelope curve display for simple instrument fault diagnosis

The FieldCare operating software allows convenient remote operation, fault diagnosis and measuring point documentation

Time-of-flight calibration via built-in or external temperature sensor

Linearization function (up to 32 points) converts the measured value into length, volume or flow in any unit

Online calculation of channel/weir flow based on built-in flow curves

Automatic FDU9x sensor recognition function

 

Application areas

Level measurement: with 1 to 2 sensors for level measurement of liquids and bulk solids; measuring range up to 45 m; limit detection; pump control systems; target control systems; optional: additional pump control function; calculation: average, difference, total; Flow measurement: with 1 to 2 sensors for flow measurement in open channels and measuring weirs; return flow measurement or sludge monitoring; up to 3 totalizers and 3 counters; counter or time pulse output for external control units

 

Commonly used model:FMU90-R11CA111AA3A

Spare Parts & Accessories 35

35 spare parts · click to collapse
Order codeDescription
52025713DIN rail mounting housingBasic version consists of: frame, 2 side frame and locking Din Rail Prosonic S "For E+H Service only"Details
52025695Mounting plateMaterial: plastics Prosonic SDetails
52025702Circuit Board Mounting Bracketwith Torx screw, field housing Prosonic SDetails
52025712blind coverMaterial: plastics Prosonic SDetails
52025699Housing with displayMaterial: plastics Display cover with hinge Prosonic SDetails
52025700CoverMaterial: plastics Blind cover with hinge Prosonic SDetails
52025705front panelMaterial: plastics Basic version DIN rail Prosonic SDetails
52025708front panelMaterial: plastics DIN Rail, extended Prosonic SDetails
52025703with display panelwith display Material: plastics Basic version DIN Rail Prosonic SDetails
52025710with display panelwith display Material: plastics DIN Rail, extended Prosonic SDetails
71024576Field-mount housing screwconsists of: 2x hinge 4x screwDetails
71024578screw setProsonic SDetails
52025711panel with blind coverMaterial: plastics DIN Rail maximum version Prosonic SDetails
52025721cableConnection cable between display and basic electronics field housing Prosonic S FMU90Details
52025722cableConnection cable between display and basic electronics DIN Rail mounting Prosonic S FMU90Details
FMU90X-FMU90X basic version electronic insertElectronics basic version FMU90XEnquire
52025714Output boardConnection 2 sensor FDU Prosonic S FMU90Details
52025715Output BoardProsonic S FMU90Details
52025716Output BoardProsonic S FMU90Details
52025718Output boardfor version 3 relay FMU90 1 relay included in electronics FMU90X Prosonic SDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play
466 models · click to collapse
All documents for this model
12 documents · click to expand
BA

BA Prosonic S FMU90 HART Chinese

HART Rev. 1725 100 pages
Preview
BA

BA Prosonic S FMU90 HART Chinese

HART Rev. 1725 100 pages
Preview
BA

BA Prosonic S FMU90 PROFIBUS DP Chinese

PROFIBUS-DP Rev. 1725 102 pages
Preview
BA

BA Prosonic S FMU90 PROFIBUS DP Chinese

PROFIBUS-DP Rev. 1725 100 pages
Preview
BA

BA Prosonic S FMU90 HART English

HART Rev. 1725 104 pages
Preview
BA

BA Prosonic S FMU90 HART English

HART Rev. 1725 108 pages
Preview
BA

BA Prosonic S FMU90 PROFIBUS DP English

PROFIBUS-DP Rev. 1725 110 pages
Preview
BA

BA Prosonic S FMU90 PROFIBUS DP English

PROFIBUS-DP Rev. 1725 110 pages
Preview
BA

Prosonic S FMU90 English

Rev. 1312 214 pages
Preview
BA

Prosonic S FMU90 English

Rev. 1312 160 pages
Preview
BA

Prosonic S FMU90 Description of Instrument Functions English

Rev. 0709 216 pages
Preview
BA

Prosonic S FMU90 Operating Instructions Flow HART English

HART Rev. 0709 168 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · ultrasound — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from ultrasound , focusing on ultrasonic liquid level measurement or interface detection.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The ultrasound specification must therefore cover sizing range against dead zone, mounting height and medium temperature.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on sizing range against dead zone, mounting height and medium temperature, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — retrofit without touching the tank, with short installation time, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · ultrasound — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is ultrasound ; the focus is ultrasonic liquid level measurement or interface detection.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with sizing range against dead zone, mounting height and medium temperature.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on sizing range against dead zone, mounting height and medium temperature, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means retrofit without touching the tank, with short installation time, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · ultrasound — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on ultrasound and the core task is ultrasonic liquid level measurement or interface detection.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So ultrasound cannot be specified generically — it calls for sizing range against dead zone, mounting height and medium temperature.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves sizing range against dead zone, mounting height and medium temperature, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is retrofit without touching the tank, with short installation time.

Power & Energy

Power & Energy · ultrasound — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted ultrasound properly configured on the existing plant, with the aim of ultrasonic liquid level measurement or interface detection.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the ultrasound configuration has to involve sizing range against dead zone, mounting height and medium temperature.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant sizing range against dead zone, mounting height and medium temperature, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is retrofit without touching the tank, with short installation time, and the readings are now used for process tuning.