FMU42 Prosonic M

FMU42 Prosonic M
Prosonic M FMU42
Configurable Models 20 models
The Prosonic FMU42 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.
Compare

Continuous / Liquids

Measuring Principle Ultrasonic
Characteristic / Application Compact ultrasonic transmitter
Supply / Communication 2-wire HART
Accuracy +/- 4 mm or +/- 0,2 % of set measuring range
Ambient temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process pressure / max. overpressure limit 0.7 bar ... 2.5 bar abs
(10 psi ... 36 psi)
Main wetted parts PVDF
Process connection Flange
DN80, ASME 3", JIS 10K 80
DN100,ASME 4", JIS 10K 100
Mounting bracket
Blocking distance 0.4 m (1.3 ft)
Max. measurement distance Liquids: 10 m (33 ft),
Solids: 5 m (16 ft)
Communication 4...20 mA HART
Certificates / Approvals ATEX, FM, CSA, IEC, INMETRO, NEPSI
Application limits Foam / high turbulence possible:
FMU44/FDU92
Fast filling and discharging
rate:
FMU90 + FDU9x
Level limit detection
FMU90 + FDU9x

Continuous / Solids

Measuring Principle Ultrasonic
Characteristic / Application Compact ultrasonic transmitter
Supply / Communication 2-wire HART
Accuracy +/- 4 mm or +/- 0,2 % of set measuring range
Ambient temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process pressure / max. overpressure limit 0.7 bar ... 2.5 bar abs
(10 psi ... 36 psi)
Main wetted parts PVDF
Process connection Flange
DN80, ASME 3", JIS 10K 80
DN100,ASME 4", JIS 10K 100
Mounting bracket
Blocking distance 0.4 m (1.3 ft)
Max. measurement distance Liquids: 10 m (33 ft),
Solids: 5 m (16 ft)
Communication 4...20 mA HART
Certificates / Approvals ATEX, FM, CSA, IEC, INMETRO, NEPSI
Application limits Take notice of range diagram

The Prosonic FMU42 is used for non-contact level measurement of liquids, pastes and coarse bulk solids as well as for flow measurement in open channels or weirs. The two-wire or four-wire compact transmitter can be used in demanding conditions such as storage tanks, agitators, silos and conveyor belts. On-site envelope curve display enables simple instrument fault diagnosis. The linearization function (up to 32 points) converts the measured value into length, volume or flow in any unit.

Benefits

  • Four-line plain text display with menu-guided on-site operation for fast, simple instrument commissioning, available in 7 languages

  • On-site envelope curve display for simple instrument fault diagnosis

  • The FieldCare operating software allows convenient remote operation, fault diagnosis and measuring point documentation

  • Suitable for hazardous areas (gas Ex, dust Ex)

  • Linearization function (up to 32 points) converts the measured value into length, volume or flow in any unit

  • Built-in temperature sensor for automatic correction of the temperature-dependent speed of sound

  • Optional remote display and operation (maximum installation distance from the transmitter of 20 m (66 ft))

Application areas

For continuous, non-contact level measurement of liquids, pastes, sludge and bulk solids; flow measurement in open channels and measuring weirs; system integration: HART (standard), 4…20 mA, PROFIBUS PA, FOUNDATION Fieldbus; maximum measuring range: liquids: 5 m, solids: 2 m. Other measuring ranges: FMU41: liquids 8 m, solids: 3.5 m; FMU42: liquids: 10 m, solids: 5 m; FMU43: liquids: 15 m, solids: 7 m; FMU44: liquids 20 m, solids: 10 m

Commonly used model: FMU42-APB2A22A

 

Spare Parts & Accessories 48

48 spare parts · click to collapse
Order codeDescription
52020763plug connectorCerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
535720-9020Set of screws housing F12/T12/F23Consists of: 1x stop screw M5x10. 1x retaining screw M8x10. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.Details
52010526Seal kitconsists of: 1x O-ring 113.9x3.53 EPDM 1x O-ring 72.0x3.0 EPDM 1x O-ring 49.21x3.53 EPDM 1x flat gasket 47x58x2 EPDM 1x flat gasket 59x68x2.5 EPDM 2x O-ring 17,0x2,0 EPDMDetails
52006026Terminal Chamber CoverHood for terminal compartment Micropilot M, Prosonic M, Levelflex MDetails
52019062Terminal Chamber CoverHood for terminal compartment for separate display Micropilot M, Prosonic M, Levelflex MDetails
52005936Aluminum coverMaterial: Aluminium for operating + display module VU331 and housing F12/T12 Micropilot M/S, Prosonic M, Levelflex MDetails
517391-0011Cover F12/T12 Alu, coated, gasketMaterial: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.Details
518710-0020Cover T3/T12 Alu, coated, gasketMaterial: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231,FMR240/FMR244/ FMR245, FMR250, FMR530/FMR531/FMR532/ FMR533, FMR540, FMU40/FMU41/FMU42.Details
52005643maskcable compartment, electronics side Micropilot M/S, Prosonic M, Levelflex MDetails
71092209O-ringUsage: cover T12/F12/F23.Details
52006197Terminal modulewith cable connection for housing F12 Micropilot M, Levelflex M, Prosonic MDetails
52012156Terminal modulePROFIBUS PA, FOUNDATION Fieldbus Micropilot II/M, Prosonic M, Levelflex MDetails
52013304Power Supplyfor electronics 4-wire Levelflex M, Prosonic MDetails
52013305Power Supplyfor electronics 4-wire Levelflex M, Prosonic MDetails
71396869Power supply module 90-250VAC (F12) v2, non-explosion-proofPower supply, HART, version 2. Only for "non ex area". Usage: FMU40/FMU41/FMU42/FMU43/FMU44.Details
52015585Power Supplyfor electronics 4-wire Levelflex M, Prosonic MDetails
52015586Power Supplyfor electronics 4-wire Levelflex M, Prosonic MDetails
52013302Terminal modulefor housing T12, Levelflex M, Prosonic M, Micropilot MDetails
52013303Terminal module2-wire, PROFIBUS PA/FOUNDATION Fieldbus Ex d limiter, for housing T12 Levelflex M, Micropilot M, Prosonic MDetails
52018949Terminal module4-pole, 2-wire for Aluminium T12 housing OVP = overvoltage protection Levelflex M, Prosonic M, Micropilot MDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play

Source: public information from the Endress+Hauser website

42 models · click to collapse
All documents for this model
12 documents · click to expand
BA

操作手册 Prosonic M FMU40/41/42/43/44 Chinese

Rev. 1312 76 pages
Preview
BA

Prosonic M FMU42 HART Chinese

HART Rev. 0122 52 pages
Preview
BA

Prosonic M FMU40/41/42/43/44 English

Rev. 1312 76 pages
Preview
BA

Prosonic M FMU40/41/42/43/44 English

Rev. 1312 84 pages
Preview
BA

Prosonic M FMU40/41/42/43/44 English

Rev. 1312 92 pages
Preview
BA

Prosonic M FMU40/41/42/43/44 English

Rev. 1312 100 pages
Preview
BA

Prosonic M FMU 40/41/42/43 4-20mA HART, PA, FF Description of Instrument Functions English

HART Rev. 0907 88 pages
Preview
BA

Prosonic M FMU42 HART English

HART Rev. 0122 52 pages
Preview
BA

Prosonic M FMU 40/41/42/43 Foundation Fieldbus Operating Instructions English

FOUNDATION-Fieldbus Rev. 0109 112 pages
Preview
BA

Prosonic M FMU 40/41/42/43 4-20 mA HART Operating Instructions English

HART Rev. 0109 80 pages
Preview
BA

Prosonic M FMU 40/41/43 PROFIBUS-PA Operating Instructions English

PROFIBUS-PA Rev. 0109 92 pages
Preview
BA

Prosonic M FMU 40/41/42/43 Foundation Fieldbus Operating Instructions English

FOUNDATION-Fieldbus 84 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · ultrasound — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from ultrasound , focusing on ultrasonic liquid level measurement or interface detection.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The ultrasound specification must therefore cover sizing range against dead zone, mounting height and medium temperature.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on sizing range against dead zone, mounting height and medium temperature, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — retrofit without touching the tank, with short installation time, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · ultrasound — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is ultrasound ; the focus is ultrasonic liquid level measurement or interface detection.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with sizing range against dead zone, mounting height and medium temperature.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on sizing range against dead zone, mounting height and medium temperature, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means retrofit without touching the tank, with short installation time, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · ultrasound — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on ultrasound and the core task is ultrasonic liquid level measurement or interface detection.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So ultrasound cannot be specified generically — it calls for sizing range against dead zone, mounting height and medium temperature.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves sizing range against dead zone, mounting height and medium temperature, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is retrofit without touching the tank, with short installation time.

Power & Energy

Power & Energy · ultrasound — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted ultrasound properly configured on the existing plant, with the aim of ultrasonic liquid level measurement or interface detection.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the ultrasound configuration has to involve sizing range against dead zone, mounting height and medium temperature.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant sizing range against dead zone, mounting height and medium temperature, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is retrofit without touching the tank, with short installation time, and the readings are now used for process tuning.