Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

FDU92 超声波液位计探头

FDU92 超声波液位计探头

Prosonic S FDU92

Configurable Models 20 models
The FDU92 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in liquids 20m (65ft), solids 10m (33ft).
Compare

Continuous / Liquids

Measuring Principle Ultrasonic
Characteristic / Application Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter
Supply / Communication 4-wire (HART, PROFIBUS DP)
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 95 °C
(-40 °F ... 203 °F)
Process temperature -40 °C ... 95 °C
(-40 °F ... 203 °F)
Process pressure / max. overpressure limit 0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
Main wetted parts PVDF (fully welded IP68 / NEMA 6P)
Process connection G / NPT 1"
Blocking distance 0.4 m (1.3 ft)
Max. measurement distance Liquids: 20 m (65 ft),
Solids: 10 m (33 ft)
Communication Transmitter:
4 ... 20 mA HART
PROFIBUS DP
Certificates / Approvals ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex
Options Second 4...20 mA output
Components Transmitter:
FMU90, FMU95
Application limits For tank farms scanner:
FMU95

Continuous / Solids

Measuring Principle Ultrasonic
Characteristic / Application Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
Supply / Communication 4-wire (HART, PROFIBUS DP)
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 95 °C
(-40 °F ... 203 °F)
Process temperature -40 °C ... 95 °C
(-40 °F ... 203 °F)
Process pressure / max. overpressure limit 0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
Main wetted parts PVDF (fully welded IP68 / NEMA 6P)
Process connection G / NPT 1"
Blocking distance 0.4 m (1.3 ft)
Max. measurement distance Liquids: 20 m (65 ft),
Solids: 10 m (33 ft)
Communication Transmitter:
4 ... 20 mA HART
PROFIBUS DP
Certificates / Approvals ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex
Options Second 4...20mA output
Components Transmitter:
FMU90

Liquids

Measuring Principle Ultrasonic
Product headline Ultrasonic sensor for level and open channel flow measurement.
For applications requiring separate level / open channel flow measurement system.
Max. measurement error accuracy:
distance measurement: +/- 2mm + 0.17%
Measuring range Up to 20m / 65ft
Max. process pressure 0.4 bar...4 bar
(10 psi...58 psi)
Medium temperature range -40...95°C
(-40...203°F)
Degree of protection IP68
Display/Operation Transmitter FMU90
Outputs Transmitter:
4...20mA HART
PROFIBUS DP
Inputs Transmitter FMU90
Digital communication HART, PROFIBUS DP
Hazardous area approvals ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex

The FDU92 ultrasonic sensor is suitable for continuous, non-contact level measurement of liquids, pastes, sludge, powders and coarse bulk solids, is maintenance-free and can also be used for flow measurement in open channels and measuring weirs. Measured values are unaffected by dielectric constant, density or humidity, and the sensor self-cleaning function eliminates the influence of medium adhesion on measurement. Suitable for explosive hazardous areas; maximum measuring range: liquids 20m (65ft), solids 10m (33ft).

 

Advantages

Built-in temperature sensor for time-of-flight calibration; precise measurement even with temperature changes

Hermetically welded PVDF sensor for the highest level of corrosion-resistant measurement applications

Suitable for harsh climatic conditions; sensor and transmitter can be installed separately with a maximum distance of 300m

Sensor self-cleaning function reduces adhesion formation

Built-in automatic sensor detection for convenient commissioning with the FMU90/FMU95 level transmitter

Degree of protection IP68

Dust-Ex and gas-Ex approvals (ATEX, FM, CSA)

 

Areas of application

Suitable for continuous, non-contact level measurement of liquids, pastes, sludge, powders and coarse bulk solids; flow measurement in open channels and measuring weirs. Maximum measuring range: liquids 20m, solids 10m; suitable for explosive hazardous areas; other measuring ranges: FDU91/91F: liquids 10m, solids 5m; FDU93: liquids 25m, solids 15m; FDU95: solids 45m; FDU96: solids 70m

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

 

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

   

Measuring principle video

Source:Endress+Hauserwebsite public information

Model Name
FDU92-RG1A 超声波液位计探头
FDU92-RG2A 超声波液位计探头
FDU92-AG2A 超声波液位计探头
FDU92-RG6A 超声波液位计探头
FDU92-RN6A 超声波液位计探头
FDU92-JG2A 超声波液位计探头
FDU92-JN6A 超声波液位计探头
FDU92-AN1A 超声波液位计探头
FDU92-RN5A 超声波液位计探头
FDU92-AN2A 超声波液位计探头
FDU92-LN1A 超声波液位计探头
FDU92-AG3A 超声波液位计探头
FDU92-LN2A 超声波液位计探头
FDU92-JN3A 超声波液位计探头
FDU92-LN3A 超声波液位计探头
FDU92-JG3A 超声波液位计探头
FDU92-RG3A 超声波液位计探头
FDU92-AN5A 超声波液位计探头
FDU92-LN4A 超声波液位计探头
FDU92-JN2A 超声波液位计探头
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Ultrasonic Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Ultrasonic.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Ultrasonic Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Ultrasonic.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Ultrasonic Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Ultrasonic.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Ultrasonic Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Ultrasonic.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.