Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FMI52 Liquicap M

FMI52 Liquicap M
Liquicap M FMI52
Liquicap FMI52 is a reliable fully insulated rope probe for continuous level monitoring in liquids, particularly in small tanks, build-up forming media and extremely high temperatures - especially for large measuring ranges. The measurement is independent of the dielectric constant (dc). Used in conjunction with Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.
Compare

Continuous / Liquids

Measuring Principle Capacitive
Characteristic / Application Fully insulated rope probe, for standard and extreme process conditions (temperature, pressure)
Interface measurement Interfaces liquid / liquid also with emulsion layers
Specialities Inactive length
Factory calibrated
short response time by change of value
Supply / Communication 12-36V DC HART
PFM
Accuracy repeatablity 0,1%
Linearity error for conductive liquids <0.5%
Ambient temperature -50°C...+70°C
-58°F...+158°F
Process temperature -80°C...200°C
-112°F...392°F
Process pressure / max. overpressure limit Vacuum ... 100 bar
(Vaccum ... 1450 psi)
Main wetted parts Insulation material: FEP,PFA
316L
Process connection G 3/4, G 1, G1 1/2 /NPT 3/4", NPT 1, NPT1 1/2"
Flange from DN25.../ASME 1".../JIS...
Process connection hygienic Tri-Clamp ISO02852 gap free plated
Dairy coupling
Flush-mounted seal
Sensor length Total length: 6m (20ft)
Inactive length: max. 2m (7ft)
Max. measurement distance 0.42 m ... 10.0 m
(1.38 ft ... 33 ft)
Communication 4...20mA HART
PFM
Certificates / Approvals ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC
Safety approvals SIL
Design approvals EN 10204-3.1
NACE MR0175
Hygienic approvals EHEDG
Marine approval GL/ ABS/ DNV
Options Separate housing
gas-tight probe seal
Application limits Changing, non-conductive
media, conductivity
< 100 μS/cm
Notice the pressure and temperature derating

The Liquicap FMI52 reliable, fully insulated probe can be used for continuous liquid level measurement, especially in small tanks, media with buildup and extremely high temperatures, and is the best choice for large measuring ranges. Measurement is independent of the DK value (dielectric constant). Used together with the Fieldgate FXA320 (remote measured value access via Internet technology), the Liquicap provides an ideal inventory management solution.

 

Advantages

No calibration required for liquids with conductivity above 100μS/cm; probe length factory preset to 0%/100%, fast and simple commissioning

Text display with menu-guided on-site setup (optional)

Various approvals and permits obtained for a wide range of applications

Compliant with IEC 61508, suitable for safety systems requiring SIL2

Wetted parts made of corrosion-resistant and FDA-approved materials

Dual overvoltage protection (gas discharge tube + protective diode) prevents tank discharge

Electronics provide built-in buildup compensation

 

Areas of application

The Liquicap FMI52 has a robust construction (self-sealing cone); the probe withstands pressures from vacuum to 100bar. Sealing and isolating materials used in the tank can withstand temperatures from -80 to +200°C. For liquids with conductivity above 100μS/cm, the measured value is independent of the DK (dielectric constant), so different liquids can be measured without recalibration.

Spare Parts & Accessories 41

41 spare parts · click to collapse
Order codeDescription
52005984plug connectorwith gasket for Aluminium and stainless steel housingDetails
52002698Aluminum coverO-ring EPDM for Aluminium housing F13, Ex dDetails
52006903Aluminum coverO-ring EPDM for Aluminium housing Liquiphant M/S, Liquicap M, Soliphant MDetails
52025605Transparent coverCover for display, polyester housing Gasket EPDM Liquicap T/Liquicap MDetails
52025606plastic coverGasket EPDM Polyester housingDetails
52027000Stainless Steel CoverGasket 67,5x2,9x1,5 VMQ/PTFE Stainless steel housing F15Details
52027708Stainless Steel CoverClaw for cover Gasket 67,5x2,9x1,5 VMQ/PTFE Stainless steel housing F15, approval 2,3,4,8,D,E Soliphant M approval C,D,E,F,H,J,L,M Liquicap M FMI51/FMI52Details
52028269cover with viewing windowSight glass: glass Gasket 67,5x2,9x1,5, VMQ/PTFE Stainless steel housing F15Details
52028270Aluminum coverSight glass: Glass O-ring 70,0x3,0 EPDM Aluminium housing F13/F17Details
52028271Aluminum coverSight glass: mineral glass individual tested, EEx d/XP O-ring EPDM, FDA 72,0x3,0 Aluminium housing T13Details
52007103Aluminum coverO-ring EPDM for terminal compartment Aluminium housing T13Details
52002699Aluminum coverO-ring EPDM for Aluminium housing F17Details
52004137O-ringCover seal set Polyester housing F16Details
52004277Seal kitconsists of: 10x O-ring 70,0x3,0 EPDMDetails
52008495Seal kitfor coverDetails
52028179gasketProfile gasket for cover Stainless steel housing F15Details
52028260electronic plug-in moduleContinuous 2-wire, 4-20mA Liquicap M FMI51/52Details
52028261electronic plug-in moduleContinuous 2-wire, PFM Liquicap M FMI51/52Details
52028266Digital display with mounting bracket4-line alphanumeric display Liquicap MDetails
942901-0001Rope shortening kit FMI52/FTI52PTFE version. Usage: FMI52, FTI52.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
All documents for this model
12 documents · click to expand
BA

操作手册 Liquicap M FMI51, FMI52 FEI57C PFM Chinese

Rev. 1417 48 pages
Preview
BA

Liquicap M FMI51, FMI52 FEI50H HART Chinese

HART Rev. 1417 100 pages
Preview
BA

Liquicap M FMI51, FMI52 FEI50H HART Chinese

HART Rev. 1310 108 pages
Preview
BA

BA Liquicap M FMI52 PFM Chinese

Rev. 0221 48 pages
Preview
BA

BA Liquicap M FMI52 HART Chinese

HART Rev. 0221 92 pages
Preview
BA

Liquicap M FMI51, FMI52 FEI57C PFM Operating Instructions English

Rev. 1417 48 pages
Preview
BA

Operating Instructions Liquicap M FMI51, FMI52 FEI50H HART English

HART Rev. 1417 104 pages
Preview
BA

Liquicap M FMI51, FMI52 Operating Instructions PFM English

Rev. 0707 58 pages
Preview
BA

Liquicap M FMI51, FMI52 Operating Instructions HART English

HART Rev. 0407 114 pages
Preview
BA

Liquicap M FMI52 PFM English

Rev. 0221 48 pages
Preview
BA

Liquicap M FMI52 HART English

HART Rev. 0221 96 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · capacitors — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is capacitors; the focus is capacitive sensing of level, interface or point limit.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing rod, cable or plate probes by dielectric constant and build-up tendency.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing rod, cable or plate probes by dielectric constant and build-up tendency, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means reliable detection despite build-up, with far fewer false alarms, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · capacitors — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on capacitors and the core task is capacitive sensing of level, interface or point limit.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So capacitors cannot be specified generically — it calls for choosing rod, cable or plate probes by dielectric constant and build-up tendency.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing rod, cable or plate probes by dielectric constant and build-up tendency, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is reliable detection despite build-up, with far fewer false alarms.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · capacitors — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted capacitors properly configured on the existing plant, with the aim of capacitive sensing of level, interface or point limit.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the capacitors configuration has to involve choosing rod, cable or plate probes by dielectric constant and build-up tendency.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing rod, cable or plate probes by dielectric constant and build-up tendency, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is reliable detection despite build-up, with far fewer false alarms, and the readings are now used for process tuning.

Power & Energy

Power & Energy · capacitors — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was capacitive sensing of level, interface or point limit.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing rod, cable or plate probes by dielectric constant and build-up tendency.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing rod, cable or plate probes by dielectric constant and build-up tendency, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — reliable detection despite build-up, with far fewer false alarms, with routine maintenance falling noticeably.