Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FTI52 Liquicap M

FTI52 Liquicap M
Liquicap M FTI52
Liquicap FTI52 is a rope probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids. Due to its active build-up compensation FTI52 offers maximum reliability and is suited for a wide range of applications thanks to international certificates. The parts in contact with the process are made of corrosion-resistant and FDA-listed materials - this guarantees a high safety standard.
Compare

Point Level / Liquids

Measuring Principle Capacitive Liquid
Characteristic / Application Capacitive Rope probe
Specialities Interface detection
Foam detection
Ambient temperature -50 °C ... +70 °C
(-58 °F ... +158 °F)
With separate housing:
-50 °C ... +120 °C
(-58°F ... +248 °F)
Process temperature -80 °C ... +200 °C
(-112 °F ... +392 °F)
Process pressure / max. overpressure limit Vacuum ... 100 bar
(Vacuum ... 1450 psi)
Main wetted parts Insulation material: FEP, PFA
316L
Process connection G 3/4 ... 1 1/2
NPT 3/4 ... 1 1/2
Flange from DN25.../ASME 1".../JIS 10K...
Process connection hygienic Tri-Clamp ISO2852 gap free plated
Dairy coupling
Flush mount
Sensor length Total length of probe: max 12m (39 ft)
Communication 2- wire 19-253 VAC
3-wire
PFM
Relay DPDT
DC-PNP
8/16 mA
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC
Safety approvals Overfill prevention WHG
SIL
Design approvals EN 10204-3.1
NACE MR0175
Marine approval GL/ ABS/ DNV
Options Inactive length
Active build-up compensation
Separate housing
Components Transmitter
PFM: FTC325, FTC625, FTC470Z, FTC471Z
3-wire:
FTC325
Application limits Notice the pressure and temperature derating.
Notice for non conductive medium the DK.

The Liquicap FTI52 uses a cable probe and can be used for limit detection of highly viscous liquids and liquids prone to buildup, as well as for interface and foam detection of conductive liquids. The FTI52 has buildup compensation for reliable measurement. The probe has obtained international approvals from various relevant industries and has a wide range of applications. Wetted parts use corrosion-resistant materials and FDA-approved materials to meet the highest safety standards.

 

Advantages

Fast and simple calibration and commissioning by key operation

Various approvals and permits for a wide range of applications

Wetted parts use corrosion-resistant materials and FDA-approved materials

Two-stage overvoltage protection prevents vessel discharge (gas discharge tube + protective diode)

Short response time of the measured value

No calibration required after electronics replacement

Automatic electronics monitoring

 

Areas of application

The Liquicap M FTI51 is preferably used in the following measurement applications:

 

Applications with high viscosity and buildup tendency

Interface detection between different liquids (e.g. oil/water interface)

Two-point control via one process connection (pump control), foam detection of conductive liquids

The probe has a robust, proven construction (self-sealing cone) and can be used in applications from vacuum to overpressure up to 100bar

Spare Parts & Accessories 42

42 spare parts · click to collapse
Order codeDescription
52002698Aluminum coverO-ring EPDM for Aluminium housing F13, Ex dDetails
52002699Aluminum coverO-ring EPDM for Aluminium housing F17Details
52006903Aluminum coverO-ring EPDM for Aluminium housing Liquiphant M/S, Liquicap M, Soliphant MDetails
52025606plastic coverGasket EPDM Polyester housingDetails
52027000Stainless Steel CoverGasket 67,5x2,9x1,5 VMQ/PTFE Stainless steel housing F15Details
52007103Aluminum coverO-ring EPDM for terminal compartment Aluminium housing T13Details
52004137O-ringCover seal set Polyester housing F16Details
52004277Seal kitconsists of: 10x O-ring 70,0x3,0 EPDMDetails
52008495Seal kitfor coverDetails
52028179gasketProfile gasket for cover Stainless steel housing F15Details
71084478Separate Type Cable F15/F16/F17, FTIxxConnection sensor > separate housing. Length: 6m. Housing adapter, cable gland. Usage: separate housing, FTI51/FTI52/ FTI55/FTI56, FTI77.Details
71025814electronic plug-in module19-253VAC, 19-55VDC Liquicap M FTI51/52Details
71025815electronic plug-in moduleLiquicap M FTI51/52Details
71025816electronic plug-in moduleLiquicap M FTI51/52Details
71025819electronic plug-in module3-wire PNP Liquicap M FTI51/52Details
71025820electronic plug-in module3-wire Liquicap M FTI51/52Details
71042887electronic plug-in module2-wire. Usage: FTI51/FTI52/FTI55/FTI56, FTI77.Details
71100895electronic plug-in module8/16mA, 11-36VDC. Usage: FTI51/FTI52/FTI55/FTI56, FTI77.Details
71020804Terminal moduleUsage: FMI51/FMI52, FTI51/FTI52/FTI55/FTI56, FTI77.Details
942901-0001Rope shortening kit FMI52/FTI52PTFE version. Usage: FMI52, FTI52.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play
All documents for this model
12 documents · click to expand
BA

Liquicap M FTI51, FTI52 Chinese

Rev. 1417 76 pages
Preview
BA

Liquicap M FTI51, FTI52 Chinese

Rev. 1310 84 pages
Preview
BA

BA Liquicap M FTI52 Chinese

Rev. 0224 84 pages
Preview
BA

Operating Instructions Liquicap M FTI51, FTI52 English

Rev. 1417 80 pages
Preview
BA

BA Liquicap M FTI52 English

Rev. 0224 88 pages
Preview
BA

Liquicap M FTI51, FTI52 Operating Instructions English

Rev. 0110 102 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

技术资料 Liquicap M FTI51, FTI52 Chinese

Rev. 1310 48 pages
Preview
TI

TI Liquicap M FTI52 Chinese

Rev. 0325 52 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

Technical Information Liquicap M FTI51, FTI52 English

Rev. 1417 48 pages
Preview
TI

TI Liquicap M FTI52 English

Rev. 0325 52 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · capacitors — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is capacitors; the focus is capacitive sensing of level, interface or point limit.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing rod, cable or plate probes by dielectric constant and build-up tendency.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing rod, cable or plate probes by dielectric constant and build-up tendency, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means reliable detection despite build-up, with far fewer false alarms, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · capacitors — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on capacitors and the core task is capacitive sensing of level, interface or point limit.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So capacitors cannot be specified generically — it calls for choosing rod, cable or plate probes by dielectric constant and build-up tendency.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing rod, cable or plate probes by dielectric constant and build-up tendency, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is reliable detection despite build-up, with far fewer false alarms.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · capacitors — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted capacitors properly configured on the existing plant, with the aim of capacitive sensing of level, interface or point limit.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the capacitors configuration has to involve choosing rod, cable or plate probes by dielectric constant and build-up tendency.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing rod, cable or plate probes by dielectric constant and build-up tendency, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is reliable detection despite build-up, with far fewer false alarms, and the readings are now used for process tuning.

Power & Energy

Power & Energy · capacitors — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was capacitive sensing of level, interface or point limit.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing rod, cable or plate probes by dielectric constant and build-up tendency.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing rod, cable or plate probes by dielectric constant and build-up tendency, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — reliable detection despite build-up, with far fewer false alarms, with routine maintenance falling noticeably.