Technical Data
ComparePoint Level / Solids
| Measuring Principle | Capacitive Solid |
| Characteristic / Application | Compact for all types of powdered solids / small-grain bulk solids |
| Specialities | Active build-up compensation |
| Supply / Communication | 12 V...30 VDC |
| Ambient temperature | -20°C...+60°C (-4°F...+140°F) |
| Process temperature | -20°C...+80°C (-4°F...+176°F) |
| Main wetted parts | PC, ECTFE "Protector" FDA listed material PBT-GF (according to 21 CFR 177.1660) |
| Process connection | G1 |
| Communication | 12 V...30 VDC IO-Link |
| Safety approvals | ATEX, CSA C/US, IEC Ex, EAC Ex |
| Design approvals | EN 10204-3.1 |
| Hygienic approvals | 3-A, EHEDG |
The Nivector FTI26 is an economical level switch for powder applications in the food industry and various industries. The capacitive device has optimal anti-adhesion performance and extremely high sensitivity. It has certificates compliant with the standards of various industries. In addition, the FTI26 features IO-Link communication, meeting the requirements of Industry 4.0.
Advantages
Compact design for simple installation, even in confined spaces or hard-to-access applications
Meets all relevant hygienic requirements (3A, EHEDG, FDA, EG1935/2004); washdown-capable (IP69)
IO-Link reduces operating costs and operational complexity; the instrument can be configured conveniently via design software
Highest level of anti-adhesion performance and extremely high sensitivity
No need for separate adjustment for each medium
On-site function check via LED display
Application areas
For low-limit or high-limit detection of powdery and fine-grained bulk solids, e.g. plastic granules, grain, sugar, spices, coffee powder, washing powder
Process connection: G1" thread, Tri-Clamp 2" clamp
Temperature: -20...+80°C (-4...+176°F)
Pressure: -1...+6bar (-14.5...+86psi)
International explosion protection approval (dust explosion protection) and hygienic approval
Spare Parts & Accessories 12
12 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71267011 | Test magnetUsage: FTL20/FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51H, FTW23, FTW33. | Details |
| 71280307 | Hirschmann connector M16Consists of: plug connector, screw, seal, valve plug ring, adapter ring. Usage: FTI26, FTL31/FTL33, FTW33, PMC11, PMC21, PMP11, PMP21/PMP23. | Details |
| 71280349 | Hirschmann connector NPTF1/2Consists of: plug connector, screw, seal, valve plug ring, adapter ring. Usage: FTI26, FTL31/FTL33, FTW33, PMC11, PMC21, PMP11, PMP21/PMP23. | Details |
| 71395785 | FTI26 probe protectorMounting adapter, thread G1-1/2. Material: PBT-GF, FDA listed. Temp.: -20...+80oC. Immersion: 63mm. :: Protection against abrasion. :: No solids flow at Nivector-exchange. Usage: FTI26. | Details |
| 71395862 | FTI26 probe protectorMounting adapter, thread R1-1/2. Material: PBT-GF, FDA listed. Temp.: -20...+80oC. Immersion: 63mm. ::Protection against abrasion. ::No solids flow at Nivector-exchange. Usage: FTI26. | Details |
| 71416936 | protectorMounting adapter, thread G1-1/2. Material: PBT-GF, FDA listed. Temp.: -20...+80oC, immersion: 63mm. :: Protection against abrasion. :: No solids flow at Nivector-exchange. Usage: FTI26. | Details |
| 71444431 | Sanitary adapter G1>Clamp-2, with threaded sleeve and sealing ringProcess adapter G1. Material: 316L. Profile seal: VQM60C3, transparent. FDA, EHEDG, 3-A conform. Usage: FTI26. | Details |
| 71444432 | Sanitary weld seat G1, FTI26Material: 316L. Profile seal: VQM60C3, transparent. FDA, EHEDG, 3-A conform. Usage: FTI26. | Details |
| 71395801 | FTI26 Lock NutMounting aid. Material: plastic PA. Wrench size: 41mm. Usage: FDU90/FDU91/FDU92, FMR10/FMR20, FTC968 AC, FTI26. | Details |
| 71395803 | FTI26 Explosion-Proof SheathMaterial: PC. Mandatory for Ex-version. W/o Ex-protection cover the following Ex-protection is not guaranteed: FTI26: Dust Ex-protection. PMC21, PMP21: Ex ec approval. | Details |
| 52018763 | Cable with connector | Cable 4x0.34, box M12, 316L, LED, 9适用于M12插头,集成LED指示 带5m电缆 PVC 材质 316L锁紧螺母 针对卫生型应用 | Details |
| 52006263 | Process connection | Socket for plug 4p-125V, 4A-M12M12 插头 自连接 M12转成格兰 | Details |
Configurator / Comparison
Accessories / Spare parts
Source:Endress+Hauserpublic information from the website
Measuring principle video
Click to playManuals & Documents 8
All documents for this model8 documents · click to expand
Nivector FTI26 操作手册 Chinese
Nivector FTI26 操作手册 Chinese
Nivector FTI26 Operating Instructions English
Nivector FTI26 Operating Instructions English
TI 焊接接头、过程转接头和法兰 Chinese
Nivector FTI26 技术资料 Chinese
TI Weld-in adapter, process adapter and flanges English
Nivector FTI26 Technical Information English
Case Studies
Municipal Wastewater Treatment · capacitors — Application Case
Customer Profile
The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is capacitors; the focus is capacitive sensing of level, interface or point limit.
Key Difficulties
Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing rod, cable or plate probes by dielectric constant and build-up tendency.
Implementation
The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing rod, cable or plate probes by dielectric constant and build-up tendency, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.
Customer Benefit
In practice this means reliable detection despite build-up, with far fewer false alarms, which cut the workload on the site maintenance team.
Food & Beverage · capacitors — Application Case
Project Background
The project covers dosing, pasteurising, filling and CIP stages. The work centres on capacitors and the core task is capacitive sensing of level, interface or point limit.
Operating Challenges
The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So capacitors cannot be specified generically — it calls for choosing rod, cable or plate probes by dielectric constant and build-up tendency.
Solution
The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing rod, cable or plate probes by dielectric constant and build-up tendency, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.
Results
Since start-up the system has run steadily; the practical result is reliable detection despite build-up, with far fewer false alarms.
Chemical & Pharmaceutical · capacitors — Application Case
Project Overview
The site is reactors, metering vessels and finished-product tanks. The customer wanted capacitors properly configured on the existing plant, with the aim of capacitive sensing of level, interface or point limit.
Technical Challenges
What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the capacitors configuration has to involve choosing rod, cable or plate probes by dielectric constant and build-up tendency.
Configuration
Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing rod, cable or plate probes by dielectric constant and build-up tendency, checked line by line against: Ex certification and GMP traceability of records.
Performance
After commissioning the outcome is reliable detection despite build-up, with far fewer false alarms, and the readings are now used for process tuning.
Power & Energy · capacitors — Application Case
Site Conditions
This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was capacitive sensing of level, interface or point limit.
The Problem
The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing rod, cable or plate probes by dielectric constant and build-up tendency.
What We Did
We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing rod, cable or plate probes by dielectric constant and build-up tendency, with point-by-point checks on: compliance with power-industry codes and unit availability targets.
Operating Outcome
In service the system performs as intended — reliable detection despite build-up, with far fewer false alarms, with routine maintenance falling noticeably.