Minicap FTC262 is a simple and cost-effective rope probe for point level detection in bulk solids, particularly suited to applications involving aggressive media and heavy build-up. It is designed for point level detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum.
Compare

Point Level / Solids

Measuring Principle Capacitive Solid
Characteristic / Application No calibration on start-up
Active build-up compensation
Mechanically robust
The rope probe can be shortened
(optimum matching to the measuring point)
Specialities Rope shortening parts to be supplied by the customer
Supply / Communication 10,8 ... 45V DC, DC-PNP 3-wire
20 ... 253V AC, or
20 ... 55V DC, Relay output
Ambient temperature -40°C...+70 °C(-40°F...+158°F)
Process temperature -40°C...+80°C
(-40°F ...+176 °F)
Process pressure / max. overpressure limit -1 ... 6 bar(-14.5 ... 90 psi)
Main wetted parts PPS = Polyphenylene sulphide
(glass fibre content approx. 40%)
Max. tensile strength 3000 N
Process connection R 1 1/2
NPT 1 1/2
Sensor length min. 500 mm (20"), max 6000 mm (236")
Communication PNP transistor output
Relay output (potential-free
change-over contact / SPDT)
Certificates / Approvals ATEX , IEC Ex, FM, CSA, NEPSI, UK Ex
Options Aluminium Housing
Application limits Solids, grain size max. 30 mm (1.2"),
DK min 1,5
Flexural strength 1400 N (at probe tip)

The Minicap FTC262 cable probe has a simple structure, is economical and practical, and is used for limit detection of bulk solids, especially for corrosive media or media with heavy buildup. The probe is specially designed for limit detection of light bulk solids. Typical applications: grain, flour, milk powder, animal feed, cement, talc or gypsum.

 

Advantages

The measuring system consists of the probe and electronics:

——easy installation

——no calibration at startup

Built-in buildup compensation:

——precise switching action is maintained even with heavy probe buildup

——high operational safety

Robust mechanical parts:

——no wearing parts

——long service life

——maintenance-free

The Minicap FTC262 cable probe can be shortened

-optimized length to match the measuring point in the silo

-reduced inventory

 

Areas of application

Minicap is specially designed for limit detection of light bulk solids with a maximum particle size of 30mm and a dielectric constant of εr ≥ 1.6. Typical applications: grain, flour, milk powder, animal feed, cement, talc or gypsum.

Model:

 

Minicap FTC262: with cable probe up to 6 meters long, for bulk solids measurement

Relay output with AC or DC power supply (spare auxiliary changeover power/SPDT)

PNP output with 3-wire DC power supply

Spare Parts & Accessories 9

9 spare parts · click to collapse
Order codeDescription
543223-0011Housing F14 PBT, Pg13, coverMaterial: Polyester. Usage: Minicap. -For E+H service only-Details
543201-0000Cover F14 PBT, gasketO-ring EPDM. Usage: housing Polyester.Details
943201-1001Cover F14 PE, transparent PASight glass: Polycarbonat PA.Details
71092705Aluminum coverMaterial: aluminium. O-ring: EPDM. Not for Ex d/XP. Usage: FMB50/FMB51/FMB52/FMB53, FTC260/FTC262, PMC51, PMD55, PMP51/PMP55.Details
71092707Aluminum coverMaterial: aluminium. Sight glass: mineral glass. O-ring: EPDM. Not for Ex d/XP. Usage: FMB50/FMB51/FMB52/FMB53, FTC260/FTC262, PMC51, PMD55, PMP51/PMP55.Details
52020429Seal ring assemblyconsists of: 5x O-ring 75,87x2.62, EPDM, PTFE, FDADetails
52005634electronic plug-in module20-253VAC/20-55VDCDetails
52005636electronic plug-in moduleElectronics FTC262 Ex 10,8-45VDC, PNPDetails
52005918cable shortening tool可用于:FTC262Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
14 models · click to collapse
All documents for this model
2 documents · click to expand
TI

技术资料 Minicap FTC260, FTC262 Chinese

Rev. 1616 16 pages
Preview
TI

Technical Information Minicap FTC260, FTC262 English

Rev. 1719 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · capacitors — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is capacitors; the focus is capacitive sensing of level, interface or point limit.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing rod, cable or plate probes by dielectric constant and build-up tendency.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing rod, cable or plate probes by dielectric constant and build-up tendency, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means reliable detection despite build-up, with far fewer false alarms, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · capacitors — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on capacitors and the core task is capacitive sensing of level, interface or point limit.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So capacitors cannot be specified generically — it calls for choosing rod, cable or plate probes by dielectric constant and build-up tendency.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing rod, cable or plate probes by dielectric constant and build-up tendency, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is reliable detection despite build-up, with far fewer false alarms.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · capacitors — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted capacitors properly configured on the existing plant, with the aim of capacitive sensing of level, interface or point limit.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the capacitors configuration has to involve choosing rod, cable or plate probes by dielectric constant and build-up tendency.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing rod, cable or plate probes by dielectric constant and build-up tendency, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is reliable detection despite build-up, with far fewer false alarms, and the readings are now used for process tuning.

Power & Energy

Power & Energy · capacitors — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was capacitive sensing of level, interface or point limit.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing rod, cable or plate probes by dielectric constant and build-up tendency.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing rod, cable or plate probes by dielectric constant and build-up tendency, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — reliable detection despite build-up, with far fewer false alarms, with routine maintenance falling noticeably.