Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FMU43 Prosonic MDiscontinued

FMU43 Prosonic M
Prosonic M FMU43Discontinued
Configurable Models 1 models
The Prosonic FMU43 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.
Compare

Continuous / Liquids

Measuring Principle
Characteristic / Application Compact ultrasonic transmitter
Supply / Communication 4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus
Accuracy +/- 4 mm or +/- 0.2 %of set measuring range
Ambient temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process pressure / max. overpressure limit 0.7 bar ... 2.5 bar abs
(10 psi ... 36 psi)
Main wetted parts Unsaturated Polyester, 316 Ti
Process connection DN 100, ASME 4"
Blocking distance 0.6 m (2 ft)
Communication 4 ... 20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, IEC, INMETRO, NEPSI

Continuous / Solids

Measuring Principle
Characteristic / Application Compact ultrasonic transmitter
Supply / Communication 4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus
Accuracy +/- 4 mm or +/- 0.2 %of set measuring range 1)
Ambient temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process pressure / max. overpressure limit 0.7 bar ... 2.5 bar abs
(10 psi ... 36 psi)
Main wetted parts unsaturated polyester, 316 Ti
Process connection DN 100, ASME 4"
Blocking distance 0.6 m (2 ft)
Max. measurement distance 7 m (23 ft)
Communication 4 ... 20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, IEC, INMETRO, NEPSI
Application limits Take notice of range diagram

Prosonic FMU43 is suitable for non-contact level measurement of liquids, pastes and bulk solids as well as flow measurement in open channels or measuring weirs. The two-wire or four-wire compact transmitter can be used for level measurement under demanding conditions in storage tanks, mixers, silos and on conveyor belts. The on-site envelope curve display enables simple device fault diagnostics. The linearization function (up to 32 points) converts the measured value into length, volume or flow in any unit.

Benefits

  • Four-line plain text display with menu-guided on-site operation for fast and simple device commissioning, available in 7 languages

  • On-site envelope curve display for simple device fault diagnostics

  • FieldCare operating software allows convenient remote operation, fault diagnostics and measuring point documentation

  • Suitable for hazardous areas (gas-Ex, dust-Ex)

  • Linearization function (up to 32 points) converts the measured value into length, volume or flow in any unit

  • Integrated temperature sensor automatically corrects the temperature-dependent speed of sound

  • Optional remote display and operation (max. installation distance from the transmitter up to 20 m (66 ft))

Application

Suitable for continuous non-contact level measurement of liquids, pastes, sludge and bulk solids; flow measurement in open channels and measuring weirs; system integration: HART (standard), 4…20 mA, PROFIBUS PA, FF Foundation Fieldbus; maximum measuring range: liquid: 5 m, solid: 2 m. Other measuring ranges: FMU41: liquid 8 m, solid 3.5 m; FMU42: liquid 10 m, solid 5 m; FMU43: liquid 15 m, solid 7 m; FMU44: liquid 20 m, solid 10 m

Common models: FMU43-APG2A2

 

Spare Parts & Accessories 37

37 spare parts · click to collapse
Order codeDescription
52020763plug connectorCerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
535720-9020Set of screws housing F12/T12/F23Consists of: 1x stop screw M5x10. 1x retaining screw M8x10. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.Details
52010526Seal kitconsists of: 1x O-ring 113.9x3.53 EPDM 1x O-ring 72.0x3.0 EPDM 1x O-ring 49.21x3.53 EPDM 1x flat gasket 47x58x2 EPDM 1x flat gasket 59x68x2.5 EPDM 2x O-ring 17,0x2,0 EPDMDetails
52005936Aluminum coverMaterial: Aluminium for operating + display module VU331 and housing F12/T12 Micropilot M/S, Prosonic M, Levelflex MDetails
517391-0011Cover F12/T12 Alu, coated, gasketMaterial: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.Details
52006026Terminal Chamber CoverHood for terminal compartment Micropilot M, Prosonic M, Levelflex MDetails
52019062Terminal Chamber CoverHood for terminal compartment for separate display Micropilot M, Prosonic M, Levelflex MDetails
71092209O-ringUsage: cover T12/F12/F23.Details
52012156Terminal modulePROFIBUS PA, FOUNDATION Fieldbus Micropilot II/M, Prosonic M, Levelflex MDetails
52013304Power Supplyfor electronics 4-wire Levelflex M, Prosonic MDetails
52013305Power Supplyfor electronics 4-wire Levelflex M, Prosonic MDetails
71396869Power supply module 90-250VAC (F12) v2, non-explosion-proofPower supply, HART, version 2. Only for "non ex area". Usage: FMU40/FMU41/FMU42/FMU43/FMU44.Details
52015585Power Supplyfor electronics 4-wire Levelflex M, Prosonic MDetails
52015586Power Supplyfor electronics 4-wire Levelflex M, Prosonic MDetails
FHX40-Remote display FHX40remote display + local operation Micropilot M, Prosonic M, Levelflex M, Gammapilot M in Aluminium field housing IP65 NEMA4X. 4-line LC-display. :: menu driven plain text operation :: Easy setup :: User language selectable :: envelope curve display on siteEnquire
71025602Circuit board4-20mA, version 4.0 Prosonic M FMU40/FMU41/FMU42Details
71344233Electronics FMU4x, Ex, PA, v4.0_2PROFIBUS PA, version 4.02. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.Details
71462298*** Module FMU4x, Ex, FF, v4.02.2FOUNDATION Fieldbus, version 4.02.2. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.Details
52026443Display unit VU3314-line alphanumeric display Micropilot M, Micropilot S, Prosonic M, Levelflex MDetails
71386715Display VU331, version 3Alphanumeric display, 4-line. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring Principle Video

Click to play

Source:Endress+Hauserwebsite public information

1 models · click to collapse
All documents for this model
12 documents · click to expand
BA

操作手册 Prosonic M FMU40/41/42/43/44 Chinese

Rev. 1312 76 pages
Preview
BA

Prosonic M FMU40/41/42/43/44 English

Rev. 1312 76 pages
Preview
BA

Prosonic M FMU40/41/42/43/44 English

Rev. 1312 84 pages
Preview
BA

Prosonic M FMU40/41/42/43/44 English

Rev. 1312 92 pages
Preview
BA

Prosonic M FMU40/41/42/43/44 English

Rev. 1312 100 pages
Preview
BA

Prosonic M FMU 40/41/42/43 4-20mA HART, PA, FF Description of Instrument Functions English

HART Rev. 0907 88 pages
Preview
BA

Prosonic M FMU 40/41/42/43 Foundation Fieldbus Operating Instructions English

FOUNDATION-Fieldbus Rev. 0109 112 pages
Preview
BA

Prosonic M FMU 40/41/42/43 4-20 mA HART Operating Instructions English

HART Rev. 0109 80 pages
Preview
BA

Prosonic M FMU 40/41/43 PROFIBUS-PA Operating Instructions English

PROFIBUS-PA Rev. 0109 92 pages
Preview
BA

Prosonic M FMU 40/41/42/43 Foundation Fieldbus Operating Instructions English

FOUNDATION-Fieldbus 84 pages
Preview
BA

Prosonic M FMU 40/41/42/43 4-20mA HART, PA, FF Description of Instrument Functions English

HART 80 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · ultrasound — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from ultrasound , focusing on ultrasonic liquid level measurement or interface detection.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The ultrasound specification must therefore cover sizing range against dead zone, mounting height and medium temperature.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on sizing range against dead zone, mounting height and medium temperature, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — retrofit without touching the tank, with short installation time, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · ultrasound — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is ultrasound ; the focus is ultrasonic liquid level measurement or interface detection.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with sizing range against dead zone, mounting height and medium temperature.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on sizing range against dead zone, mounting height and medium temperature, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means retrofit without touching the tank, with short installation time, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · ultrasound — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on ultrasound and the core task is ultrasonic liquid level measurement or interface detection.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So ultrasound cannot be specified generically — it calls for sizing range against dead zone, mounting height and medium temperature.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves sizing range against dead zone, mounting height and medium temperature, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is retrofit without touching the tank, with short installation time.

Power & Energy

Power & Energy · ultrasound — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted ultrasound properly configured on the existing plant, with the aim of ultrasonic liquid level measurement or interface detection.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the ultrasound configuration has to involve sizing range against dead zone, mounting height and medium temperature.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant sizing range against dead zone, mounting height and medium temperature, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is retrofit without touching the tank, with short installation time, and the readings are now used for process tuning.