Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FTI56 Solicap M

FTI56 Solicap M
Solicap M FTI56
Configurable Models 3 models
Solicap FTI56 is a fully/partly insulated and robust rope probe for point level detection of fine-grained to coarse-grained bulk solids. It offers maximum reliability and is suited for a wide range of applications thanks to numerous certificates and approvals. Due to its robust construction, it can also be used to provide accurate measurements in applications with very high tensile loads up to 60kN.
Compare

Point Level / Solids

Measuring Principle Capacitive Solid
Characteristic / Application Fully / partly isulated rope probe for small-grain / large-grain solids
Simple calibration
Suitable for abrasive media
Very robust probe
Specialities Inactive length
High tensile loading
Extremely robust probe
Supply / Communication 19 ... 253V AC
10 ... 55V DC-PNP
19...253V AC bzw 10...55V DC
8/16mA, 11 ... 36V DC
PFM
3-wire
Ambient temperature -50°C ... 70°C
(-58°F ... 158°F)
Process temperature -50°C ... 180°C
(-58°F ... 356°F)
Process pressure / max. overpressure limit Vacuum ... 25 bar
(Vacuum ... 362 psi)
Main wetted parts PTFE, PA, 316L, Steel
Max. tensile strength 60 kN
Process connection Thread R1 1/2, NPT1 1/2
Flanges from DN50.../ASME 2".../JIS...
Sensor length 0.5m ... 22m
(1.6ft ... 72ft)
Inactive length: 0.1m....1m
(3"...39")
Communication 2- wire 19-253 VAC
DC PNP
Relais DPDT
PFM
3-wire
8/16 mA
Certificates / Approvals ATEX, FM, CSA, IEC Ex, JPN Ex, NEPSI
Safety approvals SIL
Components PFM: FTC325, FTC625, FTC470Z, FTC471Z
3-wire: FTC325
Application limits DK min 2

The Solicap FTI56 fully or partially insulated cable probe has a robust construction and is used for limit detection of fine and coarse-grained solids. With its automatic buildup compensation, the probe provides the highest measurement reliability and has obtained various relevant approvals and permits for a wide range of applications. Thanks to its robust, wear-resistant construction, it also provides high-precision measurement in applications with tensile loads of up to 60kN.

 

Advantages

Ultra-robust probe specially designed for demanding process conditions

Significant cost savings thanks to fast and simple one-button calibration and commissioning

Various approvals and permits for a wide range of applications

Two-stage overvoltage protection against electrostatic discharge of the tank

Automatic buildup compensation for granular solids prone to caking

Permanent self-monitoring of the electronics increases safety

Rod sensors (partially insulated) and cable sensors (partially or fully insulated) can be shortened, reducing inventory costs

 

Areas of application

This compact transmitter is suitable for limit detection of fine and coarse-grained solids and can operate in minimum or maximum fail-safe mode. Thanks to its robust construction, it provides high-precision measurement even under extremely high tensile loads (maximum load of 60kN for cable sensors). It can be used together with Fieldgate (remote control of measured values via Internet technology) and is an ideal solution for raw material supply and logistics optimization (inventory control).

 

Process connections: flange or thread

Measuring range: 500~22,000mm (20~866")

Temperature: -50~+180°C (-58~+356°F)

Pressure: -1~+25bar (-14.5~+363psi)

International explosion protection approval, SIL approval

Spare Parts & Accessories 26

26 spare parts · click to collapse
Order codeDescription
52025606plastic coverGasket EPDM Polyester housingDetails
52002698Aluminum coverO-ring EPDM for Aluminium housing F13, Ex dDetails
52002699Aluminum coverO-ring EPDM for Aluminium housing F17Details
52027000Stainless Steel CoverGasket 67,5x2,9x1,5 VMQ/PTFE Stainless steel housing F15Details
52006903Aluminum coverO-ring EPDM for Aluminium housing Liquiphant M/S, Liquicap M, Soliphant MDetails
52007103Aluminum coverO-ring EPDM for terminal compartment Aluminium housing T13Details
52004137O-ringCover seal set Polyester housing F16Details
52004277Seal kitconsists of: 10x O-ring 70,0x3,0 EPDMDetails
52028179gasketProfile gasket for cover Stainless steel housing F15Details
52008495Seal kitfor coverDetails
71084478Separate Type Cable F15/F16/F17, FTIxxConnection sensor > separate housing. Length: 6m. Housing adapter, cable gland. Usage: separate housing, FTI51/FTI52/ FTI55/FTI56, FTI77.Details
71114540counterweightMaterial: 316L. Grub screw M8x12. Usage: FTI56, FTI77, rope 6mm 316L.Details
71114541counterweightMaterial: 316L. Grub screw M10x16. Usage: FTI56, FTI77, rope 12mm 316L.Details
71114539counterweightMaterial: steel galvanized. Grub screw M8x12. Usage: FTI77, rope 6mm steel, FTI56, rope 8mm steel, PA isolation.Details
71114537counterweightMaterial: cast iron. Grub screw M10x16. Usage: FTI56, rope 14mm steel, PA insulated.Details
71042887electronic plug-in module2-wire. Usage: FTI51/FTI52/FTI55/FTI56, FTI77.Details
71025819electronic plug-in module3-wire PNP Liquicap M FTI51/52Details
71025820electronic plug-in module3-wire Liquicap M FTI51/52Details
71025814electronic plug-in module19-253VAC, 19-55VDC Liquicap M FTI51/52Details
71025815electronic plug-in moduleLiquicap M FTI51/52Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
3 models · click to collapse
All documents for this model
11 documents · click to expand
BA

BA Solicap M FTI56 Chinese

Rev. 0224 88 pages
Preview
BA

Solicap M FTI55, FTI56 Chinese

Rev. 0110 96 pages
Preview
BA

Solicap M FTI55, FTI56 Operating Manual English

Rev. 1315 92 pages
Preview
BA

BA Solicap M FTI56 English

Rev. 0224 88 pages
Preview
BA

Solicap M FTI55, FTI56 Operating Manual English

Rev. 0110 96 pages
Preview
TI

Solicap M FTI55, FTI56 Chinese

Rev. 1315 44 pages
Preview
TI

TI Solicap M FTI56 Chinese

Rev. 0325 44 pages
Preview
TI

Solicap M FTI55, FTI56 Chinese

Rev. 0110 48 pages
Preview
TI

Solicap M FTI55, FTI56 Technical Information English

Rev. 1315 48 pages
Preview
TI

TI Solicap M FTI56 English

Rev. 0325 44 pages
Preview
TI

Solicap M FTI55, FTI56 Technical Information English

Rev. 0110 52 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · capacitors — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is capacitors; the focus is capacitive sensing of level, interface or point limit.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing rod, cable or plate probes by dielectric constant and build-up tendency.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing rod, cable or plate probes by dielectric constant and build-up tendency, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means reliable detection despite build-up, with far fewer false alarms, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · capacitors — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on capacitors and the core task is capacitive sensing of level, interface or point limit.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So capacitors cannot be specified generically — it calls for choosing rod, cable or plate probes by dielectric constant and build-up tendency.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing rod, cable or plate probes by dielectric constant and build-up tendency, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is reliable detection despite build-up, with far fewer false alarms.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · capacitors — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted capacitors properly configured on the existing plant, with the aim of capacitive sensing of level, interface or point limit.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the capacitors configuration has to involve choosing rod, cable or plate probes by dielectric constant and build-up tendency.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing rod, cable or plate probes by dielectric constant and build-up tendency, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is reliable detection despite build-up, with far fewer false alarms, and the readings are now used for process tuning.

Power & Energy

Power & Energy · capacitors — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was capacitive sensing of level, interface or point limit.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing rod, cable or plate probes by dielectric constant and build-up tendency.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing rod, cable or plate probes by dielectric constant and build-up tendency, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — reliable detection despite build-up, with far fewer false alarms, with routine maintenance falling noticeably.