Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

IFL200 Ultrasonic flowmeter

IFL200 Ultrasonic flowmeter
Ultrasonic flowmeter
FLOWSIC200 The tunnel flow measurement instrument is capable of long-term operation

FLOWSIC200 tunnel flow measuring instrument for long-term operation

Advantages

  • Highly representative measurement over the entire tunnel width

  • More reliable than selective measuring methods

  • Accurately measures very low flow velocities

  • Maintenance interval of up to 5 years

  • Reliable operation and low maintenance costs result in very low operating costs

  • High availability of the measuring instrument and its measuring data

Field of application

The FLOWSIC200 accurately measures the flow velocity and direction in tunnels or exhaust ducts without contact. The ultrasonic measuring method provides the average flow velocity over the entire tunnel width. When measuring climate-related and traffic-related air flows, the instrument enables effective and economical control of tunnel ventilation.
Even in the event of a tunnel fire, the flow velocity and direction can be measured reliably, accurately and representatively over the entire tunnel width. Only in this way can smoke propagation be determined and the necessary information for ideal ventilation control be obtained.

  • Measurement in road and rail tunnels

  • For controlling tunnel ventilation

  • Detecting smoke propagation


Overview:

  • Very large measuring distances

  • Non-contact measurement

  • Components made of titanium, stainless steel or die-cast alloy are extremely robust

  • Suitable for particularly corrosive tunnel environments

  • Detects the flow direction

  • No mechanical moving parts

Spare Parts & Accessories 23

23 spare parts · click to collapse
Order codeDescription
2034661Digital output module for S800, 4-channel connection, 48V AC/DC 0.5AAssemblies Description: “digital output” I/O module, 4 channels, as normally open, 48 V AC/DC, 0.5 A Type: Spare part Suitable for: SMOTEC450, VICOTEC450, GM32, VICOTEC320Details
2048076TRANSDUCER D60F18TI- 200 HSensors Description: Transducer installation for FLSE200-H Type: Sensors Suitable for: FLOWSIC200Details
2048079E-UNIT FL200 HPrinted-circuit board assemblies Description: Electronic unit R 200-H 1 W electronic unit for housing for S/R unit FLSE200-M Type: Printed-circuit board assemblies Suitable for: FLOWSIC200Details
2048080E-UNIT FL200 MPrinted-circuit board assemblies Description: Electronic unit R 200-M 1 W electronic unit for housing for S/R unit FLSE200-M Type: Printed-circuit board assemblies Suitable for: FLOWSIC200Details
2048085Door MCU-NWSD/N2SD with DisplayHousing parts Description: Housing door, including display and seal, for MCU-NWOD and MCU-N2OD Type: Spare part Suitable for: DUSTHUNTER T200, DUSTHUNTER T100, DUSTHUNTER T50, DUSTHUNTER SB100, DUSTHUNTER SB50, DUSTHUNTER SP100, DUSTHUNTER C200, DUSTHUNTER SF100, SMOTEC450, VICOTEC450Details
2055183Tube with Transducer + Cable SPSensors Description: Tube with transducer for FLSE200 M Type: Sensors Suitable for: FLOWSIC200Details
2140156PLUG, 7P CONFIG L=250 SPMale Connector for electronic unit, 7 pins, Cable length 250mmDetails
2034659Digital Output Module, 2-channelAssemblies Description: “digital output” I/O module, 2 channels, as changeover contact, 48 V AC/DC, 5 A or 30 V AC/DC, 2 A Type: Spare part Suitable for: SMOTEC450, VICOTEC450, MCS100FT, MCS300PDetails
2050590Power supply module, cold-device mount, testedVoltage supplies Description: Power supply unit, 88 V AC ... 264 V AC / 24 V DC, 3.2 A, 75 W, with plug connection and module carrier Note: Warning: Only for 19” version control unit! Type: Spare part Suitable for: SMOTEC450, VICOTEC450Details
2050591POWER SUPPLY MODULE, CLAMP-MOUNTED, TESTEDVoltage supplies Description: Power supply unit, 88 V AC ... 264 V AC / 24 V DC, 3.2 A, 75 W, with terminal connection and module carrier Note: Warning: Only for 19” version control unit! Type: Spare part Suitable for: SMOTEC450, VICOTEC450Details
2052234PCBA-PROCESSOR 19Z MCU TESTEDPrinted-circuit board assemblies Description: “Processor” printed-circuit board assembly, for 19” type control unit Type: Spare part Suitable for: SMOTEC450, VICOTEC450, DUSTHUNTER SB30Details
2065868Front Panel Module MCU 19" Instrument SpareHousing parts Description: Front cover with LC display for MCU/MCUP 19 inch version Type: Spare part Suitable for: FLOWSIC100, FLOWSIC100 Flare, FLOWSIC200Details
2032243DUCT PROBE PH-S D60SS0750 K170Housing parts Description: Duct probe PH-S D60SS0750 K170 NL 750, stainless steel, for S/R unit PHD-S/PH-S, without transducer Type: Housing parts Suitable for: FLOWSIC100Details
2032246Duct Probe PH-S D60SS0550 K170Housing parts Description: Duct probe PH-S D60SS550 K170 NL 550, stainless steel, for S/R unit PHD-S/PH-S, without transducer Type: Housing parts Suitable for: FLOWSIC100Details
2047154MOUNTING KIT K178Mounting Description: Mounting kit K178 for FLOWSIC100 H, PR, H-AC Type: Spare part Suitable for: FLOWSIC100Details
2047155MOUNTING KIT K121Mounting Description: Mounting kit K121 for FLOWSIC100 M, S, M-AC Type: Spare part Suitable for: FLOWSIC100Details
2062078PCBA-E/A-PROC FRAM + RS485 SERVICE TEST.Printed-circuit board assemblies Description: Processor board, with FRAM, including RS485 service interface Type: Spare part Suitable for: FLOWSIC100 FlareDetails
2062084Power Supply Unit CORTEM HOU GEPRVoltage supplies Description: Power supply unit MCUP ATEX zone 1 Cortem housing for MCUP ATEX zone 1 Cortem housing Type: Spare part Suitable for: FLOWSIC100 FlareDetails
2062105Sealing set for retraction mechanism ExS HT SPSeals Description: Sealing set for EX-S exchange mechanism, high temperature area internal and external seals for exchange nozzles, including installation material, high temperature –70... +280 °C Type: Spare part Suitable for: FLOWSIC100 FlareDetails
2065857Housing Kit Spare Parts AL M20Assemblies Description: Accessory set for electronics housing Ex-d Al metric incl. cover for Ex-d housing, cover lock, screws, spring rings, O-ring, earth connection, metric protective caps Type: Spare part Suitable for: FLOWSIC100 FlareDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

 

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Ultrasonic flowmeter — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Ultrasonic flowmeter properly configured on the existing plant, with the aim of transit-time ultrasonic measurement of liquid or gas flow.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Ultrasonic flowmeter configuration has to involve checking straight runs, pipe internal condition and entrained gas.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant checking straight runs, pipe internal condition and entrained gas, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clamp-on versions avoid pipe work, minimising shutdown in revamps, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Ultrasonic flowmeter — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was transit-time ultrasonic measurement of liquid or gas flow.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking straight runs, pipe internal condition and entrained gas.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around checking straight runs, pipe internal condition and entrained gas, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clamp-on versions avoid pipe work, minimising shutdown in revamps, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Ultrasonic flowmeter — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Ultrasonic flowmeter, focusing on transit-time ultrasonic measurement of liquid or gas flow.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Ultrasonic flowmeter specification must therefore cover checking straight runs, pipe internal condition and entrained gas.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on checking straight runs, pipe internal condition and entrained gas, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clamp-on versions avoid pipe work, minimising shutdown in revamps, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Ultrasonic flowmeter — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Ultrasonic flowmeter; the focus is transit-time ultrasonic measurement of liquid or gas flow.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking straight runs, pipe internal condition and entrained gas.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on checking straight runs, pipe internal condition and entrained gas, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit