IFL500 Ultrasonic flowmeter

IFL500 Ultrasonic flowmeter
Ultrasonic flowmeter
FLOWSIC500 ultrasonic flowmeter, custody transfer measurement in natural gas distribution

FLOWSIC500 ultrasonic flowmeter, custody transfer measurement in natural gas distribution

Advantages

  • Highest measurement certainty and safety for continuous gas supply

  • Lower installation costs thanks to integrated flow conversion

  • Simple installation, compatible with conventional technology (turbine and rotary
    displacement meters)

  • Lowest operating costs thanks to virtually maintenance-free operation

  • Simplified recalibration thanks to easy cartridge replacement

  • Reliable under dynamic load changes

  • Self-sufficient operation

Field of application

The FLOWSIC500 ultrasonic flowmeter enables extremely precise natural gas distribution measurement. It is overload-proof, accurate and monitored by an intelligent diagnostic system. It can be easily integrated into existing measuring stations. It can be operated either in a self-sufficient energy configuration or in fail-safe network operation with a backup battery. It complies with all relevant standards and directives and provides the safety of a continuous, non-blocking gas supply.

  • Distribution of natural gas for municipal and regional gas suppliers at transfer and measuring stations

  • Measuring stations in industrial and commercial applications


Device properties:

  • Diagnostics and permanent self-checking

  • Robust and reliable thanks to the absence of moving parts

  • Replaceable cartridge

  • No straight inlet/outlet sections required

  • Overload-proof

  • Optional integrated flow conversion/date registration

  • Battery or intrinsically safe power supply

Spare Parts & Accessories 30

30 spare parts · click to collapse
Order codeDescription
2064018Battery pack 2R20BATTERY UNIT 2R20 FLOWSIC500 battery pack (7.2V; 19Ah)" for autarkic meter operationDetails
2065928Battery Unit 2R6Backup battery (7,2 V; 2,7 Ah) for IS external power supplyDetails
2066077Display Mount, Tested, Spare PartDISPLAY MOUNT. TESTED SP Display module for FLOWSIC500 for output configuration A-E (type code)Details
2067398Closure Set NPT1/4 1.4571Plug for pressure connection NPT 1/4"Details
2067400CLOSURE SET G1/4 1.4571Plug for pressure connection G1/4"Details
2067401Closure set G1/2 1.4571Plug for temperature connection G1/2"Details
2069071Tube Fitting Set for Pipe D06 ST-VZFitting for pipe diameter 6mmDetails
2071174SP-EDT23-1000-0000RGX.E.I3 MOUNTEDT23 - digital pressure transmitter; gauge pressure 0 to 10 bar | 0 to 145 psi; G1/4'' external thread / Replaced by spare part PN 2117988Details
2071175SP-EDT23-0400-0000RGX.E.I3 MountEDT23 - digital pressure transmitter; gauge pressure 0 to 4 bar | 0 to 58 psi; G1/4" external thread / Replaced by PN 2117987Details
2071176ET-EDT23-2500-0000RGX.E.I3 MOUNTEDT23 - digital pressure transmitter; gauge pressure 0 to 25 bar | 0 to 362 psi; G1/4" external thread / Replaced by spare part PN 2117986Details
2071178FLOWSIC500 pressure sensor 0,8-5,2 BAR 12-75 PSIEDT23 - digital pressure transmitter; absolute pressure 0,8 to 5,2 bar | 12 to 75 psi; G1/4'' external threadDetails
2071179FLOWSIC500 pressure transmitter EDT23 absolute pressure 2-10 BAR 29-145 PSIEDT23 - digital pressure transmitter; absolute pressure 2 to 10 bar | 29 to 145 psi; G1/4'' external thread / Replaced by PN 2117983Details
2071180ET-EDT23-2000-0400AGX.E.I3 Absolute Pressure TransmitterEDT23 - digital pressure transmitter; absolute pressure 4 to 20 bar | 58 to 290 psi; G1/4" external thread / Replaced by PN 2117982Details
2071181ET-EDT34-60-25.E.I3 MountEDT34 - digital temperature transmitter, -25°C to +60°C | -13°F to 140°F / Replaced by PN 2147941Details
2071771SET TUBE FITTING PIPE 1/4" ST-VZFitting for pipe diameter 1/4"Details
2071777FLOWSIC500 Temperature TransmitterEDT34 - digital temperature transmitter, -40°C to +70°C | -40°F to 158°F / Replaced by PN 2147942Details
2075562Adapter NPT1/4 A - G 1/4 I SSAdapter NPT 1/4" external thread to G1/4" internal threadDetails
2087270Cleaning toolAuxiliary tool: assembly levers (2 pieces)Details
2087945RS485 module, input voltage 2.7...5 V, type I output configurationRS485 Module for FLOWSIC500 Rated input voltage 2,7 - 5VDetails
2087946RS485 module, input voltage 4...16 V, J-type output configurationRS485 Module for FLOWSIC500 Rated input voltage 4 - 16VDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

 

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Ultrasonic flowmeter — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Ultrasonic flowmeter properly configured on the existing plant, with the aim of transit-time ultrasonic measurement of liquid or gas flow.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Ultrasonic flowmeter configuration has to involve checking straight runs, pipe internal condition and entrained gas.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant checking straight runs, pipe internal condition and entrained gas, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clamp-on versions avoid pipe work, minimising shutdown in revamps, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Ultrasonic flowmeter — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was transit-time ultrasonic measurement of liquid or gas flow.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking straight runs, pipe internal condition and entrained gas.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around checking straight runs, pipe internal condition and entrained gas, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clamp-on versions avoid pipe work, minimising shutdown in revamps, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Ultrasonic flowmeter — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Ultrasonic flowmeter, focusing on transit-time ultrasonic measurement of liquid or gas flow.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Ultrasonic flowmeter specification must therefore cover checking straight runs, pipe internal condition and entrained gas.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on checking straight runs, pipe internal condition and entrained gas, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clamp-on versions avoid pipe work, minimising shutdown in revamps, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Ultrasonic flowmeter — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Ultrasonic flowmeter; the focus is transit-time ultrasonic measurement of liquid or gas flow.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking straight runs, pipe internal condition and entrained gas.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on checking straight runs, pipe internal condition and entrained gas, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clamp-on versions avoid pipe work, minimising shutdown in revamps, which cut the workload on the site maintenance team.