FLOWSIC550 high-pressure gas flowmeter for natural gas distribution
Advantages
-
High measurement reliability and continuous supply safety
-
Easy to install, compatible with turbine gas flowmeters
-
Integrated flow computer reduces installation costs
-
Simple commissioning and data readout via FLOWgateTM(PC and App)
-
Virtually maintenance-free, therefore significantly lower operating costs
-
Reliable under dynamic load changes
-
Can operate autonomously
Field of application
Advanced technology with higher measurement reliability: the new compact ultrasonic gas flowmeter FLOWSIC550 ensures highly precise metering of small volume flows in high-pressure networks —— an ideal complement to the FLOWSIC500. The FLOWSIC550 eliminates mechanical moving parts, operates reliably, guarantees fail-safe operation and low maintenance costs, thus significantly reducing operating costs. It features overload protection, enables reliable measurement and can be monitored via intelligent diagnostics. The FLOWSIC550 can be easily integrated into existing measuring stations. It can operate either self-powered or powered by the power grid. In transfer and measuring stations, the FLOWSIC550 ensures a continuous, non-blocking gas supply.
Spare Parts & Accessories 30
30 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 2133356 | SP-EDT96-7000-0000RGX.E.I2 MOUNTPressure sensor external EDT96-7000 gauge pressure 0…70 bar(g) Sensor incl. screw connection connection cable, sealing ring / | Details |
| 2133357 | SP-EDT96-0103-0000RGX.E.I2 MOUNTPressure sensor external EDT96-0103 gauge pressure 0…103 bar(g) Sensor incl. screw connection connection cable, sealing ring / | Details |
| 2133363 | High-temperature extension L380 WW SPTransducer cables FLOWSIC550 2"-4"/DN50-DN100 1 pair of transducer cables, MCX connectors / | Details |
| 2133365 | FC FIX SPFlow conditioner fixation screws FLOWSIC550 1 pair of fixation screws for flow conditioner assembly, incl. O-rings | Details |
| 2133366 | Seal Set FC FIX SPSealing set fixation screws FLOWSIC550 2 O-ring sealings | Details |
| 2133367 | SEAL SET ADAPTER SPU SPSealing set neck adapter FLOWSIC550 3 O-ring sealings | Details |
| 2133385 | COVER TRANSDUCER 2Z SPTransducer cover FLOWSIC550 2"/DN50 1 transducer cover, material: aluminum 1x transducer cover sealing 4x mounting screws incl. sealings | Details |
| 2133386 | COVER TRANSDUCER 3Z SPTransducer cover FLOWSIC550 3"/DN80 1 transducer cover, material: aluminum 1x transducer cover sealing 4x mounting screws incl. sealings | Details |
| 2133390 | O-ring set, transducer cover, 2Z SPTransducer cover sealing set FLOWSIC550 2"/DN50 1x transducer cover sealing 4x mounting screws incl. sealings | Details |
| 2133391 | O-ring set for transducer cover 3Z SPTransducer cover sealing set FLOWSIC550 3"/DN80 1x transducer cover sealing 4x mounting screws incl. sealings | Details |
| 2133394 | SET O-RINGS FC 2Z SPO-Ring set flow conditioner FLOWSIC550 2"/DN50 2x O-Ring | Details |
| 2133395 | SET O-RINGS FC 3Z SPO-Ring set flow conditioner FLOWSIC550 3"/DN80 2x O-Ring | Details |
| 2133398 | Locking screw M16*1,5 SPSet transducer lock screws FLOWSIC550 2 x lock screws, type M16*1,5 | Details |
| 2134829 | M8 SOCKETS SET SPM8 connection set FLOWSIC550 2x M8 connectors 2x connection cable to SPU board 2x connector cover | Details |
| 2134842 | Earthing Connection Set SPEarthing connection set FLOWSIC550 including cable, lock washers, fixing screws | Details |
| 2134847 | SMALL MATERIAL INTERNAL/EXTERNAL SPSmall materials set FLOWSIC550 earthing connector lock washers stand bolts thread lables, earthing label | Details |
| 2136052 | O-RING SET FOR CLEANING 2Z SPCleaning set FLOWSIC550 2"/DN50 O-Rings transducers O-Rings reflectors O-Rings flow conditioner O-Rings flow conditioner fixing screws Mounting grease | Details |
| 2136054 | SET O-RINGS CLEANING 3Z SPCleaning set FLOWSIC550 3"/DN80 O-Rings transducers O-Rings reflectors O-Rings flow conditioner O-Rings flow conditioner fixing screws Mounting grease | Details |
| 2138088 | EK-HA IIB 200 2P SPFLOWSIC550 SPU board, 200 kHz, IIB, 2 path configuration | Details |
| 2138707 | PROBE H210 TI200MB100P10 SPUltrasonic transducer pair H210 for FLOWSIC550 - material: titanium - design: 200 kHz, P10 - operating conditions: max. 105 bar(g), -46°C…+120°C | Details |
Configurator / Comparison
Source:Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment · Ultrasonic flowmeter — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Ultrasonic flowmeter properly configured on the existing plant, with the aim of transit-time ultrasonic measurement of liquid or gas flow.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Ultrasonic flowmeter configuration has to involve checking straight runs, pipe internal condition and entrained gas.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant checking straight runs, pipe internal condition and entrained gas, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is clamp-on versions avoid pipe work, minimising shutdown in revamps, and the readings are now used for process tuning.
Food & Beverage · Ultrasonic flowmeter — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was transit-time ultrasonic measurement of liquid or gas flow.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking straight runs, pipe internal condition and entrained gas.
What We Did
We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around checking straight runs, pipe internal condition and entrained gas, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — clamp-on versions avoid pipe work, minimising shutdown in revamps, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Ultrasonic flowmeter — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Ultrasonic flowmeter, focusing on transit-time ultrasonic measurement of liquid or gas flow.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Ultrasonic flowmeter specification must therefore cover checking straight runs, pipe internal condition and entrained gas.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on checking straight runs, pipe internal condition and entrained gas, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — clamp-on versions avoid pipe work, minimising shutdown in revamps, with confidence in this measuring point improving markedly.
Power & Energy · Ultrasonic flowmeter — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Ultrasonic flowmeter; the focus is transit-time ultrasonic measurement of liquid or gas flow.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking straight runs, pipe internal condition and entrained gas.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on checking straight runs, pipe internal condition and entrained gas, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means clamp-on versions avoid pipe work, minimising shutdown in revamps, which cut the workload on the site maintenance team.
Related Products
Endress+HauserProsonic Flow 93T portable
Endress+HauserProsonic Flow 91WA1 Clamp On 1Ch/1Set
Endress+HauserUltrasonic concentration meter D9FB
Endress+HauserUltrasonic flowmeter 93W
Endress+HauserUltrasonic flowmeter 9B2B
Endress+HauserUltrasonic concentration meter D9IB
Endress+HauserUltrasonic flowmeter
Endress+Hauser