FLOWSIC600 accurate and reliable ultrasonic flowmeter for process applications
Advantages
-
Long-term stable and reliable measurement
-
Intelligent self-checking function reduces maintenance costs
-
Virtually insensitive to pressure regulator noise
-
Ultrasonic sensors can be replaced under operating pressure
-
Wide range of applications
Field of application
The FLOWSIC600 ultrasonic flowmeter sets new market standards. It is specially designed for the demanding environmental conditions of certain industries. The compact design with integrated cable routing makes the measuring system durable, safe, reliable, low-maintenance and long-term stable. The FLOWSIC600 offers a wide variety of diagnostic options that enable early fault detection, prevent the measurement from being affected, and enable process monitoring via the speed of sound.
Spare Parts & Accessories 173
173 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 2031000 | SPU end cover seal lockHousing parts Description: MU clamp set (sealable) Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2031300 | Ex ATEX M20 FB RAL7012-AL Mounting HousingHousing parts Description: Electronics housing EEx M20 - with fuse board - material: aluminum Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2031302 | FLOWSIC 600 signal processing unit housing rear coverHousing parts Description: Electronics housing rear cover - material: aluminum - paint: RAL9002 Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2031304 | FLOWSIC 600 signal processing electrical enclosure EEx NPT 1/2Housing parts Description: Electronics housing EEx 1/2” NPT - with fuse board - material: aluminum Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2031456 | Analog Block 4-Path IIA/D 2L7 SPPrinted-circuit board assemblies Description: Analog block IIA/D 2L7 135 kHz - for devices with ATEX II 1/2 G EEx de ib [ia] IIA T4 - for devices with CSA Class 1 Division 1 Group D T4 Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2031485 | ANALOG BLOCK 4-PATH IIC/BCD 2L7 SPPrinted-circuit board assemblies Description: Analog block IIC/BCD 2L7 135 kHz - for devices with ATEX II 1/2 G EEx de ib [ia] IIC T4 - for devices with CSA Class 1 Division 1 Group D T4 Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2031633 | Probe extension cableCables Description: Sensor cable extension 650 mm (-55 .. 250 °C, type RG187) Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2031634 | Probe extension cable L850Cables Description: Sensor cable extension 850 mm (-55 .. 250 °C, type RG187) Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2032538 | PROBE D12F135MB250P18M27-W-X-T-V-X-X-28PSensors Description: Probe pair type 28 (135 kHz, 250 bar, 180 °C, titanium, P18) Type: Sensors Suitable for: FLOWSIC600 | Details |
| 2032578 | FLOWSIC600 probe extension cable L450Cables Description: Sensor cable extension 450 mm (-55 .. 250 °C, type RG187) Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2032579 | Extension 2XMU 4Z OFFS SS RAL9002Housing parts Description: Collar extension for high and low temperature applications, 200 mm length, for FLOWSIC600 4”, in stainless steel, painted RAL9002 Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2032600 | Extension HT L550 GGCables Description: Sensor cable extension 550 mm (-55 .. 250 °C, type RG187) Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2032601 | Connection extension cable L350Cables Description: Sensor cable extension 350 mm (-55 .. 250 °C, type RG187) Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2032787 | Operating Set LCD电气参数 描述: 带 LCD 设备的操作套件 类型: 备件 适用于: FLOWSIC600 | Details |
| 2033309 | HOUSING MOUNT EX ATEX M20 FB RAL7012-SSHousing parts Description: Electronics housing EEx M20 - with fuse board - material: stainless steel Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2033410 | MEPA INTERFACE-SET INTRINSIC SAFE EX辅助工具 描述: 本安型 MEPA 接口套件 (RS 485 / RS 232),带用于 RS 232 ATEX II (2) GD [EEx ib] IIC/IIB 和 II 3 G EEx nA II T4 的电缆 类型: 备件 适用于: FLOWSIC600 | Details |
| 2033761 | PRODUCT-CD FLOWSIC600Assemblies Description: FLOWSIC600 product CD (MEPAFLOW600, operating instructions, driver software) Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2034125 | FLOWSIC600 sensor S8 135 kHz, 100 bar, 180°, titanium, P18Sensors Description: Probe pair type S8 (135 kHz, 100 bar, 180 °C, titanium, P18) Type: Sensors Suitable for: FLOWSIC600 | Details |
| 2034376 | HT CRANK DI40 SSHousing parts Description: Collar extension for high and low temperature applications, 200 mm length, for FLOWSIC600 2”/3”/≥ 6”, in stainless steel, not painted Type: Spare part Suitable for: FLOWSIC600 | Details |
| 2034378 | Probe extension cable L1150Cables Description: Sensor cable extension 1 ,150 mm (-55 .. 250 °C, type RG187) Type: Spare part Suitable for: FLOWSIC600 | Details |
Configurator / Comparison
Source:Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment · Ultrasonic flowmeter — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Ultrasonic flowmeter properly configured on the existing plant, with the aim of transit-time ultrasonic measurement of liquid or gas flow.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Ultrasonic flowmeter configuration has to involve checking straight runs, pipe internal condition and entrained gas.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant checking straight runs, pipe internal condition and entrained gas, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is clamp-on versions avoid pipe work, minimising shutdown in revamps, and the readings are now used for process tuning.
Food & Beverage · Ultrasonic flowmeter — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was transit-time ultrasonic measurement of liquid or gas flow.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking straight runs, pipe internal condition and entrained gas.
What We Did
We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around checking straight runs, pipe internal condition and entrained gas, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — clamp-on versions avoid pipe work, minimising shutdown in revamps, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Ultrasonic flowmeter — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Ultrasonic flowmeter, focusing on transit-time ultrasonic measurement of liquid or gas flow.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Ultrasonic flowmeter specification must therefore cover checking straight runs, pipe internal condition and entrained gas.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on checking straight runs, pipe internal condition and entrained gas, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — clamp-on versions avoid pipe work, minimising shutdown in revamps, with confidence in this measuring point improving markedly.
Power & Energy · Ultrasonic flowmeter — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Ultrasonic flowmeter; the focus is transit-time ultrasonic measurement of liquid or gas flow.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking straight runs, pipe internal condition and entrained gas.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on checking straight runs, pipe internal condition and entrained gas, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means clamp-on versions avoid pipe work, minimising shutdown in revamps, which cut the workload on the site maintenance team.
Related Products
Endress+HauserProsonic Flow 93T portable
Endress+HauserProsonic Flow 91WA1 Clamp On 1Ch/1Set
Endress+HauserUltrasonic flowmeter 93W
Endress+HauserUltrasonic concentration meter D9FB
Endress+HauserUltrasonic flowmeter 9B2B
Endress+HauserUltrasonic concentration meter D9IB
Endress+HauserUltrasonic flowmeter
Endress+Hauser