Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

SFG600 Gateway

SFG600 Gateway

Gateway

The Fieldgate PAM SFG600 is a device configuration management gateway and supports HART devices via PROFINET networks. The HART devices must have a unique device TAG. The devices must be in operation with a PROFINET controller and operated via the Siemens assembly ET 200SP with the 4xl 2-wire HART analog modules with HART capabilities. During production, the Fieldgate is configured with the IP address supplied by the customer at the field network interface, and connected to the PROFINET.
Compare

Fieldbus components

Measuring Principle
Function Device configuration management gateway supports HART devices via PROFINET networks
CPU Intel Core i5 processor 7300U 2.6 GHz Dual Core
Memory SO-DIMM DDR4, 8192 MByte
Hard disk drive CFast 64 GByte MLC
Power supply 24 VDC ±25 %, SELV
Dimensions (WxHxD) 221.5 mm x 54 mm x 248.3 mm (8.72 " x 2.12" x 9.77")
Communication interface 1x Ethernet PROFINET RJ45 (ETH1)
1x Ethernet PAM Client RJ45 (ETH2)
1x Ethernet service RJ45 (IF Option 2)
System requirements PROFINET remote I/Os
Siemens ET200SP IM155-6PN HF
Order code: 6ES7 155-6AU00-0CN0
HART module with Siemens ET200SP IM 155-6PN HF
Module 4xI 2-wire HART
Order code: 6ES7 134-6TD00-0CA1
Certificates CE mark
UL
CCC

The Fieldgate PAM SFG600 is a device configuration management gateway that supports HART devices in PROFINET networks. Each HART device must use a unique device tag. The devices must be used together with a PROFINET controller and operated via a Siemens ET 200SP with four two-wire HART analog inputs. The Fieldgate is delivered with its IP address set to the address of the user's on-site network interface and is already connected to PROFINET.

Benefits

  • Industrially robust Fieldgate delivered fully configured.

  • Plug and play, simple wiring.

  • Fully automatic network scan of all HART devices connected to the Siemens ET 200SP in the PROFINET system, largely unaffected by network complexity.

  • When used with the Field Xpert SMT70 tablet, devices connect directly to the tablet as if they were right in front of you, even in large plants.

  • When used with the Field Xpert SMT70 tablet, it is the only open, FDT-based PAM system for configuring HART devices in PROFINET systems via the Siemens ET 200SP HART remote I/O interface (fully open).

  • Allows access for a remote maintenance team of up to 10 people, with up to 1024 devices connectable per PROFINET segment coupler in the system.

Application areas

The Fieldgate PAM SFG600 enables configuration of HART devices in PROFINET systems via the Siemens ET 200SP HART remote I/O interface. The Field Xpert SMT70 can connect up to 10 users and 1024 devices, quickly and simply, without scanning or network configuration.

Source:Endress+Hauserwebsite public information

Spare Parts & Accessories 1

1 spare parts · click to collapse
Order codeDescription
SFG600-Fieldgate PAM SFG600Gateway incl. 1024 HART Tags DCM Server For up to 10 Field Xpert SMT70 Clients ::HART over PN with ET200SP IM155-6 PN HFEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
All documents for this model
1 documents · click to expand
TI

Fieldgate PAM SFG600 Technical Information English

Rev. 0118 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Gateways and modems — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on Gateways and modems and the core task is converting field data into remote transmission channels.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So Gateways and modems cannot be specified generically — it calls for configured by protocol, tag count and carrier network conditions.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves configured by protocol, tag count and carrier network conditions, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is remote sites can report back, making unattended operation possible.

Food & Beverage

Food & Beverage · Gateways and modems — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted Gateways and modems properly configured on the existing plant, with the aim of converting field data into remote transmission channels.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the Gateways and modems configuration has to involve configured by protocol, tag count and carrier network conditions.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant configured by protocol, tag count and carrier network conditions, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is remote sites can report back, making unattended operation possible, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Gateways and modems — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was converting field data into remote transmission channels.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by protocol, tag count and carrier network conditions.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around configured by protocol, tag count and carrier network conditions, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — remote sites can report back, making unattended operation possible, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · Gateways and modems — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from Gateways and modems, focusing on converting field data into remote transmission channels.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The Gateways and modems specification must therefore cover configured by protocol, tag count and carrier network conditions.

Delivery Approach

Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on configured by protocol, tag count and carrier network conditions, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — remote sites can report back, making unattended operation possible, with confidence in this measuring point improving markedly.