Technical Data
ComparePressure
| Measuring Principle | |
| Characteristic | Cost-effective pressure transducer with piezoresistive sensor, and flush mounted metallic diaphragm for hygienic applications |
| Supply voltage | Analogue output: 12...30V DC, Switch output: 18...32V DC |
| Reference Accuracy | 0,5% |
| Long term stability | 0,15% of URL/year |
| Process temperature | -25°C...100°C (-13°F...212°F) 135°C for 1h (275°F for 1h) |
| Ambient temperature | -25°C...70°C (-13°F...758°F) |
| Measuring cell | 1bar...40bar (15psi...600psi) |
| Max. overpressure limit | 160bar (2320psi) |
| Process connection | Threads Tri-Clamp ISO2852 Hygienic connections |
| Communication | 4...20mA analogue PNP switch |
| Certificates / Approvals | ATEX |
| Safety approvals | SIL |
| Design approvals | EN10204-3.1 |
| Hygienic approvals | 3A |
| Specialities | switch output |
Product Overview
The following models are still in stock.
| PMP135-A1G01A1Q | Electrical connection M16; process connection Tri-clamp DN25-38; measuring range 4 bar |
| PMP135-A1G01A1S | Electrical connection M16; process connection Tri-clamp DN25-38; measuring range 10 bar |
| PMP135-A1G01A2Q | Electrical connection M16; process connection Tri-clamp DN25-38; measuring range 4 bar absolute |
| PMP135-A1G0DA1S | Electrical connection M16; process connection Tri-clamp DN25-38; measuring range 10 bar; final inspection report + 3.1 material certificate |
| PMP135-A1H01A1G | Electrical connection M16; process connection Tri-clamp DN40-51; measuring range 1 bar |
| PMP135-A1H01A1S | Electrical connection M16; process connection Tri-clamp DN40-51; measuring range 10 bar |
| PMP135-A1N01A1G | Electrical connection M16; process connection G1; measuring range 1 bar |
| PMP135-A1N01A1Q | Electrical connection M16; process connection G1; measuring range 4 bar |
| PMP135-A2N01A1G | Electrical connection NPT1/2; process connection G1; measuring range 1 bar |
| PMP135-A2N01A1Q | Electrical connection NPT1/2; process connection G1; measuring range 4 bar |
| PMP135-A4H0CA1G | Electrical connection M12; process connection Tri-clamp DN40-51; measuring range 1 bar; 3.1 material certificate |
| PMP135-A4N01A2S | Electrical connection M12; process connection G1; measuring range 10 bar absolute |
Spare Parts & Accessories 1
1 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 52022914 | Display module插接式显示模块 4-20mA, 4位红色数字显示, 霍斯曼接头DIN43650, 防护等级IP65, 压降 < 5V Cerabar T | Details |
Configurator / Comparison
Source: Endress+Hauserpublic information from the website
Manuals & Documents 5
All documents for this model5 documents · click to expand
Case Studies
Municipal Wastewater Treatment · Gauge and Absolute Pressure — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring gauge or absolute pressure to judge process state.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by turndown, overpressure protection and diaphragm material.
What We Did
We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around selected by turndown, overpressure protection and diaphragm material, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — spotting abnormal pressure early, before equipment is damaged, with routine maintenance falling noticeably.
Food & Beverage · Gauge and Absolute Pressure — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Gauge and Absolute Pressure, focusing on measuring gauge or absolute pressure to judge process state.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Gauge and Absolute Pressure specification must therefore cover selected by turndown, overpressure protection and diaphragm material.
Delivery Approach
Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on selected by turndown, overpressure protection and diaphragm material, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — spotting abnormal pressure early, before equipment is damaged, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · Gauge and Absolute Pressure — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Gauge and Absolute Pressure; the focus is measuring gauge or absolute pressure to judge process state.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by turndown, overpressure protection and diaphragm material.
Implementation
The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on selected by turndown, overpressure protection and diaphragm material, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means spotting abnormal pressure early, before equipment is damaged, which cut the workload on the site maintenance team.
Power & Energy · Gauge and Absolute Pressure — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Gauge and Absolute Pressure and the core task is measuring gauge or absolute pressure to judge process state.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Gauge and Absolute Pressure cannot be specified generically — it calls for selected by turndown, overpressure protection and diaphragm material.
Solution
The Ainstru engineering team worked through the pressure range: pressure solution matched to process pressure and temperature. The configuration involves selected by turndown, overpressure protection and diaphragm material, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is spotting abnormal pressure early, before equipment is damaged.