PMP135 pressure transmitter

PMP135 pressure transmitter
Pressure transmitter
This product has been discontinued and the replacement model is PMP23. The main purpose here is for customers to download technical documents and materials.
Compare

Pressure

Measuring Principle
Characteristic Cost-effective pressure transducer with piezoresistive sensor, and flush mounted metallic diaphragm for hygienic applications
Supply voltage Analogue output:
12...30V DC,
Switch output:
18...32V DC
Reference Accuracy 0,5%
Long term stability 0,15% of URL/year
Process temperature -25°C...100°C
(-13°F...212°F)
135°C for 1h
(275°F for 1h)
Ambient temperature -25°C...70°C
(-13°F...758°F)
Measuring cell 1bar...40bar
(15psi...600psi)
Max. overpressure limit 160bar (2320psi)
Process connection Threads
Tri-Clamp ISO2852
Hygienic connections
Communication 4...20mA analogue
PNP switch
Certificates / Approvals ATEX
Safety approvals SIL
Design approvals EN10204-3.1
Hygienic approvals 3A
Specialities switch output

Product Overview

The following models are still in stock.

PMP135-A1G01A1Q Electrical connection M16; process connection Tri-clamp DN25-38; measuring range 4 bar
PMP135-A1G01A1S Electrical connection M16; process connection Tri-clamp DN25-38; measuring range 10 bar
PMP135-A1G01A2Q Electrical connection M16; process connection Tri-clamp DN25-38; measuring range 4 bar absolute
PMP135-A1G0DA1S Electrical connection M16; process connection Tri-clamp DN25-38; measuring range 10 bar; final inspection report + 3.1 material certificate
PMP135-A1H01A1G Electrical connection M16; process connection Tri-clamp DN40-51; measuring range 1 bar
PMP135-A1H01A1S Electrical connection M16; process connection Tri-clamp DN40-51; measuring range 10 bar
PMP135-A1N01A1G Electrical connection M16; process connection G1; measuring range 1 bar
PMP135-A1N01A1Q Electrical connection M16; process connection G1; measuring range 4 bar
PMP135-A2N01A1G Electrical connection NPT1/2; process connection G1; measuring range 1 bar
PMP135-A2N01A1Q Electrical connection NPT1/2; process connection G1; measuring range 4 bar
PMP135-A4H0CA1G Electrical connection M12; process connection Tri-clamp DN40-51; measuring range 1 bar; 3.1 material certificate
PMP135-A4N01A2S Electrical connection M12; process connection G1; measuring range 10 bar absolute

Spare Parts & Accessories 1

1 spare parts · click to collapse
Order codeDescription
52022914Display module插接式显示模块 4-20mA, 4位红色数字显示, 霍斯曼接头DIN43650, 防护等级IP65, 压降 < 5V Cerabar TDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source: Endress+Hauserpublic information from the website

All documents for this model
5 documents · click to expand
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

技术资料 Cerabar T PMC131, PMP131, PMP135 Chinese

Rev. 1915 24 pages
Preview
TI

技术资料 Cerabar T PMC131, PMP131, PMP135 Chinese

Rev. 1612 24 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

Cerabar T PMC131, PMP131, PMP135 Technical Information English

Rev. 2017 28 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Gauge and Absolute Pressure — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring gauge or absolute pressure to judge process state.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by turndown, overpressure protection and diaphragm material.

What We Did

We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around selected by turndown, overpressure protection and diaphragm material, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — spotting abnormal pressure early, before equipment is damaged, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Gauge and Absolute Pressure — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Gauge and Absolute Pressure, focusing on measuring gauge or absolute pressure to judge process state.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Gauge and Absolute Pressure specification must therefore cover selected by turndown, overpressure protection and diaphragm material.

Delivery Approach

Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on selected by turndown, overpressure protection and diaphragm material, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — spotting abnormal pressure early, before equipment is damaged, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Gauge and Absolute Pressure — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Gauge and Absolute Pressure; the focus is measuring gauge or absolute pressure to judge process state.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by turndown, overpressure protection and diaphragm material.

Implementation

The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on selected by turndown, overpressure protection and diaphragm material, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means spotting abnormal pressure early, before equipment is damaged, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Gauge and Absolute Pressure — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Gauge and Absolute Pressure and the core task is measuring gauge or absolute pressure to judge process state.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Gauge and Absolute Pressure cannot be specified generically — it calls for selected by turndown, overpressure protection and diaphragm material.

Solution

The Ainstru engineering team worked through the pressure range: pressure solution matched to process pressure and temperature. The configuration involves selected by turndown, overpressure protection and diaphragm material, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is spotting abnormal pressure early, before equipment is damaged.