Technical Data
CompareContinuous / Liquids
| Measuring Principle | Absolute and gauge pressure |
| Characteristic / Application | Cost-effective pressure transducer, piezoresistive sensor with metallic measuring diaphragm for hygienic applications |
| Supply / Communication | 10…30 VDC |
| Accuracy | 0.3% |
| Long term stability | 0.2% of URL/year |
| Ambient temperature | -40…+85°C (-40…+185°F) |
| Process temperature | -10…+100°C (+14…+212°F) 135°C for 1h (275°F for 1h) |
| Process pressure / max. overpressure limit | 160 bar (2400 psi) |
| Pressure measuring range | 400 mbar…+40 bar (6...+600psi) |
| Process connection | Thread: G1, M24 |
| Process connection hygienic | DIN11851, Clamp, SMS, Varivent, Universal adapter |
| Communication | 4...20 mA IO- Link |
| Certificates / Approvals | ATEX, FM, CSA, IEC Ex, NEPSI, UK Ex |
| Design approvals | EN 10204-3.1 Final inspection report Cleaned from oil + grease Surface roughness measurement |
| Hygienic approvals | 3A, EHEDG EG1935/ 2004 |
Pressure
| Measuring Principle | Absolute and gauge pressure |
| Characteristic | Cost-effective pressure transducer, piezoresistive sensor with metallic measuring diaphragm for hygienic applications |
| Supply voltage | 10…30 VDC |
| Reference Accuracy | 0.3 % |
| Long term stability | 0.2 % of URL/year |
| Process temperature | -10 °C…+100 °C (+14 °F…+212 °F) +135 °C for 1 h (+275 °F for 1 h) |
| Ambient temperature | -40 °C…+85 °C (-40 °F…+185 °F) |
| Measuring cell | +400 mbar…+40 bar (+6 psi...+600 psi) |
| Max. overpressure limit | 160 bar (2400 psi) |
| Process connection | Threads: G1, M24 |
| Process connection hygienic | DIN11851, Clamp, SMS, Varivent, Universal adapter |
| Communication | 4...20 mA IO- Link |
| Certificates / Approvals | ATEX, FM, CSA, IEC Ex, NEPSI, UK Ex |
| Design approvals | EN 10204-3.1Final inspection report Cleaned from oil + grease Surface roughness measurement |
| Hygienic approvals | 3A, EHEDG EG1935/ 2004 |
The Cerabar PMP23 is a cost-effective, compact absolute or gauge pressure transmitter. The piezoresistive sensor with flush-mounted 316L diaphragm meets the requirements of hygienic applications. The PMP23 is available with various EHEDG and 3-A hygienic process connections, uses FDA-listed materials, complies with EC 1935/2004, has IP69 degree of protection, optional IO-Link and explosion protection approval. Devices with customer-specific measuring ranges can be ordered, up to a maximum of 40 bar.
Benefits:
-
Ultra-compact design with user-definable measuring ranges for simple, time-saving installation and setup of the instrument in the plant
-
IO-Link enables easy configuration with simple configuration tools or engineering systems, reducing cost and complexity
-
No gaskets required; the all-welded process connection provides the highest process safety
-
Made entirely of 316L for process suitability; instrument versions with IP69 protection meet washdown requirements, with high repeatability and long-term stability
-
Flexible use and low inventory costs; the PMP23 withstands CIP/SIP cleaning
-
The PMP23 meets the requirements for hygienic documentation and device traceability, e.g.: EHEDG approval, 3-A approval or Regulation (EC) 1935/2004, relevant certificates, and the manufacturer's declaration of conformity
Application areas:
The pressure transmitter measures the absolute or gauge pressure of gases or liquids.
-
Process connection: flush hygienic connection, flush threaded connection
-
Process temperature: -10...+100 °C (-40...+212 °F); +135 °C (+275 °F), max. 1 h
-
Process pressure: 400 mbar...+40 bar (6...600 psi)
-
Measuring accuracy: ±0.3 % of full scale
-
International explosion protection approval, hygienic approval
Spare Parts & Accessories 57
57 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71280307 | Hirschmann connector M16Consists of: plug connector, screw, seal, valve plug ring, adapter ring. Usage: FTI26, FTL31/FTL33, FTW33, PMC11, PMC21, PMP11, PMP21/PMP23. | Details |
| 71280349 | Hirschmann connector NPTF1/2Consists of: plug connector, screw, seal, valve plug ring, adapter ring. Usage: FTI26, FTL31/FTL33, FTW33, PMC11, PMC21, PMP11, PMP21/PMP23. | Details |
| 71114212 | M12 right-angle aviation connector, 90°自连接 可用于: M12插头 | Details |
| 52010285 | M12 connector, 90° angled, with 5 m cable适用于M12插头 带5m电缆 PVC材质,铜镀锡/ 镍锁紧螺母 | Details |
| 52006263 | Process connection | Socket for plug 4p-125V, 4A-M12M12 插头 自连接 M12转成格兰 | Details |
| 71337274 | O-ringConsisting of: 5x O-ring 15,54x2,62 FKM,FDA. Usage: FMP53, FMR43, FMR63B, PMP23, PTP33B, QMW43. | Details |
| 52022914 | Display module插接式显示模块 4-20mA, 4位红色数字显示, 霍斯曼接头DIN43650, 防护等级IP65, 压降 < 5V Cerabar T | Details |
| 52023994 | Process adapter M24 - Clamp 1 1/2"Exchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L | Details |
| 52024001 | Process adapter M24 - Clamp 1 1/2", 3.1 material certificateExchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L Inspection cert. EN10204-3.1 material | Details |
| 52023995 | Process Adapter M24 - Clamp 2"Exchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L | Details |
| 52024002 | Process adapter M24 - Clamp 2", 3.1 material certificationExchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L Inspection cert. EN10204-3.1 material | Details |
| 52023996 | Process adapter M24 Variv F DN25 PN40 316LExchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L | Details |
| 52024003 | Process adapter M24 - Variv.F DN25 PN40, 3.1 material certificateExchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L Inspection cert. EN10204-3.1 material | Details |
| 52023999 | Process adapter M24 - DIN11851 DN40Exchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L | Details |
| 52024006 | Process adapter M24 - DIN11851 DN40, 3.1 material certificateExchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L Inspection cert. EN10204-3.1 material | Details |
| 52023997 | Process adapter M24 Variv N DN40 PN40 316LExchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L | Details |
| 52024004 | Process adapter M24- Variv. N DN50 PN40, 3.1 material certificationExchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L Inspection cert. EN10204-3.1 material | Details |
| 52024005 | Process adapter M24 - DIN11851 DN50, 3.1 material certificateExchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L Abnahmepr黤zeugnis EN10204-3.1 Material | Details |
| 52026997 | Process Adapter M24 - SMS 1-1/2"Exchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L | Details |
| 52026999 | Process adapter M24 - SMS 1-1/2", 3.1 material certificateExchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316L Inspection cert. EN10204-3.1 material | Details |
Configurator / Comparison
Source: public information from the Endress+Hauser website
Manuals & Documents 10
All documents for this model10 documents · click to expand
BA Cerabar PMC11, PMC21, PMP11, PMP21, PMP23 Chinese
BA Cerabar PMP23 IO-Link Chinese
Cerabar PMC11, PMC21, PMP11, PMP21, PMP23 English
BA Cerabar PMP23 IO-Link English
TI 焊接接头、过程转接头和法兰 Chinese
TI Cerabar PMP23 Chinese
TI Cerabar PMC11, PMC21, PMP11, PMP21 Chinese
TI Weld-in adapter, process adapter and flanges English
TI Cerabar PMP23 English
TI Cerabar PMC11, PMC21, PMP11, PMP21 English
Case Studies
Municipal Wastewater Treatment · Gauge and Absolute Pressure — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring gauge or absolute pressure to judge process state.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by turndown, overpressure protection and diaphragm material.
What We Did
We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around selected by turndown, overpressure protection and diaphragm material, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — spotting abnormal pressure early, before equipment is damaged, with routine maintenance falling noticeably.
Food & Beverage · Gauge and Absolute Pressure — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Gauge and Absolute Pressure, focusing on measuring gauge or absolute pressure to judge process state.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Gauge and Absolute Pressure specification must therefore cover selected by turndown, overpressure protection and diaphragm material.
Delivery Approach
Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on selected by turndown, overpressure protection and diaphragm material, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — spotting abnormal pressure early, before equipment is damaged, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · Gauge and Absolute Pressure — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Gauge and Absolute Pressure; the focus is measuring gauge or absolute pressure to judge process state.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by turndown, overpressure protection and diaphragm material.
Implementation
The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on selected by turndown, overpressure protection and diaphragm material, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means spotting abnormal pressure early, before equipment is damaged, which cut the workload on the site maintenance team.
Power & Energy · Gauge and Absolute Pressure — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Gauge and Absolute Pressure and the core task is measuring gauge or absolute pressure to judge process state.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Gauge and Absolute Pressure cannot be specified generically — it calls for selected by turndown, overpressure protection and diaphragm material.
Solution
The Ainstru engineering team worked through the pressure range: pressure solution matched to process pressure and temperature. The configuration involves selected by turndown, overpressure protection and diaphragm material, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is spotting abnormal pressure early, before equipment is damaged.