Technical Data
CompareContinuous / Liquids
| Measuring Principle | Absolute and gauge pressure |
| Characteristic / Application | Pressure transmitter with metal membrane for accurate measurement in liquids or gases. Designed for hygienic applications. |
| Supply / Communication | 4...20 mA, 4...20 mA HART |
| Accuracy | Standard 0.1% Platinum 0.075% |
| Long term stability | 0.1% of URL/year 0.2% of URL/ 5 years 0.25% of URL/ 10 years |
| Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
| Process temperature | -40°C...+130°C (-40°F...+266°F) -20°C...+200°C (-4°F...+392°F) |
| Pressure measuring range | 400 mbar...100 bar (6 psi...1450 psi) |
| Process connection | Thread: G1/2...G2, R1/2, MNPT3/4...MNPT2,FNPT1/2 Flange: DN25...DN80, NPS 1"...3" |
| Process connection hygienic | Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent SMS DRD Universal adapter |
| Communication | 4...20 mA, 4...20 mA HART Bluetooth® wireless technology and app (optional) |
| Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IECEx, INMETRO, NEPSI, UK Ex |
| Hygienic approvals | CoC ASME-BPE 3A EHEDG |
| Marine approval | GL/ ABS/ LR/ BV/ DNV |
| Drinking water approvals | NSF |
Pressure
| Measuring Principle | Absolute and gauge pressure |
| Characteristic | Pressure transmitter with metal membrane for accurate measurement in liquids or gases. Designed for hygienic applications. Available with diaphragm seals. |
| Supply voltage | 4...20mA HART 11,5...45V DC (Non Ex): Ex ia: 12...30V DC |
| Reference Accuracy | Standard 0.1% Platinum 0.075% |
| Long term stability | 0.1% of URL/year 0.2% of URL/ 5 years 0.25% of URL/ 10 years |
| Process temperature | -40°C...+130°C(-40°F...+266°F) -20°C...+200°C(-4°F...+392°F) |
| Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
| Measuring cell | 400 mbar...100 bar (6 psi...1450 psi) |
| Smallest calibratable span | 20 mbar (0.3 psi) |
| Vacuum resistance | 50 mbar (0.725 psi) |
| Max. Turn down | 20:1 |
| Process connection | Thread: G1/2...G2, R1/2, MNPT3/4...MNPT2,FNPT1/2 Flange: DN25...DN80, NPS 1"...3" |
| Process connection hygienic | Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent SMS DRD Universal adapter |
| Material process membrane | 316L |
| Material gasket | None, diaphragm welded |
| Material housing | 316L hygiene |
| Communication | 4...20 mA 4...20 mA HART 4...20 mA IO-Link |
| Certificates / Approvals | ATEX, FM, CAN/US, IECEx, INMETRO, NEPSI, UK Ex |
| Design approvals | EN10204-3.1 NACE MR0175 |
| Hygienic approvals | CoC ASME-BPE 3A EHEDG |
| Drinking water approvals | NSF/ANSI 61 ACS KTW |
Cerabar PMP43 – hygienic pressure transmitter
Particularly compact, highly reliable and ideal for demanding hygienic applications
Advantages
Excellent ease of use thanks to easy setup and operation via guided wizards and an intuitive touch display
Increased process and product safety through configuration integrity - the checksum algorithm (CRC) ensures that safety-related parameters remain unchanged
Increased productivity through traceable and documented on-demand verification without interrupting the process, and continuous monitoring of process anomalies or impulse line blockage using Heartbeat Technology
360-degree hygienic design and IP69 degree of protection enable efficient cleaning and prevent contamination
Documented compliance through certified hygienic design and verified material consistency and traceability
Field of application
The Cerabar PMP43 is a pressure transmitter and part of the Compact Line. This product family was developed specifically for hygienic applications and combines a compact design with full performance. The proven technology is suitable for measuring and monitoring absolute and gauge pressure in liquids and gases. Thanks to the compact sensor design and small process connections, the device scales flexibly and can be installed in confined spaces.
The Cerabar PMP43 is used to measure pressure and level in pipes as well as process tanks and storage tanks.
Configurator / Comparison
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserpublic information from the website
Manuals & Documents 12
All documents for this model12 documents · click to expand
BA Cerabar PMP43 Chinese
BA Cerabar PMP43 Chinese
BA Cerabar PMP43 Chinese
BA Cerabar PMP43 English
BA Cerabar PMP43 English
BA Cerabar PMP43 English
TI 焊接接头、过程转接头和法兰 Chinese
TI Cerabar PMP43 Chinese
TI Cerabar PMP43 Chinese
TI Cerabar PMP43 Chinese
TI Weld-in adapter, process adapter and flanges English
TI Cerabar PMP43 English
Case Studies
Municipal Wastewater Treatment · Gauge and Absolute Pressure — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring gauge or absolute pressure to judge process state.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by turndown, overpressure protection and diaphragm material.
What We Did
We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around selected by turndown, overpressure protection and diaphragm material, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — spotting abnormal pressure early, before equipment is damaged, with routine maintenance falling noticeably.
Food & Beverage · Gauge and Absolute Pressure — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Gauge and Absolute Pressure, focusing on measuring gauge or absolute pressure to judge process state.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Gauge and Absolute Pressure specification must therefore cover selected by turndown, overpressure protection and diaphragm material.
Delivery Approach
Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on selected by turndown, overpressure protection and diaphragm material, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — spotting abnormal pressure early, before equipment is damaged, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · Gauge and Absolute Pressure — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Gauge and Absolute Pressure; the focus is measuring gauge or absolute pressure to judge process state.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by turndown, overpressure protection and diaphragm material.
Implementation
The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on selected by turndown, overpressure protection and diaphragm material, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means spotting abnormal pressure early, before equipment is damaged, which cut the workload on the site maintenance team.
Power & Energy · Gauge and Absolute Pressure — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Gauge and Absolute Pressure and the core task is measuring gauge or absolute pressure to judge process state.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Gauge and Absolute Pressure cannot be specified generically — it calls for selected by turndown, overpressure protection and diaphragm material.
Solution
The Ainstru engineering team worked through the pressure range: pressure solution matched to process pressure and temperature. The configuration involves selected by turndown, overpressure protection and diaphragm material, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is spotting abnormal pressure early, before equipment is damaged.